Menu
Global B2B sourcing platform
Verified suppliers and manufacturers

Standby Industrial Genset Diesel Engine Generator Set Container 1000kw Generator with Cummins

Price $135000.00
Min Order 1 set
Availability In Stock
Shipping From Fujian, China
Popularity 274 people viewed
Model NO.:
GF/GFS-C1000KW
After-sales Service:
1 Year/1000 Hours
Warranty:
1 Year/1000 Hours
Type:
Micro-Computer Control Automatic Diesel Generator
Installation Method:
Fixed
Stroke:
Four Stroke
Cooling Method:
Water Cooling
Output Type:
AC Three Phase
Speed:
Speed
Conditions of Use:
Land Use
Usage:
Common Units
Landuse Type of Unit:
Low Noise Automation Type
Excitation Mode:
AC Rotating Exciter
Engine Model:
Qsk38-G5
Alternator:
Leroy Somer or Equivalent
Model:
Open Type/Silent Type/Trailer Type/Container Type
Fuel Tank:
8 Hours Base Fuel Tank
Controller:
Comap/Smartgen
Alternative:
Installing with ATS
Color:
Depends on
Frequency:
60Hz
Voltage:
220V/127V 440V/250V 480V 3 Phase
Trademark:
Gspark
Transport Package:
Container Delivery
Specification:
40ft Container
Origin:
Fujian
HS Code:
8502
Product Description



 
Company Profile

Brief introduction:  Genspark Equipment Co.,Ltd mainly Supply Diesel Generator Set and Gas Generator set,including in Famous brands,Deutz,Doosan,MTU,ShangHai Diesel,YangDong etc,raning from 10KW-2000KW Outputs.Having Open type,Silent type,Container type and trailer type generator models.


With more than 10 years experience on supplying Generator sets,We always offer Most Suitable Products for Customers Abroad.






 
Product Description







Product Data Sheet:




Diesel Power Generator Set  GF/GFS-C  Series
 


60Hz Diesel Generator with Cummins Power
 
Generator Set PerformanceEngine SpecificationOpen GensetSoundproof type
Genset Model60Hz OutputEngine ModelPower(Kw)Fuel Comsuption(100% Load)DimensionWeightDimensionWeight
60HzPrime StandbyKWL/HL*W*H (mm)KGL*W*H(mm)KG
KVAKWKVAKW
GF/GFS-C313312.5250344275NTA855-G128761.183000*1100*180027003500*1300*20003500
GF/GFS-C313313250350280NTA855-G1B313653100*1150*180030003500*1300*20003700
GF/GFS-C394394315433347NTA855-G335876.93100*1150*180030503500*1300*20003900
GF/GFS-C438438350481385KTA19-G239285.43450*1300*200040004200*1400*21005200
GF/GFS-C513513410564451KTA19-G34631003450*1300*200040004200*1400*21005200
GF/GFS-C563563450625500KTA19-G3A5071053500*1300*205043004500*1650*22505500
GF/GFS-C587587.5470687.5550KTAA19-G55331173700*1650*210046004500*1650*22505900
GF/GFS-C687687550756605KTAA19-G6A6001283700*1650*210046004500*1650*22505900
GF/GFS-C750906725997798KTA38-G28091694500*1800*245070505500*2000*29008200
GF/GFS-C100010008001100880KTA38-G2A915186.44500*1800*245072005500*2000*29008500
GF/GFS-C125011259001238990KTA38-G410072104800*1950*240079005800*2140*30809500
GF/GFS-C1136  12501000KTA38-G910001965800*2010*250085006800*2250*308010500
GF/GFS-C1200120096013201056QSK38-G510632205800*2010*250090006800*2250*308011000
GF/GFS-C13751375110015131210KTA50-G81200256.35800*2010*250090006800*2250*308011000
GF/GFS-C14501450116016251300KTA50-G912872735800*2010*250090006800*2250*308011000

 






 

 






 
Detailed Photos

 




Air Cooled Deutz Generator Set Model in Detail










 
After Sales Service

-------------------------------- -----------------------------------------------------After-Sale Part------------------------------------------------------------------------------------

Helpful tips on Generator Set Fault
When fault occurs during generator set running,could do primary judgement according to following tips.
IconIndicator LightReasonFault Analysis and Solve Method
High Water Temperature AlarmHigh Water Temperature AlarmWhen water Temperature has risen to a level higher than or equal to the sensor setting,the light is on.Normally,it is caused by lack of Water or Oil Shortage,or Overload. ----Should Automatically Shutdown Generator set Immediately.
Low Oil Pressure AlarmLow Oil Pressure AlarmWhen water Temperature has risen to a level higher than or equal to the sensor setting,the light is on.Normally,it is because of lack of Oil or Lubrication System Failure which caused by refueling or replacing the Oil Filter.----- When occurs this fault,should automatically shutdown generator set immediately.
Low Fuel Level AlarmLow Fuel Level AlarmWhen Fuel level has been detected by sensor fitted to the daily tank,the light is off.Normally,it caused by lacking of Water or Oil Shortage,or Overload.-----When occures this Fault,should automatically shutdown Generator set Immediately.
Battery Charger Fault AlarmBattery Charger Fault AlarmThe Charing System has fault while engine still running,the light is off.Battery Charging System Fault Caused.---The light in on at the initial Start,when the charger reaches a certain speed,the light is off.---This Failure will not lead to Automatic Shutdown Generating Unit.
Crank Failure AlarmCrank Failure AlarmWhen Generator set fail three times(or six times) in arow starting,the light is onIt is caused by Oil Supply System or Re-Start System Failure.
Overload or Breaker Tripping AlarmOverload or Breaker Tripping AlarmWhen Overloading or Short Circuit,the light is on. Tripping Circuit Breaker cause generator set load out.For this fault,it needs to load or unload some parts to eliminate short-Circuit,and then re-close the circuit Breaker.



Cerficates





Welcome your sending inquiry or directly contact!!


 
  • Similar Products
Full Page Contact Supplier