Menu
Global B2B sourcing platform
Verified suppliers and manufacturers

Outdoor Vacuum Circuit Breaker Switch Spring Energy Storage Operating Mechanism 12kv

Price $2000.00
Min Order 1 Piece
Availability In Stock
Shipping From Zhejiang, China
Popularity 384 people viewed
Model NO.:
ZW8-12
Breaking Capacity:
High Voltage Circuit Breakers
Operation:
Electric Type
Speed:
High-Speed Circuit Breaker
Arc-extinguishing Medium:
Vacuum
Installation:
Fixed
Structure:
ACB
Poles Number:
1
Type:
Circuit Breaker
Function:
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB
Certification:
ISO9001-2000, CCC
Brand:
Bdn
Place of Orignal:
Zhe Jiang
Phase Number:
3
Mechanical Life:
10000
Rated Voltage:
10
Rated Current:
630
Insulation:
Casting Insulation
Trademark:
BDN
Transport Package:
Wooden Case
Specification:
medium
Origin:
China
HS Code:
85353010
Product Description
 

General

Outdoor AC vacuum circuit breaker is used to make and break load current, overload current and short-circuit current in12kV,50/60Hz power system. Its applicable for substations, industry and mining, urban and rural electricity power networks, especially applicable in occasions with frequent operation and automatic power distribution network.

Service environment

  • Altitude:≤2000mm;

  • Ambient air temperature:-40C-+45ºC;

  • Wind speed: 34m/s;

  • Earthquake intensity:8degree;

  • Relative humidity: monthly average 90%, daily average 95%;

  • Ice thickNess: 10mm;

  • Pollution degree: IV;

  • There will be have dew under the condition of high temperature low down hastily.

 

Product Parameters

NameUnitData
16kA20kA25kA
Rated voltagekV10
Max. operation voltagekV12
Rated currentA630/1250
Rated short-circuit breaking currentkA162025
Rated short-circuit making currentkA405063
Rated peak withstand currentkA405063
Rated short-time withstand currentkA162025
Rated Insulate level1min P.F withstand voltagekV42/48
Lightning impulse withstand voltage(peak)kV75
Rated operating sequence O-0.3s-CO-180s-CO
Mechanical lifetimes10000
Rated short-circuit breaking current breaking timestimes30
Rated Operating Setup Closing VoltageVAC220 DC220,100
Rated Operating Setup Opening VoltageVAC220 DC220,100
Contact Strokemm11±1
Contact Over travel (Contact Spring Constringent Length)mm3
Out Of Simultaneity Of Contact Closing And Openingms≤2
Contact Closing Bounce Timems≤2
Average opening Speedm/s1.0±0.2
Average Closing Speedm/s0.7±0.15
Opening Time The Highest Operating Voltages0.015-0.05
The Lowest Operating Voltages0.03-0.06
Contact Closing Times0.025-0.05
Current by Phase Circuit ResistanceμΩ≤120(≤200)
Contact erosion limitmm3

 