Model NO.:
HXGN15-12
Certification:
CCC, ISO9001
Voltage Level:
Low Voltage
Installation:
Fixed
Structure:
Floorstanding
Current:
AC
Rated Voltage:
12
Rated Frequency:
50
Fuse Breaking Current:
31.5,40
Mechanical Life:
2000
Trademark:
BDN
Transport Package:
Woodencase
Specification:
Big
Origin:
China
HS Code:
85372000
Product Description

General

All technical performance indicators meet IEC62271-200:2011 and GB3906 standards. This product has the characteristics of small size, light weight, beautiful appearance, easy operation, long life, high parameters, no pollution, less maintenance and so on. HXGN15-12(SF6) type unit-type AC metal closed ring switchgear, suitable for AC 50Hz, 12kV power network, as the acceptance and distribution of electric energy.
 

Service environment

  • Ambient temperature: upper limit +40ºC, lower limit -25ºC;

  • Altitude: No more than 2000m above sea level;

  • Relative temperature: the daily average is not more than 95%; The monthly average is not more than 90%;

  • Surrounding environment: The surrounding air is not exposed to corrosive gases or flammable gases, water vapor, etc

  • Show pollution.

  • No frequent violent vibration.

Key Feature

 
  • The busbar room is located at the top of the cabinet and is connected to the adjacent switchgear

  • Independent load switch with SF6 gas inside

  • 75% of the space is used for cable connections, fuses, ground switches and CT and PT installations

Product Parameters

NameUnitData
Rated voltage kV12
Rated frequencyHz50
Rated current of main bus/Maximum rated current of fuseA630/125
Rated short-time withstand current of main circuit and ground circuitkA/S20/3
Rated peak withstand current of main loop and ground loopkA50
Rated short-circuit closing current of main circuit and ground circuitkA50
Number of times the load switch is broken at full capacityTimes100
Fuse breaking currentkA31.5,40
Rated closed-loop breaking currentA630
Rated transfer currentA1600
Mechanical lifeTimes2000
1min power frequency withstand voltage (peak)to phase,to earth/between open contactskV42/48
Lightning impulse withstand voltage (peak))phase to phase,to earth/between open contactskV75/85
Secondary circuit 1min power frequency voltagekV2
Class of protection IP3X