Menu
Global B2B sourcing platform
Verified suppliers and manufacturers

Outdoor High Voltage Isolation Vacuum Load Switch Fuse Switch

Price $2000.00
Min Order 1 Piece
Availability In Stock
Shipping From Zhejiang, China
Popularity 262 people viewed
Model NO.:
FZW32-12
Breaking Capacity:
High Voltage Circuit Breakers
Operation:
Electric Type
Speed:
Normal Type Circuit Breaker
Arc-extinguishing Medium:
Vacuum
Installation:
Fixed
Structure:
ACB
Poles Number:
1
Type:
Circuit Breaker
Function:
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB
Certification:
ISO9001-2000, CCC
Rated Voltage:
12
Rated Frequency:
50
Rated Current:
630
Mechanical Endurance:
10000
Trademark:
BDN
Transport Package:
Carton
Specification:
medium
Origin:
China
HS Code:
85353090
Product Description

General


Each technical performance index outdoor high voltage isolating vacuum load switch completely reachedGB3804 and IEC standards. It is suitable for power supply network with rated voltage of 12kV, rated current of 630A and 3-phase AC 50Hz and used for closing and opening load current.

Service environment

 
  • Ambient temperature:+40ºC~-30ºC;

  • Altitude above sea level not exceed 2000m;

  • Relative humidity : Daily average value not exceed 95%,Monthly average value not exceed 90%;

  • No frequent extreme vibration.

Key Feature

 
  • Using vacuum arc extinguishing chamber, no explosion danger, no maintenance.

  • The isolation knife is connected with the three-phase vacuum interrupter, and the isolation fracture is visible when the brake is opened.

  • All parts of the body are made of stainless steel, and the bottom frame is made of carbon steel with hot dip galvanized plus ultraviolet protection coating to ensure the normal operation of the body in outdoor environment.

  • The installation mode is mainly single-pole operation, which can be operated manually, electrically or remotely.

  • Widely used in rural power grid, urban network, railway and other configuration line transformation.

  • Large breaking capacity, safe and reliable, long electrical life, frequent operation.

 

Product Parameters

 

NameUnitData
Rated voltagekV12
Rated frequencyHz50
Rated currentA630
Rated active load breaking currentA630
Rated loop breaking currentA630
5%Rated active load breaking currentA31.5
Rated cable charging breaking currentA10
Rated no load transformer breaking capacitykVA1600
Rated breaking capacitor bank currentA100
P.t withstand voltage for 1min: Across vacuum open contacts.
between phases, phase to earth /across open contacts
kV42/48
Lightning impulse withstand voltage : between phases,phase to earth /across open contactskV75/85
Rated short time withstand currentkA20
Rated short circuit durations4
Rated peak withstand currentkA50
Rated short circuit making currentkA50
Mechanical enduranceTime10000
Allowable wear thickNess of contact of vacuum interruptermm0.5
Operating torqueNm200

Certifications

 

Workshop

 

Packaging & Shipping

 

  • Similar Products