Swipe or use the arrows to view product images.
NiCr/Ni Al/Si chromel alumel/Nickel chrome-Nickel silicon/ type K Thermocouple bar alloy Wire forelectric insluated cable KP KN (Type K/N/J/T/E) / copper wire
| Price | Negotiable |
|---|---|
| Min Order | 100 kg |
| Availability | In Stock |
| Shipping From | Shandong, China |
| Popularity | 509 people viewed |
Model NO.:
K
Type:
Bare
Conductor Type:
Solid
Application:
Heating
Conductor Material:
Ni Cr Si Al
Sheath Material:
No
Insulation Material:
Bare
Material Shape:
Round Wire
Range of Application:
Heating, Temperature Measurement
Certification:
ISO9001, RoHS
Brand:
Liqun
Model No.:
K
Diameter:
0.2-3.2mm
Positive Pole:
Nickel Chromel
Negative Pole:
Nickel Silicon/Nickel Aluminum
OEM/ODM:
Yes
MOQ:
100kg
Temperature Range:
-270~1372
Sample:
Available
Surface:
Bright/ oxidized thermocouple wire
Trademark:
Liqun
Transport Package:
Plywood Cases
Specification:
3.2/2.5/2.0/1.29/0.813/0.5/0.3/0.2mm
Origin:
China
HS Code:
75052200
Product Description
Manufacturer Thermocouple Bare Alloy Wire (Type K/N/E/J/T)
Type K is the most commonly used thermocouple for measuring high temperatures, providing the widest operating temperature range from - 200 ° to + 1260 °C.Type K has a better resistance to oxidation than other types of thermocouple (except type N) and is particularly recommended for oxidizing or inert atmospheres.It should not be used without protection in sulphurous atmospheres, in reducing atmospheres or a long time in a vacuum.Must be protected from sulfurous and marginally oxidizing atmospheres. Reliable and accurate at high temperatures.
Type N thermocouple has been developed which provides much longer life, longer exposure to high temperature and better reliability of EMF drift and short term EMF changes.
Type E thermocouple has the highest EMF output per degree of all the referenced thermocouples.
Type J Thermocouple is frequently used for its low cost and high EMF It can be used in oxidizing conditions up to 760°C. For higher temperatures, it is recommended to use large wire diameters.Type J thermocouple is suitable for oxidizing, reducing inert atmosphere or vacuum.
Type T thermocouple is suitable for oxidizing, reducing inert atmosphere or vacuum.
Type N thermocouple has been developed which provides much longer life, longer exposure to high temperature and better reliability of EMF drift and short term EMF changes.
Type E thermocouple has the highest EMF output per degree of all the referenced thermocouples.
Type J Thermocouple is frequently used for its low cost and high EMF It can be used in oxidizing conditions up to 760°C. For higher temperatures, it is recommended to use large wire diameters.Type J thermocouple is suitable for oxidizing, reducing inert atmosphere or vacuum.
Type T thermocouple is suitable for oxidizing, reducing inert atmosphere or vacuum.
1.Chemical composition and mechanical properties
| Product | Chemical Composition/% | Density (g/cm3) | Melting point (ºC) | Resistivity (μΩ.cm) | Tensile Strength (Mpa) | |||||||
| Ni | Cr | Si | Al | Mg | Fe | Cu | ||||||
| KP(+) Nickel Chrome | 90 | 10 | - | - | - | - | - | 8.7 | 1427 | 70 | ≥490 | |
| KN(-) Nickel Silicon | 97 | - | 3 | - | - | - | - | 8.6 | 1399 | 29 | ≥390 | |
| KN(-) Nickel Aluminum | 96 | - | 1 | 3 | - | - | - | 8.6 | 1399 | 29 | ≥390 | |
| NP(+) Nickel Chrome Silicon | Blance | 13.7-14.7 | 1.2-1.6 | - | <0.01<> | - | - | 8.7 | 1427 | 70 | ≥490 | |
| NN(-) Nickel Silicon Magnesium | Blance | <0.02<> | 4.2-4.6 | - | 0.5-1.5 | - | - | 8.6 | 1399 | 29 | ≥390 | |
| EP(+) Nickel Chrome | 90 | 10 | - | - | - | - | - | 8.5 | 1427 | 70.6 | ≥490 | |
| EN(-) Copper Nickel | 45 | - | - | - | - | - | 55 | 8.8 | 1220 | 49 | ≥390 | |
| JP(+) Pure Iron | - | - | - | - | - | 100 | - | 7.8 | 1402 | 12 | ≥240 | |
| JN(-) Copper Nickel | 45 | - | - | - | - | - | 55 | 8.8 | 1220 | 49 | ≥390 | |
| TP(+) Copper Wire | - | - | - | - | - | - | 100 | 8.9 | 1084 | 1.71 | ≥196 | |
| TN(-) Copper Nickel | 45 | - | - | - | - | - | 55 | 8.8 | 1220 | 49 | ≥390 | |
<0.01<><0.01<><0.02<><0.02<>
2.Maximum operating temperatures
| Product | Alloy wire Dia/mm | The long-term operating temperatures/°C | The short-term operating temperatures/°C |
| KP/KN | 0.3 | 700 | 800 |
| 0.5 | 800 | 900 | |
| 0.8,1.0 | 900 | 1000 | |
| 1.2,1.6 | 1000 | 1100 | |
| 2.0,2.5 | 1100 | 1200 | |
| 3.2 | 1200 | 1300 | |
| NP/NN | 0.3 | 700 | 800 |
| 0.5 | 800 | 900 | |
| 0.8,1.0 | 900 | 1000 | |
| 1.2,1.6 | 1000 | 1100 | |
| 2.0,2.5 | 1100 | 1200 | |
| 3.2 | 1200 | 1300 | |
| EP/EN | 0.3,0.5 | 350 | 450 |
| 0.8,1.0,1.2 | 450 | 550 | |
| 1.6,2.0 | 550 | 650 | |
| 2.5 | 650 | 750 | |
| 3.2 | 750 | 900 | |
| JP/JN | 0.3,0.5 | 300 | 400 |
| 0.8,1.0,1.2 | 400 | 500 | |
| 1.6,2.0 | 500 | 600 | |
| 2.5,3.2 | 600 | 750 | |
| TP/TN | 0.2,0.3 | 150 | 200 |
| 0.5,0.8 | 200 | 250 |
3.EMF reference table (μV)
| Product | Operating temperatures/°C | Nominal value of thermoelectric EMF | Level I | |
| Tolerance | Range of EMF | |||
| KP/KN | 100 | 4 096 | ±46 | 4 050-4 142 |
| 200 | 8 138 | ±44 | 8 094-8 182 | |
| 300 | 12 209 | ±50 | 12 159-12 259 | |
| 400 | 16 397 | ±68 | 16 329-16 465 | |
| 500 | 20 644 | ±85 | 20 559-20 729 | |
| 600 | 24 905 | ±102 | 24 803-25 007 | |
| 700 | 29 129 | ±117 | 29 012-29 246 | |
| 800 | 33 275 | ±131 | 33 144-33 406 | |
| 900 | 37 326 | ±144 | 37 182-37 470 | |
| 1000 | 41 276 | ±156 | 41 120-41 432 | |
| 1100 | 45 119 | ±167 | 44 952-45 286 | |
| 1200 | 48 838 | - | - | |
| 1300 | 52 410 | - | - | |
| Product | Operating temperatures/°C | Nominal value of thermoelectric EMF | Level I | |
| Tolerance | Range of EMF | |||
| NP/NN | 100 | 2774 | ±44 | 2730-2818 |
| 200 | 5913 | ±49 | 5864-5962 | |
| 300 | 9341 | ±53 | 9288-9394 | |
| 400 | 12974 | ±59 | 12915-13033 | |
| 500 | 16748 | ±76 | 16672-16824 | |
| 600 | 20613 | ±94 | 20519-20707 | |
| 700 | 24527 | ±110 | 24417-24637 | |
| 800 | 28455 | ±126 | 28329-28581 | |
| 900 | 32371 | ±140 | 32231-32511 | |
| 1000 | 36256 | ±154 | 36102-36410 | |
| 1100 | 40087 | ±167 | 39920-40254 | |
| 1200 | 43846 | - | - | |
| 1300 | 47477 | - | - | |
| Product | Operating temperatures/°C | Nominal value of thermoelectric EMF | Level I | |
| Tolerance | Range of EMF | |||
| EP/EN | 100 | 6 319 | ±68 | 6 251-6 387 |
| 200 | 13 421 | ±74 | 13 347-13 495 | |
| 300 | 21 036 | ±93 | 20 943-21 129 | |
| 400 | 28 946 | ±128 | 28 818-29 074 | |
| 500 | 37 005 | ±162 | 36 843-37 167 | |
| 600 | 45 093 | ±194 | 44 899-45 287 | |
| 700 | 53 112 | ±223 | 52 889-53 335 | |
| 800 | 61 017 | ±251 | 60 766-61 268 | |
| 900 | 66 787 | - | - | |
| Product | Operating temperatures/°C | Nominal value of thermoelectric EMF | Level I | |
| Tolerance | Range of EMF | |||
| JP/JN | 100 | 5 269 | ±82 | 5 187-5 351 |
| 200 | 10 779 | ±83 | 10 696-10 862 | |
| 300 | 16 327 | ±83 | 16 244-16 410 | |
| 400 | 21 848 | ±88 | 21 760-21 936 | |
| 500 | 27 393 | ±112 | 27 281-27 505 | |
| 600 | 33 102 | ±140 | 32 962-33 242 | |
| 700 | 39 132 | ±174 | 38 958-39 306 | |
| 750 | 42 281 | ±192 | 42 089-42 437 | |
| 760 | 42 919 | ±194 | 42 725-43 113 | |
| Product | Operating temperatures/°C | Nominal value of thermoelectric EMF | Level I | |
| Tolerance | Range of EMF | |||
| TP/TN | 100 | 4 279 | ±24 | 4 255-4 303 |
| 150 | 6 704 | ±30 | 6 674-6 734 | |
| 200 | 9 288 | ±43 | 9 245-9 331 | |
| 250 | 12 013 | ±56 | 11 957-12 069 | |
| 300 | 14 862 | ±70 | 14 792-14 932 | |
| 350 | 17 818 | ±74 | 17 744-17 892 | |
Our production as per norm GB/T 2614-2010,ASTME230,IEC6584.For further information or special request, please contact us.
Q1.What is the nature of the company?
A: We are a production enterprise, our company has its own factory.
Q2. What is the MOQ of an order of your company?
A: Our company's MOQ is 100 kg for each type of product.
Q3.Can I get a sample before mass production ?
A: Sample is free,the shipping cost of the sample is paid by the customer .
Q4.How long is the mass production cycle of product?
We will end the production within 15-20 days after receiving the deposit.
Q5.What payment method does your company support?
A: We can accept T/T, L/C ,you can choose the one which the most convenient or most effective for you .
A: We are a production enterprise, our company has its own factory.
Q2. What is the MOQ of an order of your company?
A: Our company's MOQ is 100 kg for each type of product.
Q3.Can I get a sample before mass production ?
A: Sample is free,the shipping cost of the sample is paid by the customer .
Q4.How long is the mass production cycle of product?
We will end the production within 15-20 days after receiving the deposit.
Q5.What payment method does your company support?
A: We can accept T/T, L/C ,you can choose the one which the most convenient or most effective for you .
- Similar Products
$10.00
100 Meters (MOQ)
Kvv/Kvvr/Kvvp/Kvvrp Factory Hot Product Aluminum Alloy Electric Cable
Kunyi Cable Co., Ltd.
$8.80
1000 Pieces (MOQ)
Abrasion Resistant Tpee Spring Cable Wire Coil Trailer Cable