Hot Sale ABC Cable Aluminum Aerial Bundle Cables Caai Overhead Cable Manufacturer
| Price | $10.00 |
|---|---|
| Min Order | 1000 Meters |
| Availability | In Stock |
| Shipping From | Henan, China |
| Popularity | 461 people viewed |
Model NO.:
ABC cable
Type:
Insulated
Conductor Type:
Stranded
Application:
Overhead
Conductor Material:
Aluminum
Sheath Material:
PVC
Insulation Material:
XLPE
Material Shape:
Round Wire
Range of Application:
Overhead, Power Station
Certification:
ISO9001, CE, CCC, RoHS, VDE
Samples:
Free
OEM , ODM:
Ok
Colour:
Could Be Customized Color
Logo:
According to Your Requirement
Warranty:
100% Qualified
Factory or No:
Factory
Advantages:
High Quality, Competitive Price, Fast Delivery
No. of Cores:
One Core or Multi-Cores
Trademark:
ZML
Transport Package:
Wooden Reel
Specification:
ABC
Origin:
China
Product Description
Hot Sale ABC Cable 0.6/1kv Aluminum Aerial Bundle Cables Caai Overhead Cable Manufacturer
Applications
Primarily used for overhead service application such as street lighting,outdoor lighting,and temporary service for construction, To be used at voltage of 600V to 2200V phase-to-phase or less at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for cross liked polyethylene insulated conductors.
Standards
We could produce the cable according to many standards: ICEA S-76-474,
ICEA S-95-658,ICEA S-61-402,ICEA S-66-524.NFC 33. IEC
we will do our best to meet your requirements
Specification
- Phase conductor: Aluminum wire, 1350-H19
- Neutral Conductor : Aluminum wire 1350-H19, All Alloy Aluminum Conductor 6201, Aluminum Conductor Steel Reinforced
- The material of insulation: XLPE,PE,PVC
- The Voltage: 600V-2200V Packaging: Iron Or Wooden Drum
Primarily used for 120 volt overhead service applications such as street lighting, outdoor lighting, and temporary service for construction.
| Nominal cross section | Neutral core | Phase core | weight (kg/km) | Allowable ampacity (A) | |||||
| AAC | LBS | AAC | Insulation thickness (mm) | XLPE | PE | ||||
| NO | diameter (mm) | NO | diameter (mm) | ||||||
| 1*6AWG+1*6AWG | 7 | 1.56 | 563 | 1 | 4.11 | 1.14 | 92 | 85 | 70 |
| 1*6AWG+1*6AWG | 7 | 1.56 | 563 | 7 | 1.56 | 1.14 | 94 | 85 | 70 |
| 1*4AWG+1*4AWG | 7 | 1.96 | 881 | 1 | 5.19 | 1.14 | 139 | 115 | 90 |
| 1*4AWG+1*4AWG | 7 | 1.96 | 881 | 7 | 1.96 | 1.14 | 141 | 115 | 90 |
| 1*2AWG+1*2AWG | 7 | 2.47 | 1350 | 7 | 2.47 | 1.14 | 216 | 150 | 120 |
| 1*1/0AWG+1*1/0AWG | 7 | 3.12 | 1990 | 19 | 1.89 | 1.52 | 347 | 205 | 160 |
Used to supply power, usually from a pole-mounted transformer, to the user's service head where connection to the service entrance cable is made
AWG or kcmil | Bare Neutral Messenger | Phase Conductor | Weight kg/km | Allowable Ampacities(A) | |||||
AAC | Rated Strength lbs. | AAC | Insul. Thick. mm | XLPE | PE | ||||
NO. | Dia.mm | NO. | Dia.mm | ||||||
2*6AWG+1*6AWG | 7 | 1.56 | 563 | 1 | 4.11 | 1.14 | 146 | 85 | 70 |
2*6AWG+1*6AWG | 7 | 1.56 | 563 | 7 | 1.56 | 1.14 | 150 | 85 | 70 |
2*4AWG+1*4AWG | 7 | 1.96 | 881 | 1 | 5.19 | 1.14 | 219 | 115 | 90 |
2*4AWG+1*4AWG | 7 | 1.96 | 881 | 7 | 1.96 | 1.14 | 224 | 115 | 90 |
2*2AWG+1*2AWG | 7 | 2.47 | 1350 | 7 | 2.47 | 1.14 | 338 | 150 | 120 |
2*1/0AWG+1*1/0AWG | 7 | 3.12 | 1990 | 7 | 3.12 | 1.52 | 544 | 205 | 160 |
2*1/0AWG+1*1/0AWG | 7 | 3.12 | 1990 | 19 | 1.89 | 1.52 | 545 | 205 | 160 |
2*2/0AWG+l*2/0AWG | 7 | 3.5 | 2510 | 7 | 3.5 | 1.52 | 671 | 235 | 185 |
2*3/0AWG+l*3/0AWG | 19 | 2.39 | 3310 | 19 | 2.39 | 1.52 | 830 | 275 | 215 |
2*4/0AWG+l*4/0AWG | 19 | 3.25 | 4020 | 19 | 3.25 | 1.52 | 1476 | 315 | 245 |
2*336.4+1*336.4 | 19 | 3.38 | 6146 | 19 | 3.38 | 2.03 | 1649 | 420 | 325 |
AWG or kcmil | Bare Neutral Messenger | Phase Conductor | Weight kg/km | Allowable Ampacities(A) | |||||
ACSR | Rated Strength lbs. | AAC | Insul. Thick. mm | XLPE | PE | ||||
No. | Dia. mm | No. | Dia. mm | ||||||
3*6AWG+1*6AWG | 1,6 | 1.68 | 1190 | 1 | 4.11 | 1.14 | 221 | 75 | 60 |
3*6AWG+1*6AWG | 1,6 | 1.68 | 1190 | 7 | 1.56 | 1.14 | 227 | 75 | 60 |
3*4AWG+1*4AWG | 1,6 | 2.12 | 1860 | 1 | 5.19 | 1.14 | 331 | 100 | 80 |
3*4AWG+1*4AWG | 1,6 | 2.12 | 1860 | 7 | 1.96 | 1.14 | 338 | 100 | 80 |
3*2AWG+1*2AWG | 1,6 | 2.67 | 2850 | 7 | 2.47 | 1.14 | 511 | 135 | 105 |
3*1/0AWG+1*1/0AWG | 1,6 | 3.37 | 4380 | 19 | 1.89 | 1.52 | 824 | 180 | 140 |
3*2/0AWG+l*2/0AWG | 1,6 | 3.78 | 5310 | 19 | 2.13 | 1.52 | 1015 | 205 | 160 |
3*3/0AWG+l*3/0AWG | 1,6 | 4.25 | 6620 | 19 | 2.39 | 1.52 | 1254 | 235 | 185 |
3*4/0AWG+l*4/0AWG | 1,6 | 4.77 | 8350 | 19 | 2.68 | 1.52 | 1554 | 275 | 210 |
3*336.4+1*336.4 | 1,18 | 3.47 | 8680 | 19 | 3.38 | 2.03 | 2321 | 370 | 280 |
3*336.4+l*4/0AWG | 1,6 | 4.77 | 8350 | 19 | 3.38 | 2.03 | 2221 | 370 | 280 |
1.Are you a manufacturer or trading company?
We are a professional manufacturer.We can control your order from the firstbeginning to the last.
Welcome to visit us.We'll pick you up in Zhengzhou
2. How can I get a sample to test your quality?
The samples are free for you.New clients are expected to pay for the courier
cost.
3.What's your Minimum Order Quantity?
Normally 1000m.How ever the cable is very heavy.
You'd better order a suitable quantity to avoid the high freight.
Sea transportation is the best option.
4.Can I get a discount?
It depends on your quantity,We can make a discount and afford the freight.
Pls kindly contact us.
5. Does your company accept OEM production?
Yes, could print your company name we even custom the quality card to
promote your company.
- Similar Products
$99.00
5000 Meters (MOQ)
4-Core 0.75mm ² Water Pump Cable Equipment Connection Cable
Haiyan Hetai Cable Co., Ltd
$200.00
5000 Meters (MOQ)
Flexible Rvv 7core Power Wire Multi-Core Machine Equipment Line Full Copper Cable
Haiyan Hetai Cable Co., Ltd
$10.00
6000 Feet (MOQ)
Nmd 2c-10 Cu 300V Orange Nmd90 Cable
Hebei Huatong Wires & Cables Group Co., Ltd.
$10.00
1 Meter (MOQ)
Overhead Crane Electric Power Supply System Bus Bar
HENAN NYBON MACHINERY CO., LTD.