Model NO.:
AV-2000B2
Type:
Anesthesia Ventilator
Used for:
Adult
Display:
High-Definition 10.4" TFT Color LCD Screen
Ventilation Modes:
Ippv, Sippv, Simv, Peep, Manual, Sigh, Imv, Vcv
Tidal Volume:
20-2000 Ml
Rate:
1~120bpm
Simvrate:
2~20bpm
I:E:
4:1~1:8
Pressure Trigger Sensitivity:
-1.0~1.0kpa
Flow Trigger Sensitivity:
1-20L/Min
Peep:
0~2.0kpa
Pressure Range:
3~60CMH2o
Certification:
CE, ISO13485
Source:
Nitrous Oxide
Anesthesia:
Semi Open Suction
Kind:
Surgical Operation
Group:
Adult & Children
Trademark:
SX for ventilator
Transport Package:
Wooden Case
Specification:
CE, ISO9001
Origin:
China, Jiangsu
Product Description
Ventilator with CE
V-2000B
2 Ventilator

AV-2000B2 is a multi-functional Ventilator, it is applicable for children and adults in sickroom,
 ICU or of emergency.

 
Ventilator
Display mode                 High-definition 10.4" TFT color LCD screen display
Ventilation mode               IPPV, SIPPV, SIMV, PEEPMANUALSIGH,
IMV, VCV, PCV
Ventilation parameters            Tidal volume      20~2000 ml
Rate           1~120 bpm
SIMV rate       2~20 bpm
I:E            4:1~1:8
Pressure trigger sensitivity -1.0-2.0kPa
Flow trigger sensitivity  1-20L/min
PEEP           0~2.0Kpa
Pressure range    3~60cmH2O
Pressure support    3~60cmH2O
SIGH           1.5 times the inspiratory time(60-120 adjustable)
Inspiratory platform  0~50% 
Oxygen concentration 21~100%
Pressure limitation   5~60cmH2O
Pressure slope      1~10gear
Flow rate setting    1~10gear
Expiratory trigger pressure -1.0~2.0Kpa
Time control    1~10s
 Parameters for ventilation monitoring     tidal volumeventilation volume, IPPV rate, SIMV rate, total respiratory rateI/Epeak pressure of airway, average pressure, pressure - time waveform, flow rate - time waveform, PEEP, inspiratory trigger pressure, Inspiratory platform (autonomous inspiratory rate, lung compliance, airway resistance, flow -volume loop, pressure-volume loop)
Monitoring of oxygen concentration     48%~100%
Security Alarm System
Oxygen Concentration alarm       upper limit setting range 21%~100%
                               low limit setting range   10%~80%
Airway pressure alarm           upper limit setting range  0.3~6.0 kPa
low limit setting range   0.2~5.0 kPa
Per-minute ventilation volume alarm       upper limit setting range  3.0~30L/min
low limit setting range   1.0~10L/min 
Respiratory rate                 upper limit setting range  50~99bpm
low limit setting range   0~50bpm 
Tidal volume                   upper limit setting range  10~2000ml
low limit setting range   0~1800ml
Sustained high-pressure alarm     it will give alarm when stress have consistently
been higher than 2.5 kPa 
Suffocation alarm                it will give sound and light alarm if there is 
no tidal volume input for 15 seconds
Power alarm
Gas shortage alarm
Intubation off alarm
 Power                          AC 220V±10%     50Hz±1Hz
                              UPS, Storage battery