Swipe or use the arrows to view product images.
Kyn28A-12 High Quality Armored Removable AC Metal Electric Enclosed Switchgear
| Price | $50000.00 |
|---|---|
| Min Order | 1 Piece |
| Availability | In Stock |
| Shipping From | Zhejiang, China |
| Popularity | 443 people viewed |
Model NO.:
KYN28A-12
Type:
Neutral Point Grounding Resistor Cabinet for Trans
Installation:
Fixed
Structure:
Cabinet
Customization:
Acceptable
Language:
Chinese, English, Russian, etc
Loading Port:
It Depends
Rated Voltage:
6-66kv
Frequency:
50Hz
Transport Package:
Wooden Case or Others
Specification:
As required
Origin:
China
Product Description
Introduce:
Usage Environment:
1. Suitounding airtemperature:Upper limit+40ºC,lower limit -15ºC.
2. Maximum altitude of equipment installation site:1000m.
3. Environmental humidity daily average relative humidity ≤95%, monthly average relative humidity≤90% .
4. Earthquake intensity not exceeding 8 degrees.
5. The suitounding air should not be significantly polluted by corrosive or flammable gases, water vapor etc.
6. No serious pollution or frequent severe vibration.
Technical Performance Parameter Table
| Serial Number | Project | Company | Numerical Value |
| 1 | Rated Voltage | kv | 12 |
| 2 | Power Frequency withstand Voltage | kv | Interphase & Ground:42,Fracture:48 |
| 3 | Lightning Impluse | Kv | Interphase & Ground:75,Fracture:85 |
| 4 | Rated Frequency | Hz | 50 |
| 5 | Rated Current | A | 630,1250,1600,2000,3150 |
| 6 | Rated Current of Main Busbar | A | 630,1250,1600,2000,3150 |
| 7 | Rated Short-circuit Open Circuit Current | KA | 25,31.4,40 |
| 8 | Rated Short-time Withstand Current of the Main Circuit | KA/4S | 16,20,25,31.5,40 |
| 9 | Rated Short-time Withstand Current of the Grounding Circuit | KA/2S | 13.9,17.4,21.8,27.4,34.8 |
| 10 | Rated Peak Withstand Current | A | 40,50,63,80,100 |
| 11 | Protection Level | IP4X |
Extemal Dimensions
| A(mm) | Main Switch Rated Current 1250A | 800 |
| Main Switch Rated Current 1600-3150A | 1000 | |
| B(mm) | 2300 | |
| C(mm) | Cable Inlet and Outlet Lines | 1500 |
| Overhead Incoming Lines | 1660 | |
| Weight(kg) | 700-1200 |
Cabinet Type
| Cabinet Number | Feature Description | Dimensions(width*depth*height)mm |
| I Model | Cable Inlet and Outlet,Main Switch Rated Current 1250A | 800*1500*2300 |
| II Model | Cable Inlet and Outlet,Main Switch Rated Current 1600-3150A | 1000*1500*2300 |
| III Model | Overhead Incoming and Outgoing Lines,Main Switch Rated Current 1250A | 800*1660*2300 |
| IV Model | Overhead Incoming and Outgoing Lines,Main Switch Rated Current 1600-3150A | 1000*1660*2300 |
- Similar Products
$300.00
1 Piece (MOQ)
Power Transmission Equipment Cooling Parts
JIANGSU TENGQI ELECTRIC POWER TECHNOLOGY CO., LTD.
Negotiable
1 Piece (MOQ)
Oil Type Three Phase Shunt Reactor W/on-Load Tap Changer 20mva 132kv
Ningbo Ville Electric Co., Ltd.
$100000.00
1 Piece (MOQ)
132kv 20mva Mobile Transformer Substation
Wenzhou Rockwill Electric Co., Ltd.
$200.00
10 Pieces (MOQ)
PTFE Nozzles for Sf6 Switchgear or Circuit Breaker
Starrysky Industrial (Shanghai) Co., Ltd.