Swipe or use the arrows to view product images.
Pcy-III- 1400 Horizontal Coefficient of Thermal Expansion Dilatometer
| Price | Negotiable |
|---|---|
| Min Order | 1 Set |
| Availability | In Stock |
| Shipping From | Hunan, China |
| Popularity | 395 people viewed |
Model NO.:
PCY-III-1400
After-sales Service:
Online Service
Warranty:
1 Year
Voltage:
220V
Temperature Scope:
Rt-1400
Power:
3kw
Trademark:
Hunan Zhenhua
Transport Package:
Export Plywood Case
Specification:
0.3CBM
Origin:
China
HS Code:
9031809090
Product Description
PCY-III- 1400 Horizontal coefficient of thermal expansion dilatometer
The instrument measures the change of sample size as a function of temperature or time under a certain temperature program and the load force is close to zero. It is widely used in inorganic ceramics, metal materials, plastic polymers, building materials, coating materials, refractory materials, composite materials and other fields. Industrial, scientific, research and educational Dilatometers for the measurement of thermal expansion, percent of expansion, alpha ( CTE - Coefficient of Thermal Expansion). The products comply with ISO 10545, ASTM E 831, ASTM D 696, ASTM D 3386, DIN 51045 and other relevant international standards.
Technical specifications:
The instrument measures the change of sample size as a function of temperature or time under a certain temperature program and the load force is close to zero. It is widely used in inorganic ceramics, metal materials, plastic polymers, building materials, coating materials, refractory materials, composite materials and other fields. Industrial, scientific, research and educational Dilatometers for the measurement of thermal expansion, percent of expansion, alpha ( CTE - Coefficient of Thermal Expansion). The products comply with ISO 10545, ASTM E 831, ASTM D 696, ASTM D 3386, DIN 51045 and other relevant international standards.
Technical specifications:
| 1. | Model | PCY-III-1400 |
| 2. | Furnace temperature | RT ~ 1400ºC |
| 3. | Temperature Accuracy | ±1°C, record error ≤± 0.1% |
| 4. | Sample diameter | 6~10mm round or square |
| 5. | Sample length | 50mm(max) |
| 6. | LVDT displacement range | ± 5 mm ± 0.1%, |
| 7. | Heating element | SiC heating element up to 1400ºC |
| 8. | Sample holder | AL2O3 |
| 9. | Dilatometer orientation | Horizontal |
| 10. | Displacement resolution | 0.1μm |
| 11 | Heating rate | 1 ~ 30 oC /minute, Accuracy: ±0.1 oC |
| 12 | Temperature control | Experimental process controls parameters, including PID parameters and the way of communication. |
| 13 | Data Acquisition | Trough onboard computer complete instrument control capabilities and graphical run time experimental monitor , report generation functions, and print tabular data, curve. |
| 14 | Operating Environment: | WINDOWS (10/7/xp) operating system |
| 15 | Power supply | 220V, 50/60HZ |
| 16 | List of accessories | Testing software (English) 1, AL2O3 sample holder 1, AL2O3 standard sample 1, *Computer 1set |
- Similar Products
$18000.00
1 Piece (MOQ)
Ds3 Multi-Channel Acoustic Emission Testing Equipment
Beijing Samyon Instruments Co., Ltd.
$1200.00
1 Piece (MOQ)
Transformer Turns Ratio Test Meter Equipment
Wuhan Goldhome Hipot Electrical Co., Ltd.
Negotiable
1 Piece (MOQ)
HVHIPOT Customized GDTF-4500kVA/750kV AC Resonant test Divice
HV Hipot Electric Co., Ltd.