Model NO.:
XSP-3A1
After-sales Service:
1 Year
Warranty:
1 Year
Magnification:
40-400X
Type:
Biological
Number of Cylinder:
Monocular
Mobility:
Portable
Stereoscopic Effect:
Without Stereoscopic Effect
Kind of Light Source:
Concave-Plam
Shape:
Concave-Plam Reflector Dia 40mm
Usage:
Teaching
Principle:
Optics
Principle of Optics:
Polarizing Microscope
Trademark:
SHUN MA / OEM
Transport Package:
Wooden / Foam box
Specification:
220V, 50HZ, 20W
Origin:
YUYAO, ZHEJIANG, CHINA
HS Code:
9011800090
Product Description
Product Description

Monocular microscope for student XSP-3A1
Product Introduction
The monocular microscope series for student are available in a variety of specifications.

Before use

  1. As the microscope is a precision instrument, always handle it with care, avoiding impact or abrupt movement during transportation.
  2. Do not let the microscope emerge in the sun directly. Keep it in a dry and clean place. Avoid high temperature and acute shake. Following environment is required: Indoor temperature:0ºC~40ºC,Max relative humidity:85%.
  3. Avoiding impact the definition of the image,do not leave feculence and fingerprints on the lens surfaces.
  4. Before using, examine to ensure the power supply is consistent with the rating voltage.
Product Specification
ModelXSP-3A1XSP-3A2XSP-3A3XSP-200X
Total Magnification4X~400X200X
EyepieceWF10X12.5X
Objective4X, 10X, 40X(S)16X
Eyepiece TubeMonocular vertical tubeMonocular, 45° inclined tube rotatable 360°Monocular vertical tube
IlluminationConcave-plam reflector. Dia Φ 40mm
Coarse Adjustment Range20mm
Fine Adjustment Range 1.4mm~1.6mm 
Working Stage100x90mm
OptionalElectrical Illumination(110V/20W,220V/20W Optional)

ModelXSP-01XSP-02L101XSP-13A
Total Magnification40X~500X40X~640X25X~675X50X~1250X
Eyepiece10X,12.5X10X,16X5X,10X,15X5X,10X,12.5X
Objective4X,10X,40X5X,10X,45X10X,40X,100X
Eyepiece TubeMonocular vertical tube
IlluminationConcave-plam reflector. Dia Φ 50mm
Coarse Adjustment Range50mm
Fine Adjustment Range1.8mm~2.2mm
Working Stage110x120mmΦ120mm110x120mm
Condenser N.A.1.25 abc condenser with changeable diaphragm,moving scale and filter
OptionalElectrical Illumination(110V/20W,220V/20W Optional)

How to use
  1. Place the specimen slide on the stage,position the spot of the slide you wish to observe to the center hole on the stage and clamp it with slide clips.
  2. Mount objectives on revolving nosepiece and eyepiece on eyepiece tube respectively.
  3. Turn reflecting mirror to the source of light until the light illuminated into the eyepiece tube and the field of view becomes visible,then adjust the aperture of iris diaphragm(disc) to secure clear image.
  4. When focusing,first adjust focus wheel forward to lower the main tube until the objective gets close to the specimen slide,so as to avoid any possible damage.Then start to observe the eyepiece by adjusting the focus wheel until a sharp image is obtained.
  5. The stand can be adjusted when necessary to obtain the best angle for the light source and for the comfort of observation.
Product feature and application

The monocular microscope series for student are designed for general research of biology and bacteriology in hospitals,labs,research institutions and universities as well as for clinical testing and teaching demonstrations.By multiplying the power of the objective and eyepiece used will allow the microscope to offer you required magnification for observation.

Maintenance and precautions
  1. The monocular microscope series for student should be replaced in the wooden box after use and it should be stored in a cool.dry place free from acid and alkali fumes.
  2. The monocular microscope series for student has been carefully tested and checked.The objective and eyepiece should not be disassembled. If there is any dust,blow it off by means of a blower, and then brush it with a soft hair-brush. Oil stains can be removed by using a piece of fine clean soft cloth moistured with a little xylol.
  3. Any dust on the mechanical paets of the instrument should be wiped off first and then rubbed with a clean fine cloth.Unvarnished sliding part should be applied with a thin layer noncorrosive lubricand.
  4. When the coarse adjustment mechanism is found too tight or too loose for the elevation or lowering, hold the coarse adjustment knob with one hand and turn another knob with the other hand Loosen it when it is too tight and tighten it when it is too loose.A suitable adjustment will enable it to operate fitly.
  5. The objectives should be covered and replaced in a box to avoid dirt or crushing, after use.
  6. The 100x objective should be rubbed over with clean fine cloth moistured with xylol.
Detailed Photos

  • Similar Products
Full Page Contact Supplier