Swipe or use the arrows to view product images.
Single Mode G652D Fiber Optic Cable Unitube Type GYXTW
| Price | $0.15 |
|---|---|
| Min Order | 3000 Meters |
| Availability | In Stock |
| Shipping From | Guangdong, China |
| Popularity | 297 people viewed |
Model NO.:
GYXTW Optic Fiber Cable
Application:
Communication, Optic Cable
Type:
Single-mode Fiber
Connection Structure:
Optic Cable
Material Shape:
Round Wire
Allowed Lateral Pressure:
100(N/100mm)<1000(N/100mm)
Allowed Tensile Strength:
1000N<10000N
Core:
Multicore
Certification:
RoHS, CE, ISO9001, Optic Cable
Brand:
OEM
Sheath Material:
PE
Product Name:
Optic Cable
Installation Style:
Duct & Direct Buried
Brand Name of Fiber:
as Your Requirement
Loose Tube Material:
PBT with Jelly
Waterblocking Material:
Water Blocking Tape or Filling Compound
Outer Sheath Material:
MDPE / HDPE /LSZH
Outer Sheath Color:
Black
Armour Material:
Corrugated Aluminium Tape
Color of Fiber and Loose Tube:
Red, Black, Yellow, Violet, Pink, Aqua
Color of Fiber /Loose Tube:
Blue, Orange, Green, Brown, Grey, White
Trademark:
TW-SCIE optic cable
Transport Package:
Wooden Drum
Specification:
SGS ROHS REACH ISO
Origin:
China (Mainland) Guangdong Dongguan
HS Code:
8544700000
Product Description
Single Mode G652D Fiber Optic Cable Unitube Type GYXTW
Description:
1. Single jelly compound filled loose tube containing up to 24 fibers
2. Waterproof tape between the steel tape and loose tube with jelly compound.
3. Double coated PE corrugated steel tape under PE sheath.
4. Parallel double steel wire as strength member.
5. Compact structure, light weight, steel tape armored excellent water-proof layer, good moisture.
General Specifications:
| Cable Type | Central Loose Tube fiber optic cable GYXTW |
| Fiber Type | SM G.652D |
| Application | Long-distance communication, LAN |
| Recommended installation methods | Aerial |
| Environment | Outdoor |
| Temperature Range | -40ºC to 70ºC |
Fiber Specifications:
| Technical parameter of ITU-T G.652D (B1.3) single-mode optical fiber | |||
| Characteristics | Conditions | Specified Values | Units |
| Optical Characteristics | |||
| Mode field diameter (MFD) | 1310nm 1550nm | 9.2±0.4 10.4±0.8 | µm µm |
| Cut-off wavelength (λcc) | ≤1260 | nm | |
| Attenuation coefficient | 1310nm 1383nm 1550nm | <0.35 <0.35 <0.22 | dB/km dB/km dB/km |
| Macro bending loss | φ75mm, 100circles, at 1550nm | ≤0.1 | dB |
| Attenuation non-uniformity | ≤0.05 | dB | |
| Dispersion coefficient | 1288~1339nm 1271~1360nm 1550nm | ≤3.5 ≤5.3 ≤18 | Ps/(nm.km) Ps/(nm.km) Ps/(nm.km) |
| Zero dispersion wavelength | 1300~1324 | nm | |
| Max zero dispersion slope | ≤0.093 | Ps/(nm2.km) | |
| Group index of refraction (typical value) | 1310nm 1550nm | 1.466 1.467 | |
| Geometric characteristic | |||
| Cladding diameter | 125.0±1.0 | µm | |
| Core/cladding concentricity error | ≤0.8 | µm | |
| Cladding non-circularity | ≤1.0 | % | |
| Coating diameter | 245.0±10 | µm | |
| Cladding/coating concentricity error | ≤12.0 | µm | |
| Coating non-circularity | ≤8 | % | |
| Diameter of colored coating | 250.0±15 | µm | |
| Mechanical characteristic | |||
| Curling (radius) | ≥4 | m | |
| Proof stress | >0.69 | Gpa | |
| Coating strip force | Average value Peak value | 1.0-5.0 1.3-8.9 | N N |
| Dynamic stress corrosion susceptibility parameter (nd value) | ≥20 | ||
Cable Design:
| Item | Description | |
| Model No | GYXTW | |
| 1. Fiber count | 4-18 | 20-24 |
| 2. Cable Diameter | 7.4±0.2mm | 8.0±0.2mm |
| 3. Cable Weight | 56KG | 69KG |
| 4. Loose Tube | ||
| -Material | PBT | |
| -Outer diameter | 2.0 mm | 2.6mm |
| -Thickness | 0.3mm | |
| -Type of filling compound | Jelly | |
| 5.Strength member | ||
| -Material | Steel wire | |
| -Outer diameter | 1.0 mm | |
| -Number | 2 pcs | |
| 6.Armor | ||
| -Material | Corrugated steel tape | |
| 7. Water-blocking system | ||
| -Material | Filling Compound | |
| 8.Outer Sheath | ||
| -Material | HDPE | |
| -Thickness | 1.8mm±0.2mm | |
| 9. Sheath marking | ||
| -Type of marking | Laser printing | |
Cable Performance:
| Item | Testing | Test Method | Test Result |
| 1 | Tensile strength IEC 60794-1-E1 | Long-term:1500N Short-tern: 600N Cable length: ≥50m | Loss change≤0.1dB@1550nm No fiber break and no sheath damage |
| 2 | Impact IEC 60794-1-E4 | Height: 1m Weight: 1kg Impact spot: ≥5 Impact cycle: at lease 3 cycle per spot | Loss change≤0.1dB@1550nm No fiber break and no sheath damage |
| 3 | Repeated Bending IEC 60794-1-E6 | Bending diameter: 25X the cable outer diameter Applied load: 25kg Bending cycle: 30times Bending speed: 1 cycle per 2s | Loss change≤0.1dB@1550nm No fiber break and no sheath damage |
| 4 | Torsion IEC 60794-1-E7 | Torsion length: 1m Applied load: 25kg Torsion angle: ±90 or +180 Twist cycle: ≥10 times | Loss change≤0.1dB@1550nm No fiber break and no sheath damage |
| 5 | Water Penetration IEC 60794-1-F5B | Water height: 1m Cable length: 3m Keeping time: 24hours | No water leaked from the opposite end of cable |
| 6 | Temperature IEC 60794-1-F1 | Temperature step:+20°C->-40°C°C >+70°C->+20°C Keeping time: 24hours per each step Cycle:2times | Loss change≤0.1dB@1550nm No fiber break and no sheath damage |
| 7 | Compound flow IEC 60794-1-E14 | Sample length: 30cm Temperature: 70ºC±2ºC Keeping time: 24hours | No compound flow |
| 8 | Sheath high voltage test | On line test DC 12t kV(t-sheath thickness mm) | No sheath broken down |
More Pictures:
Company Overview:
Related Products:
- Similar Products
$0.03
1000 Meters (MOQ)
Optical Fiber Connector Cable Multi-Mode mm Indoor Fibre
PUYANG YRT COMMUNICATIONS TECH CO., LTD.