Negotiable
1 Piece (MOQ)
Line Interactive UPS 2kVA with Battery Backup Power System
APLUS POWER CORP.
Swipe or use the arrows to view product images.
Nobreak UPS Uninterruptible Power Supply 10kVA 15kVA 20kVA UPS Single Phase UPS
| Price | $548.42 |
|---|---|
| Min Order | 1 Piece |
| Availability | In Stock |
| Shipping From | Zhejiang, China |
| Popularity | 571 people viewed |
Model NO.:
XG6-20kVA
Phase:
Single Phase
Type:
On-line
Protection:
Overvoltage
Application:
Industry
Classification:
Lighting/Power
Standby Time:
Standard Machine
Standby UPS:
Sine Wave Output UPS
Output Capacity:
Large Type
Equipment Mode:
Centralized Model
Brand:
Kemapower
Size:
710*440*860
Product Name:
High Frequency Online UPS
Output Power Factor:
0.8 or 0.9PF
Communication:
RS232 or USB
Trademark:
KEMAPOWER
Transport Package:
Safety Packing
Specification:
ISO / CE / UL
Origin:
China
HS Code:
8504402000
Product Description
High Frequency Online UPS
XG6-20K(S) 6-20KVA, 4.8-16KW
XG6-20K(S) 6-20KVA, 4.8-16KW
Key Features
- LCD High frequency sine wave online UPS 6K/ 10K/ 15K/ 20KVA
- DSP digital control double conversion technology, Zero transfer time
- Single phase, output Power Factor 0.8/0.9, adjustable VAC and HZ by panel
- Wide input voltage and frequency range, support Generator
- Advanced Input PFC technology, 0.99
- Self-testing, and battery management function
- Automatic battery charging while UPS off mode
- Lightning, surge, Short circuit and overload protection, Alarm or Silence settable
- RS232 or USB communication with monitoring software
- SNMP, EPO, MBS are optional
| Item | Model | XG6K | XG6KS | XG10K | XG10KS | XG15K | XG15KS | XG20K | XG20KS |
| Capacity | VA / Watts | 6KVA / 4.8KW | 6KVA / 4.8KW | 10KVA / 8KW | 10KVA / 8KW | 15KVA/12KW | 15KVA/12KW | 20KVA/16KW | 20KVA/16KW |
| Input | Normal Voltage | 220VAC | |||||||
| Turn On Voltage Range | (120±5~274±5)VAC | ||||||||
| Frequency Range | 40~60Hz+-0.2(adjustable) | ||||||||
| Input Power Factor | >0.99(220VAC,full R load) | ||||||||
| Generator | Support generator input(Generator rating≥2*UPS rating ) | ||||||||
| Line Low Loss/ComeBack | 220VAC:(120±5)VAC/(140±5)VAC when Load≤50% | ||||||||
| 220VAC:(150±5)VAC/(165±5)VAC when 50%< Load≤80% | |||||||||
| 220VAC:(160±5)VAC/(175±5)VAC when 80%< Load | |||||||||
| Output | Voltage Range | 200VAC/208VAC/220VAC/230VAC/240VAC, need to confirm before order(Could be adjusted by software,10% derating for 208VAC/200VAC) | |||||||
| Frequency Range | 40~60Hz+-0.2(adjustable) | ||||||||
| Wave Form | Pure Sine Wave | ||||||||
| Transfer Time | 0 ms, Between Line mode and Bat mode | ||||||||
| Transfer time: 4ms (typical 2.5ms), line Mode and bypass mode | |||||||||
| Voltage Distortion | ≤6%,Full RCD load | ||||||||
| Voltage Distortion | ≤2%,Full R load | ||||||||
| Overload Capacity | load≤105%±5%, warning only, 105%+-5%<Load≤125% +-5% ,1min ; 125%±5%<load≤135%±5% , 30S ; Load>135%±5%, 100MS | ||||||||
| Load Peak Ratio | 3:1(max) | ||||||||
| Battery | Battery Type | Maintenance free valve regulated lead acid (VRLA) battery | |||||||
| Battery Voltage | 192VDC or 240VDC | ||||||||
| Battery Capacity | 16*7A or 20*7AH, 9AH Option | External | 16*7A or 20*7AH, 9AH Option | External | 20*9AH, 7Ah option | External | 20*9AH, 7Ah option | External | |
| Recharge Time | 7 hours to 90% capacity | Depended on battery capacity | 7 hours to 90% capacity | Depended on battery capacity | 7 hours to 90% capacity | Depended on battery capacity | 7 hours to 90% capacity | Depended on battery capacity | |
| Charge Current | 1 or 2.5A | Normal 5Amp. Max 7Amp | 1 or 2.5A | Normal 5Amp. Max 7Amp | 1 or 2.5A | Normal 5Amp. Max 7Amp | 1 or 2.5A | Normal 5Amp. Max 7Amp | |
| Display | LED Display | Line , Inverter , Bypass, battery | |||||||
| LCD Display | LCD For input output HZ/VAC, Bat %/VDC, Load % and VA/Watts,Temp. Fault Code ,LED for line,bat, Inverter, Bypss,Fault | ||||||||
| Audible Alarm | Battery Mode | Beeping every 4 min (re-settable) | |||||||
| Overload | Beeping every 1 min | ||||||||
| Fault | Beeping Continuously | ||||||||
| Bettery Low/Charger Fault | Beeping every 1 min | ||||||||
| Bypass Mode | Beeping every 2 min | ||||||||
| L/N Inverse | Beeping every 2 min | ||||||||
| Communications | RS-232/USB Interface | RS232 or USB, With monitoring software | |||||||
| Working Environment | Surge Protection | RJ-45 I/O port available for network or Fax/Modem | |||||||
| Working Temperature | 0ºC~40ºC | ||||||||
| Humidity | 0-95% non-condensing | ||||||||
| Product size | WxDxH (mm) | 260*533*560 | 190*425*328 | 260*533*560 | 260*533*501 | 560*260*717 | 533*260*501 | 560*260*717 | 533*260*501 |
| Product Weight | Kg | 55/63(7AH) | 12.2 | 62/70(9AH) | 21 | 83(9AH) | 32 | 84(9AH) | 33 |
| PCS/CTN | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | |
| CTN size | WxDxH (mm) | 360*640*760 | 295*565*445 | 360*640*760 | 395*690*650 | 705*430*960 | 640*360*760 | 705*430*960 | 640*360*760 |
| CTN Weight(G/W) | Kg | 65/73(7AH) | 14.3 | 72/80(9AH) | 24 | 92(9AH) | 35 | 96(9AH) | 36 |
| REMARK | XG*K --- Standard Type Internal battery, XG*KS---- Long backup Type,External battery | ||||||||
Product Display
10KS/15KS/ 20KS - 260*533*501 mm
15K/ 20K - 560*260*717 mm
15K/ 20K - 560*260*717 mm
- Similar Products
$695.00
5 Pieces (MOQ)
APC 2200va Smart UPS Powe Supply Sua2200ich
Shenzhen E-Flourish Technology Co., Ltd.
Negotiable
200 Pieces (MOQ)
Different Size Online UPS HP9116c 1k 2k 3k
Shenzhen SORO Electronics Co., Ltd.
$3180.00
1 Piece (MOQ)
30kVA/24kw 3 Phases 4 Wires Sine Wave Line Interactive UPS
Shenzhen Bosin Power Co., Ltd.