Self Actuated Temperature Regulator (GAZZWP)
| Price | $1.00 |
|---|---|
| Min Order | 1 Piece |
| Availability | In Stock |
| Shipping From | Zhejiang, China |
| Popularity | 373 people viewed |
Self Actuated Temperature Regulator (GAZZWP)
Product Description:
Technical Specification
Design Reference | GB/T17213/IEC 60534 GB/T4213 |
Design Standard | GB/T17213/IEC 60534 GB/T4213 |
Face to Face Length | GB/T17213.3-2005/IEC 60534-1:2000 |
Flange Dimension | GB 9113.1-2000 |
Test & Inspection | GB/T17213.4-2005/IEC 60534-4:1999 |
Self-Actuated Temperature Control Valve (GAZZWP)
Materials of Major Parts
No | Parts Name | Material (ASTM) |
1 | Body | A216 WCB |
2 | Seat | A182-F304 |
3 | Stem | A182-F304 |
4 | Spring | A182-F304 |
5 | Nut | A182-F304 |
6 | Packing | PTFE |
7 | Valve Bonnet | A216 WCB |
8 | Actuator (Sensor) | Discreteness |
Note: Major Parts of the valve Series and materials of sealing surface differs according to different working condition and customer's special requirements.
Self-Actuated Temperature Control Valve (GAZZWP)
Parameter table of valve
DN (mm) | 20 | 25 | 32 | 40 | 50 | 65 | 80 | 100 | 125 | 150 | 200 |
PN(Mpa) | 1.6MPa, 2.5Mpa, 4.0Mpa | ||||||||||
Kv | 7 | 11 | 2 | 30 | 48 | 75 | 120 | 190 | 300 | 480 | 760 |
Max Pressure Differential Pa (Mpa) | 1.6MPa | 1.5Mpa | 0.5Mpa | ||||||||
TemperatureRange(ºC) | -20~50, 20~90, 40~100, 50~120, 60~130, 110~180, 180~250 | ||||||||||
Adjust Precision | ±5% | ||||||||||
Allowable Overload (c) | +50 | ||||||||||
Ambient Temperature (ºC) | -40~80 | ||||||||||
Seat Leakage | GB/T17213.4-2005/IEC 60534-4:1999 | ||||||||||
Parameter table of Actuator
Model | T06 | T17 |
TemperatureRange(ºC) | -20~50, 20~90, 40~100, 50~120, 60~130 | |
SpecialTemperature Range(ºC) | 110~180, 180~250 | |
Allowable Overload (c) | =50 | |
Time Constant (s) | 120 | 20 |
Material of Temperature Sensor | Nickel Copper Alloy | |
Capillary Length (m) | 5, 10, 15 | |
Model | Size (mm) | Weight (Kg) | |||
H | H1 | R | d | ||
T06 | 380 | 280 | 1" | 24 | 3.0 |
T17 | 500 | 280 | 1" | 30 | 3.5 |
- Temperature Regulating Valve is generally applied in the conditions with slow change of temperature other than conditions with intense change of temperature or frequent change of parameters.
- The temperature sensor of T06 executive unit will not directly contact the medium and thus it is convenient for maintenance but with slow response speed, appropriate for controlling liquid media. While the temperature sensor of T17 executive unit will directly contact the medium with a large area for temperature sensing and fast response speed, but inconvenient for maintenance. It's appropriate for controlling gas temperature, and sometimes for controlling liquid temperature.
- Similar Products