Menu
Global B2B sourcing platform
Verified suppliers and manufacturers

Manufacturer Residual Current Magnetic Type B Rccd RCCB for AC EV Charger

Price $55.00
Min Order 60 Pieces
Availability In Stock
Shipping From Jiangsu, China
Popularity 294 people viewed
Model NO.:
AG-VDF-2B-50A
Breaking Capacity:
Low Voltage Circuit Breakers
Operation:
Electric Type
Speed:
Normal Type Circuit Breaker
Arc-extinguishing Medium:
SF6
Installation:
Insert
Structure:
ELCB
Poles Number:
1
Type:
Circuit Breaker
Function:
RCCB
Certification:
CE, CB, CCC
Mode:
Electro-Magnetic Type
Rated Voltage:
AC 230(240)/400(415)
Electro-Mechanical Endurance:
4000 Cycle
Protection:
IP20
Terminal Connection Height: 19mm:
19mm
Connection Terminal:
Screw Terminal
Supply Ability:
10000 Pole/Poles Per Month
Trademark:
AEGEN
Transport Package:
Carton
Specification:
36*78*81mm
Origin:
China
HS Code:
8538900000
Product Description
Product Description

Residual current circuit breakers (RCCBs) 

This device is essentially a  attached to it. So basically it will only break the circuit when there is a leakage current flowing to earth. The tripping time is such as to minimise the risk to human life.

RCCBs usually have a fault making and . This means that they can handle a fault of 1 kA on their own if it is a fault to earth.

Type B residual current device disconnects the power if the earth leakage current is detected as dangerous. If the earth leakage current is equal to or less than 10mA, then the Type B residual current devices would not trip because this current amount is not dangerous. The electric car will continue to get charging without any interruption. The Type B residual current devices will immediately trip the circuit and disconnect the power supply for higher currents. Like this, Type B residual current devices will protect the circuits from danger.
                                                                        Technical Data
Model:AG-VDF-2B-63A
Pole No.:1P+N, 3P+N
Rated current(A):16A,25A, 32A, 40A, 63A,80A,100A 
Rated working voltage(I n):30, 100, 300, 500mA
Rated voltage(V):AC 230(240)/400(415)
Rated frequency(Hz):50/60
Rated making and breaking capacity:500(In=25A,32,40A), 630(In=63A)
Rated conditional short-circuit current Inc:10000A
Rated conditional residual short-circuit Current I c:10000A
Rated residual non operating current I no:0.5I n
Residual operating current range:0.5I n~I n
Operating time:≤0.3s
Type:A and AC type
Rated short-circuit breaking capacity:10000A
Mechanical life:2000 times
Degree of protection:IP20
Products name:Type B RCD | Type B RCCB | Detection residential RCCB 