Negotiable
1 Piece (MOQ)
ID200mm Dac HPLC Column
Good Science (Tianjin) Instrument Technology Co., Ltd.
Swipe or use the arrows to view product images.
Inscinstech Laboratory Instrument Pilot Scale Fplc Chromatography System Protein Purification System (Unique AutoPure Pilot600)
| Price | Negotiable |
|---|---|
| Min Order | 1 Piece |
| Availability | In Stock |
| Shipping From | Jiangsu, China |
| Popularity | 1193 people viewed |
Model NO.:
Unique AutoPure pilot600
After-sales Service:
1 Year
Warranty:
1 Year
Appliance:
Biochemistry
Certification:
CE, ISO
Mobile Phase:
Liquid
Chromatography Type:
Liquid Chromatography
Chromatographic Column Type:
Preparative Column
Control System:
Unique Cdsystem
Velocity Range:
4-600ml/Min
Weight:
60kg
Trademark:
Inscinstech
Transport Package:
Flight Case
Specification:
600X500X850mm
Product Description
| Main system size | L*W*H 600x500x850mm | |
| Main system weight | 65kg | |
| Control system | Unique CDSystem | |
| Enclosure rating | IP54 | |
| Electricity supply | 100~ 240 V, 50 ~ 60 Hz | |
| Working environment | Temperature: 4ºC~35ºC, Relative Humidity: 20%~95%, no condensation | |
| System pump (Dual pump system) | A/B pump Flow rate range: 4~600ml/min (2- pump packing mode: 1~ 1200ml/min) Eligibility range: 5%~95% Pressure range: 0~ 2MPa (20bar, 290 psi) Viscosity: 0.7~10 cp | |
UV detector | 280nm fixed wavelength detector LED light source, lifespan>8000h Detection range: - 6~ +6AU Linearity: between±2%@0 ~ 2AU Wavelength Accuracy: ±1nm Wavelength Repeatability: ±0.1nm Noise:±2*10 - 5AU | DAD full spectrum direct reading detector, 200~400nm variable dual wavelength. Wavelength Accuracy: ±1nm Wavelength Repeatability: ±1 nm Noise: ±4*10 - 5AU (@254nm,1S) |
| Optical fiber conduction, external flow cell, avoid light source temperature affecting the activity of protein samples, double beam design with high stability. Standard flow cell: 2mm optical diameter, 50μl flow cell volume, maximum pressure resistance 2Mpa | ||
| Conductivity detector | Detection range: 0.1mS/cm ~ 999.9mS/cm Detection cell volume: 20μl Accuracy: ±3% or 0.2mS/cm built-in temperature sensor, automatic compensation calibration | |
| Temperature detector | Temperature range: 0 ~99ºC; Temperature Accuracy:± 2ºC 2ºC ~50ºC | |
| pH detector | Detection range:2~ 12;Accuracy: ±0.15 | |
| Inlet options | 4 inlets for single pump A total of 8 inlets of double pumps Expandable to 12 inlets | |
| Outlets options | Maximum 8 outlets | |
| Column valve | Single column | |
| Bubble trap | Effectively remove air bubbles in flowpath, optional online or offline | |
| Mixer | Mixing chamber volume: 12ml | |
| Bubble sensor | Support up to 3 | |
| Pressure sensor | One after each pump(A,B), one before the column, one after the column, a total of four, detection range is 0- 2MPa | |