Swipe or use the arrows to view product images.
Medical Respiratory with CE
| Price | $7300.00 |
|---|---|
| Min Order | 1 Piece |
| Availability | In Stock |
| Shipping From | Jiangsu, China |
| Popularity | 514 people viewed |
Model NO.:
AV-2000B2
Type:
Anesthesia Ventilator
Used for:
Adult
Display:
High-Definition 10.4" TFT Color LCD Screen
Ventilation Modes:
Ippv, Sippv, Simv, Peep, Manual, Sigh, Imv, Vcv
Tidal Volume:
20-2000 Ml
Rate:
1~120bpm
Simvrate:
2~20bpm
I:E:
4:1~1:8
Pressure Trigger Sensitivity:
-1.0~1.0kpa
Flow Trigger Sensitivity:
1-20L/Min
Peep:
0~2.0kpa
Pressure Range:
3~60CMH2o
Certification:
CE, ISO13485
Source:
Nitrous Oxide
Anesthesia:
Semi Open Suction
Kind:
Surgical Operation
Group:
Adult & Children
Trademark:
SX for ventilator
Transport Package:
Wooden Case
Specification:
CE, ISO9001
Origin:
China, Jiangsu
Product Description
Ventilator with CE
V-2000B2 Ventilator
AV-2000B2 is a multi-functional Ventilator, it is applicable for children and adults in sickroom,
ICU or of emergency.
Ventilator
Display mode High-definition 10.4" TFT color LCD screen display
Ventilation mode IPPV, SIPPV, SIMV, PEEP, MANUAL, SIGH,
IMV, VCV, PCV
Ventilation parameters Tidal volume 20~2000 ml
Rate 1~120 bpm
SIMV rate 2~20 bpm
I:E 4:1~1:8
Pressure trigger sensitivity -1.0-2.0kPa
Flow trigger sensitivity 1-20L/min
PEEP 0~2.0Kpa
Pressure range 3~60cmH2O
Pressure support 3~60cmH2O
SIGH 1.5 times the inspiratory time(60-120 adjustable)
Inspiratory platform 0~50%
Oxygen concentration 21~100%
Pressure limitation 5~60cmH2O
Pressure slope 1~10gear
Flow rate setting 1~10gear
Expiratory trigger pressure -1.0~2.0Kpa
Time control 1~10s
Parameters for ventilation monitoring tidal volume, ventilation volume, IPPV rate, SIMV rate, total respiratory rate, I/E, peak pressure of airway, average pressure, pressure - time waveform, flow rate - time waveform, PEEP, inspiratory trigger pressure, Inspiratory platform (autonomous inspiratory rate, lung compliance, airway resistance, flow -volume loop, pressure-volume loop)
Monitoring of oxygen concentration 48%~100%
Security Alarm System
Oxygen Concentration alarm upper limit setting range 21%~100%
low limit setting range 10%~80%
Airway pressure alarm upper limit setting range 0.3~6.0 kPa
low limit setting range 0.2~5.0 kPa
Per-minute ventilation volume alarm upper limit setting range 3.0~30L/min
low limit setting range 1.0~10L/min
Respiratory rate upper limit setting range 50~99bpm
low limit setting range 0~50bpm
Tidal volume upper limit setting range 10~2000ml
low limit setting range 0~1800ml
Sustained high-pressure alarm it will give alarm when stress have consistently
been higher than 2.5 kPa
Suffocation alarm it will give sound and light alarm if there is
no tidal volume input for 15 seconds
Power alarm
Gas shortage alarm
Intubation off alarm
Power AC 220V±10% 50Hz±1Hz
UPS, Storage battery
Mechanical Arms
V-2000B2 Ventilator
AV-2000B2 is a multi-functional Ventilator, it is applicable for children and adults in sickroom,
ICU or of emergency.
Ventilator
Display mode High-definition 10.4" TFT color LCD screen display
Ventilation mode IPPV, SIPPV, SIMV, PEEP, MANUAL, SIGH,
IMV, VCV, PCV
Ventilation parameters Tidal volume 20~2000 ml
Rate 1~120 bpm
SIMV rate 2~20 bpm
I:E 4:1~1:8
Pressure trigger sensitivity -1.0-2.0kPa
Flow trigger sensitivity 1-20L/min
PEEP 0~2.0Kpa
Pressure range 3~60cmH2O
Pressure support 3~60cmH2O
SIGH 1.5 times the inspiratory time(60-120 adjustable)
Inspiratory platform 0~50%
Oxygen concentration 21~100%
Pressure limitation 5~60cmH2O
Pressure slope 1~10gear
Flow rate setting 1~10gear
Expiratory trigger pressure -1.0~2.0Kpa
Time control 1~10s
Parameters for ventilation monitoring tidal volume, ventilation volume, IPPV rate, SIMV rate, total respiratory rate, I/E, peak pressure of airway, average pressure, pressure - time waveform, flow rate - time waveform, PEEP, inspiratory trigger pressure, Inspiratory platform (autonomous inspiratory rate, lung compliance, airway resistance, flow -volume loop, pressure-volume loop)
Monitoring of oxygen concentration 48%~100%
Security Alarm System
Oxygen Concentration alarm upper limit setting range 21%~100%
low limit setting range 10%~80%
Airway pressure alarm upper limit setting range 0.3~6.0 kPa
low limit setting range 0.2~5.0 kPa
Per-minute ventilation volume alarm upper limit setting range 3.0~30L/min
low limit setting range 1.0~10L/min
Respiratory rate upper limit setting range 50~99bpm
low limit setting range 0~50bpm
Tidal volume upper limit setting range 10~2000ml
low limit setting range 0~1800ml
Sustained high-pressure alarm it will give alarm when stress have consistently
been higher than 2.5 kPa
Suffocation alarm it will give sound and light alarm if there is
no tidal volume input for 15 seconds
Power alarm
Gas shortage alarm
Intubation off alarm
Power AC 220V±10% 50Hz±1Hz
UPS, Storage battery
Mechanical Arms
- Similar Products