Model NO.:
JLSZW-10
Application:
Instrument
Type:
Combined Transformer
Phase:
Three
Operation Condition:
Outdoor
Usage:
Measurement
Rated Voltage:
11kv
Installation Method:
Withdrawable
Rated Frequency:
50/60Hz
Material:
Resin
Rated Current:
630A
Customize:
Yes
Model No.:
Jlszw-10
Size:
Medium
Brand Name:
Shengsu
Coil Number:
2
Coil Structure:
Copper
Mechanical Life:
10000 Times
Ambient Temperature:
-15-40
Power Factor:
Cos=0.8(Lagging)
Altitude:
≤1000m
Trademark:
SHENGSU ELECTRIC CO., LTD
Transport Package:
Cartoon
Specification:
pcs
Origin:
China
Product Description
This series of metering boxes are improved on the basis of similar products. They are suitable for electric energy measurement in outdoor AC power systems with rated frequency of 50Hz, rated voltage of 10kV and 6kV. It is an ideal substitute for old-fashioned oil-immersed products. This series of products is composed of two parts: voltage and current combined transformer and measuring instrument box. The transformer is equipped with two independent voltage and current transformers, which are divided into phases A and C. The outer wall of the combined transformer is equipped with power and reactive watt-hour meters, as well as a joint junction box for testing, and the meter box is used during operation. Covered to prevent electricity theft. 
Rated voltage kV1224

Rated insulation level
Power frequency withstand voltage (1min)kV42/4865/79
Lighting impulse withstand voltage (peak)kV75/85125/145
Rated current A630-4000630-3150
Rated short-time withstand current kA25-4025-40
Rated peak withstand current kV63-10063-100
Rated short-circuit breaking current kA25-4025-40
Rated short-circuit making current kA63-10063-100
Rated frequency Hz5050
Secondary circuit rated short-time withstand voltage(1min) kV22
Secondary circuit rated voltage VDC110,220 / AC110,220DC110,220 / AC110,220
 

Using the environment conditions


Ambient air humidity: cap + 40 ºC, lower limit - 15 ° ºC
Altitude: < 1000 m (if need higher elevation, the rated insulation level increase)