$108.00
10 Pieces (MOQ)
High Accuracys-Type Load Cell with CE Certification Approved
Huzhou Zhihe Technology Co., Ltd.
Swipe or use the arrows to view product images.
Shear Beam Load Cell for Floor Scales, Zemic Load Cell H8c with Capacity 1ton
| Price | Negotiable |
|---|---|
| Min Order | 5 Pieces |
| Availability | In Stock |
| Shipping From | Jiangsu, China |
| Popularity | 803 people viewed |
Model NO.:
H8C
Pattern:
Shear Beam Load Cell
Transform Type:
Resistance Strain
Out-Wire:
4-Wire
Output Signal Type:
Analog Type
Feature:
Corrosion Resistant
Material:
Alloy Steel
IP Rating:
IP67
Certification:
OIML
Customized:
Non-Customized
Accuracy:
C3
Cable Length:
4m or 6m
Capacity:
1t~10t
Application:
for Platform Scales
Trademark:
ZEMIC
Transport Package:
Carton
Specification:
2t, 5t, 10t
Origin:
China
Product Description
ZEMIC Load Cell H8C with Capacity 1ton
Main Features:
* Nickel plated alloy steel IP67 shear beam load cell
* Adhesive sealed
* Suitable platform weighing,bed weighing,etc.
* High accuracy
* High reliability
* Current calibrated(sc-option)
Wiring:
Specifications:
Dimensions:
Main Features:
* Nickel plated alloy steel IP67 shear beam load cell
* Adhesive sealed
* Suitable platform weighing,bed weighing,etc.
* High accuracy
* High reliability
* Current calibrated(sc-option)
Wiring:
Specifications:
| Maximum capacity(Emax) | 1.0t | ||||
| Accuracy class | C3 | ||||
| Approvals | OIML R60 C3 | ||||
| Maximum number of load cell intervals(nLC) | 3000 | ||||
| Ratio of minimum LC verification interval Y=Emax/Vmin | 10000 | ||||
| Combined error | ±0.020%FS | ||||
| Creep | ±0.016%FS/30min | ||||
| Temperature effect on sensitivity | ±0.011%FS/10ºC | ||||
| Temperature effect on zero | ±0.015%FS/10ºC | ||||
| Output sensitivity(=FS) | 3±0.003 mV/V 2.0±0.002 mV/V | ||||
| Input resistance | 350±3.5 Ω | ||||
| Onput resistance | 350±3.5 Ω | ||||
| Insulation resistance | ≥5000MΩ(50VDC) | ||||
| Zero balance | ±1.0%FS | ||||
| Compensated temperature | -10ºC~+40ºC | ||||
| Operating temperature | -35ºC~+70ºC | ||||
| Excitation,recommended voltage | 5V~12V(DC) | ||||
| Excitation maximum | 18V(DC) | ||||
| Safe overload | 150%FS | ||||
| Ultimate overload | 300%FS | ||||
| Recommended torque on fixation | M12: 100N.m; M18: 200N.m; M24: 700N.m | ||||
| Ingress protection(according to EN 60529) | IP67 | ||||
| ATEX classification(optional) | operating temperature: -20ºC~+40ºC | ||||
| II1G Ex ia II1C T4 | II1D Ex iaD20 T73ºC | II3G Ex nL II C T4 | |||
| "S1" output sensitivity is 2.0±0.002MV/V | |||||