Menu
Global B2B sourcing platform
Verified suppliers and manufacturers

Medical Treatment Equipment Dialysis Therapy Room Clinical Dialyzer Reprocessing Machine

Price $7500.00
Min Order 1 Piece
Availability In Stock
Shipping From Shanghai, China
Popularity 406 people viewed
Model NO.:
W-F168-B
Customized:
Non-Customized
Certification:
CE, ISO13485
Type of Body Fluid-Processing Device:
Human Blood Processor
Model:
Dialyzer Reprocessing Machine W-F168-B
Water Input Pressure:
0.15~0.35MPa, (20p.S.I~50p.S.I)
Water Input Temperature:
10ºC~40ºC
Minimum Water Inlet Flow:
1.5L/Min
Reprocessing Time:
About 12 Minutes Per Cycle
Work Environment Temperature:
5ºC~40ºC
Storage Temperature Should Be Between:
5ºC~40ºC at Relative Humidity<=80%;
Warrnty:
12 Months
in Put Power:
150W
Trademark:
Mermaid
Transport Package:
Carton
Specification:
CE ISO
Origin:
China
Product Description
Medical Treatment Equipment Dialysis Therapy Room Clinical Dialyzer reprocessing machine W-F168-B

Dialyzer reprocessing machine is the main device for hospital to sterilize, clean, test and affuse reusable dialyzer used in hemodialysis treatment. And can just been used in hospital only.

Advantages:
1. Reduce the burden on medical staff: Dialysis machine can automate the cleaning, testing, and disinfection of dialyzers, thereby reducing the workload of medical staff and freeing them from tedious manual reuse
2. Improve the efficiency of dialyzers: Through the reuse machine, dialyzers can be reused 5-20 times, significantly reducing the cost of dialysis consumables and saving medical costs
3. Improve biocompatibility: The reuse machine reduces discomfort and side effects for patients during dialysis by improving the biocompatibility of the dialysis membrane, thereby enhancing patient comfort
4. Environmental benefits: Due to the fact that dialyzers are non degradable materials, large-scale disposal can cause a burden on the environment. Reusing dialyzers through reuse machines can help reduce environmental pollution
5.Prevention of allergic reactions: Disinfection with ethylene oxide can effectively prevent the syndrome of first-time use of dialyzers and allergic reactions, reducing the risk of allergies caused by new dialyzers in patients

Models:
1. W-F168-A: Can only clean one dialyzer automatically.
2. W-F168-B: Can clean two dialyzers separately at the same time within around 12 minutes.

Description:
ModelW-F168-B(Double work station)
Water input pressure: 0.15~0.35Mpa, (20P.S.I~50P.S.I)
Water input temperature: 10ºC~40ºC
Minimum water inlet flow: 1.5L/min
Reprocessing time: about 12 minutes per cycle
Work environment temperature 5ºC~40ºC
Storage temperature should be between5ºC~40ºC at relative humidity<=80%;
In put power150W
 