IEC Standard Overhead Fuse Cutout Porcelain Model for Power Transformers
| Price | $50.00 |
|---|---|
| Min Order | 100 Pieces |
| Availability | In Stock |
| Shipping From | Zhejiang, China |
| Popularity | 498 people viewed |
Model NO.:
YNC1-24
Breaking Capacity:
High
Type:
Current Fuse
Usage:
High Voltage
Shape:
Dropout
Fusing Speed:
K
Fusing Device:
Fuse Element
Rated Voltage:
24kv-33kv
Trademark:
YN
Transport Package:
Carton&Pallet or Wooden Case
Specification:
100A/200A
Origin:
China
HS Code:
85351000
Product Description
IEC Standard Overhead Fuse Cutout Porcelain Model for Power Transformers
Drop-out fuse cutout and load switching fuse cutout are of outdoor used high voltage protective device. To be connected with incoming feeder of distribution transformer or distribution lines, it mainly protect transformer or lines from short circuit and overload, and on/off loading, current. Drop-out fuse cutout is composed of insulate insulator supports and fuse tube, static contacts is fixed on two sides of insulator support and moving contact is installed on two ends of fuse tube. Fuse tube is composed of inside arc-extinguishing tube. Outer phenolic compound paper tube or epoxy glass tube, load switching fuse cutout provides enforced elastic auxiliary contacts and arc-extinguishing enclosure switching on-off loading current.
At normally working via fuse link tightened the fuse tube is fixed to form up of close position. In case system occur faults, fault current result result in fuse melt immediately and take piece electric are, which let arc-extinguishing tube being heated and explode a lot of gas, This will produce high pressure and below of the are along with tube. After fuse link melt moving contact has no tightened strength again, mechanism is locked and fuse tube drop out, Cutout now is in open position. When it needs to switch off during cutout loading, operator shall via insulating operating bar pull the moving contact, at its beginning main contact and auxiliary static contact is contacted still, Whiling pulling the auxiliary contact is separated between auxiliary contacts there occur electric arc and the arc will be lengthened in arc-extinguishing enclosure gap and meanwhile arc-extinguishing explode gas to blow off the arc during current passing zero.
Main Technical Parametes
Drop-out fuse cutout and load switching fuse cutout are of outdoor used high voltage protective device. To be connected with incoming feeder of distribution transformer or distribution lines, it mainly protect transformer or lines from short circuit and overload, and on/off loading, current. Drop-out fuse cutout is composed of insulate insulator supports and fuse tube, static contacts is fixed on two sides of insulator support and moving contact is installed on two ends of fuse tube. Fuse tube is composed of inside arc-extinguishing tube. Outer phenolic compound paper tube or epoxy glass tube, load switching fuse cutout provides enforced elastic auxiliary contacts and arc-extinguishing enclosure switching on-off loading current.
At normally working via fuse link tightened the fuse tube is fixed to form up of close position. In case system occur faults, fault current result result in fuse melt immediately and take piece electric are, which let arc-extinguishing tube being heated and explode a lot of gas, This will produce high pressure and below of the are along with tube. After fuse link melt moving contact has no tightened strength again, mechanism is locked and fuse tube drop out, Cutout now is in open position. When it needs to switch off during cutout loading, operator shall via insulating operating bar pull the moving contact, at its beginning main contact and auxiliary static contact is contacted still, Whiling pulling the auxiliary contact is separated between auxiliary contacts there occur electric arc and the arc will be lengthened in arc-extinguishing enclosure gap and meanwhile arc-extinguishing explode gas to blow off the arc during current passing zero.
Main Technical Parametes
| Type | Rated voltage (kv) | Rated current (A) | Breaking current (A) | Impulse voltage (BIL) | Powerfrequency withstand voltage | Leakage distance (MM) |
| YNC1-24/100 | 30-33 | 100 | 8000 | 145 | 60 | 650 |
| YNC1-24/200 | 30-33 | 200 | 10000 | 145 | 60 | 650 |
- Similar Products
$0.05
2000 Pieces (MOQ)
1A 2A 5A 10A 15A 16A 250V Thermal Fuse for Rice Cooker
Dongguan Tianrui Electronics Co., Ltd.
Negotiable
20 Pieces (MOQ)
DC700V 2A-100A Energy Storage Fast Fuse with Ar Function
ZHEJIANG FUERZI ELECTRIC TECHNOLOGY CO., LTD.
$2.48
100 Pieces (MOQ)
500V 125A IEC CE Fuse Uesd in Low Voltage System
Gandian Lightning Protection Electric Co., Ltd.