Swipe or use the arrows to view product images.
TCM-PV Fully Automatic Double Plate Thermal Conductivity Tester (protected hot plate method)
| Price | $500.00 |
|---|---|
| Min Order | 1 Piece |
| Availability | In Stock |
| Shipping From | Hunan, China |
| Popularity | 556 people viewed |
Model NO.:
TCM-PV
After-sales Service:
Free Spare Parts
Warranty:
One Year
Model:
Tcm-PV (Upgrade of Drh-III, Drh-V)
Thermal Conductivity Measuring Range:
0.001~3.000 W/M.K,
Measurement Accuracy:
±2%
Power Supply:
220V 50Hz.500W
Whole Process Test Time:
60 Minutes.
Net Weight:
100kg
Trademark:
Xiangyi
Transport Package:
Plywood Packing
Specification:
550 x455x1505mm
Origin:
China
Product Description
TCM-PV fully automatic dual-plate thermal conductivity tester, the flat-plate thermal conductivity meter meets the high-precision testing requirements for material thermal conductivity of the materials testing and research department. It has a computer to automatically measure thickness, automatically pressurize, and measure thermal conductivity under different pressures. Fully automatic data collection, data processing, report printing, and data storage. It has the advantages of short measurement time, accurate data, good repeatability and high degree of automation.
Purpose
This thermal conductivity meter mainly tests homogeneous plate materials such as plastics, glue, glass, fiber, benzene board, extruded board, foam concrete, hollow glass, wooden boards, various insulation materials, etc. It can also measure granular materials and bulk materials. soft materials and other materials.
Features
Applicable standards
Dimensions and weight
1. Host: (L × W × H) 550 × 455 × 1505mm, net weight: 100Kg.
2. Precision low-temperature constant water bath: (L × W × H) 305 × 355 × 530mm, net weight: 35Kg
CONFIGURATION
Purpose
This thermal conductivity meter mainly tests homogeneous plate materials such as plastics, glue, glass, fiber, benzene board, extruded board, foam concrete, hollow glass, wooden boards, various insulation materials, etc. It can also measure granular materials and bulk materials. soft materials and other materials.
Features
- Online temperature calibration: Unique technology, calibration instrument is simple and fast, and the accuracy is increased by more than 3 times.
- The whole process testing time is greatly shortened.
- Large measuring range: range 0.001-3.00w/(m.k).
- Automatic thickness measurement: Computer automatically measures thickness to reduce human error.
- Automatic pressurization system: The computer automatically pressurizes, which can test the thermal conductivity under different pressures. It is more scientific, more data-based and has better repeatability than manual pressurization.
- Various measurement types: In addition to measuring hard plates, the company's various accessories can be selected to measure a variety of special materials. For example: granular materials and bulk materials.
Applicable standards
- "Determination of steady-state thermal resistance and related characteristics of thermal insulation materials";
- "Test method for thermal conductivity of plastics-heat-protected plate method" ; Measurement of thermal conductivity of polyurethane rigid foam materials specified in "Polystyrene foam for thermal insulation";
- "Extruded polystyrene foam for thermal insulation (XPS)" )" Measurement of thermal conductivity of extruded polystyrene foam plastics;
- "Test Method for Thermal Conductivity of Fiber Reinforced Plastics";
- "Flexible Foam Rubber and Plastic Insulation Products";
| MODEL | TCM-PV (upgrade of DRH-III, DRH-V) |
| Thermal conductivity measuring range | 0.001~3.000 W/m.K, |
| Measurement accuracy | ±2%, repeatability ±1% |
| Hot surface temperature range | RT ~ 150°C, resolution 0.01°C RT ~ 300°C is optional |
| Cold surface temperature range | 0~60ºC, resolution 0.01ºC -5~60ºC is optional |
| Thickness measurement range | 0~100mm, resolution 0.001mm automatic thickness measurement |
| Pressure measurement range | 0~500N, resolution 0.1N |
| Test piece size | 300*300* (5~50) mm (other size can be customized) |
| Computer & sofware | Full computer automatic detection and data processing system, compatible with general-purpose computers. |
| Whole process test time | 60 minutes. |
| Power supply | 220V 50HZ.500W |
Dimensions and weight
1. Host: (L × W × H) 550 × 455 × 1505mm, net weight: 100Kg.
2. Precision low-temperature constant water bath: (L × W × H) 305 × 355 × 530mm, net weight: 35Kg
CONFIGURATION
| Item name | Qty |
| Thermal conductivity tester host | 1 set |
| Analysis software (English versions) | 1 copy |
| Precision low-temperature water bath | 1 set |
| Lenovo computer (user can choose); | 1 set |
| Standard samples | 2 pcs |
| Accessories (grease, paste and powder test boxes, Forming stamping mold). | 1 set |
- Similar Products
$4792.00
1 Piece (MOQ)
Fluoride Ion Detection System for Wastewater Treatment Plant
Santo (China) Limited
$150000.00
1 Piece (MOQ)
Horizontal Fire Resistance Test Furnace by En 1363 and ISO 834
Chongqing Advanced Technology Co., Ltd.
$18500.00
1 Set (MOQ)
Libs Analyzer for Fabrication and PMI
WUXI JINYIBO INSTRUMENT TECHNOLOGY CO., LTD.