Swipe or use the arrows to view product images.
Me537 Power Analyzer Rogowski Coil Modbus TCP Panel Analyzer 32GB Data Logger Power Quality Analyzer
| Price | $200.00 |
|---|---|
| Min Order | 1 Piece |
| Availability | In Stock |
| Shipping From | Shanghai, China |
| Popularity | 300 people viewed |
Model NO.:
ME537
After-sales Service:
3 Year
Warranty:
3 Year
Display:
Digital
Installation:
Panel Mounting
Usage:
Multi-Functional Energy Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Reactive Energy Meter, Maximum Demand Meter, Panel Analyzer
Electric Equipment:
Three-phase Four-wire
Theory:
Electronic Meter
Power Meter Connection:
Terminal
Measured Signal:
333mv CT, Rogowski Coil
Type:
Power Quality Analyzer
Certification:
RoHS, ISO, CE
Customized:
Customized
Input Type:
External CT(333mv Only), Rogowski Coil
Power:
85 - 305VAC/100 - 430VDC
Storage:
32 GB SD Card
Poles Description:
Three Phase and Single Phase
Device Application:
Power Analysis, Power Measurement, Power Quality a
Sampling Rate:
8K Samples Per Second
Harmonic:
50th Max
Communication:
Modbus TCP, RJ45
Primary Current Range:
Adjustable From 0.1A to 9999A
Voltage:
Cat III 600V
Frequency Range:
50/60Hz
Display Screen:
3.5 Inch IPS Display
Trademark:
MEATROL
Transport Package:
Poly Bag and Stand Export Carton
Specification:
96*96*94mm
Origin:
China
HS Code:
9030331000
Product Description
World-famous manufacturer
Three major production bases in Shanghai, Chongqing, and Zhejiang
Looking forward to in-depth communications, project cooperation, and exclusive agency
Three major production bases in Shanghai, Chongqing, and Zhejiang
Looking forward to in-depth communications, project cooperation, and exclusive agency
- Product description
- Support systems of single-phase and three-phase. It can measure multiple electrical parameters such as current, voltage, power factor, power, energy, and power quality parameters including harmonic, unbalance degree, voltage swell and voltage dip, etc.
- In addition to the measurement function, ME537 is equipped with various records, such as waveform records and programmable interval measurement value records. To store and record data, it is internally embedded 32 GB memory card.
- Standard RJ45 Ethernet and RS485 communication interfaces, compatible with various configuration systems through standard Modbus TCP and Modbus RTU protocols, transmit real-time electrical parameters collected by the front-end to the system data center
- General parameters
| Product name | ||
| Model No. | ME537 | |
| Type | Three phase power quality analyzer | |
| Application field | ||
| Application field | Power analysis, Power measurement, Power quality analysis | |
| Wiring mode | ||
| Wiring system | 3P4W_4CT 3P4W_3CT 3P3W_3CT 3P3W_2CT 1P3W 1P2w | |
| Current sensor | Rogowski coil Voltage-output current clamp | |
| Voltage access | Direct access Connected through voltage transformer | |
| Storage | ||
| Type | TF card | |
| Capacity | 32GB | |
| Data export | U disk export (U disk file is FAT32 system) | |
| Communication | ||
| Interface | RJ45- Ethernet | RS485 |
| Protocol | Modbus-TCP | Modbus-RTU |
| Power Supply | ||
| Power | 85 - 305VAC/100 - 430VDC | |
| Maximum power consumption | 5VA | |
| Display | ||
| Size | 3.5 inch | |
| Type | IPS display | |
| Resolution ratio | 480*800 | |
| Machinery | ||
| Dimention | 96*96*94mm | |
| Weight | 850g | |
| Environment | ||
| Working environment | Temperature-20ºC~+55ºC, Humidity below 90% RH | |
| Storage environment | Temperature-40ºC~+70ºC, Humidity below 95% RH(non-condensing) | |
| Altitude | ≤2km | |
| Measurement category | CAT III 600V | |
| IP code | IP30 | |
- Measurement parameters
| Real-time measurement data | |
| Voltage | Phase voltage: Phase ABC N phase to ground voltage Line voltage: UAB, UBC, UCA Voltage peak coefficient: Phase ABC Voltage peak: Phase ABC |
| Current | Phase current: Phase ABCN Current peak coefficient: Phase ABC K Factor: Phase ABC |
| Frequency | Line frequency |
| Power | Active power: Phase ABC and total Reactive power: Phase ABC and total Apparent power: Phase ABC and total |
| Power factor | Phase ABC and total |
| Fundamental harmonic power factor | Phase ABC and total |
| Electrical energy | Active Energy: Phase ABC and total (import / export) Reactive energy: Phase ABC and total (import / export) Apparent Energy: Phase ABC and total CO2 emissions |
| Harmonic measurement data | |
| Voltage harmonics | THD (Total harmonic percentage), TOHD (Odd total harmonic percentage), TEHD (Even total harmonic percentage), phase ABC 1-50th harmonic percentage, phase ABC 1-50th harmonic voltage value |
| Current harmonics | THD (Total harmonic percentage), TOHD (Odd total harmonic percentage), TEHD (Even total harmonic percentage), phase ABC 1- 50th harmonic percentage, phase ABC 1-50th harmonic current value |
| Waveform | |
| Voltage waveform | Phase ABC voltage waveform or UAB, UBC, UCA line voltage waveform |
| Current waveform | Phase ABC current waveform |
| Phase angle | |
| Voltag pehase angle | Phase ABC |
| Current pehase angle | Phase ABC |
| Phase angle between voltage and current | Phase ABC |
| Unbalance | |
| Unbalance | Voltage unbalance, current unbalance |
| Demand | |
| Power demand and peak demand | Phase ABC active power and total power, phase ABC reactive power and total power, phase ABC apparent power and total power |
| Current demand and peak demand | Phase ABC |
- Parameter accuracy
| Parameter | Type | Description |
| Voltage | Channel input voltage range | 0-600VAC |
| Measurement range | 0-600VAC | |
| Measurement accuracy | 0.2% | |
| Current | Channel input voltage range | 0-420mVAC |
| Measurement range | Different current sensors have different measuring ranges | |
| Measurement accuracy | 0.2%+ Accuracy of current sensor | |
| Frequency | Measurement range | 45Hz-65Hz |
| Measurement accuracy | ±0.001Hz | |
| Power factor | Measurement range | -1-+1 |
| Measurement accuracy | ±0.005 | |
| Power | Active power accuracy | 0.5% |
| Reactive power accuracy | 1% | |
| Apparent power accuracy | 0.5% | |
| Energy | Active energy accuracy | 0.5% |
| Reactive energy accuracy | 1% | |
| Apparent energy accuracy | 0.5% |
- Record storage
| Data record | |
| Record name | Settable |
| Record start time | Settable |
| Record duration | Selectable |
| Recording interval | Settable |
| Basic data record | Phase voltage Line voltage Current Frequency Power factor Fundamental harmonic power factor Power(Active, Reactive, Apparent) Active Energy (Import energy, Export energy) Reactive energy (Import energy, Export energy) Apparent Energy Voltage harmonics (Total harmonic, odd total harmonic, even total harmonic) Current harmonics (Total harmonic, odd total harmonic, even total harmonic) Phase voltage peak Peak factor of phase voltage Current crest factor Current K factor Voltage unbalance (negative sequence, zero sequence) Current unbalance (negative sequence, zero sequence) Angle (phase voltage angle, phase current angle, angle between voltages, angle between currents, angle between voltages and currents) Max min (Phase voltage, Line voltage, Current, Frequency, Power factor, Fundamental harmonic power factor, Active power, Reactive power, Apparent power) Demand (Current, Active power, Reactive power, Apparent power) Peak Demand (Current, Active power, Reactive power, Apparent power) |
| Voltage harmonic data record | Voltage harmonics (Total harmonic distortion THD, Odd total harmonic TOHD, Even total harmonic TEHD, 1-50th Harmonic percentage and voltage value) |
| Current harmonic data record | Current harmonics (total harmonic distortion THD, Odd total harmonicTOHD, Even total harmonic TEHD, 1-50th Harmonic percentage and current value) |
| Data storage format | CSV |
| Event record [[1]] | |
| Recorded data | Event type Start time Duration Amplitude value |
| Data storage format | CSV |
| Waveform recording | |
| Record name | Settable |
| Record the start time | Settable |
| Record the duration | Settable |
| Sampling rate | Settable |
| Logged data | Phase ABC voltage waveform Phase ABC current waveform |
| Data storage format | CSV |
[[1]] Event recording can only be performed when data recording is enabled.
- Similar Products
$50.00
1 Piece (MOQ)
Sts Smart Prepaid Prepayment Electricity Energy Meter
Zhongcheng Metering Limited