Swipe or use the arrows to view product images.
TD1880 Advanced High Precision Multifunction Calibrator
| Price | $75000.00 |
|---|---|
| Min Order | 1 Piece |
| Availability | In Stock |
| Shipping From | Hunan, China |
| Popularity | 451 people viewed |
Model NO.:
TD1880
After-sales Service:
24 Hours
Warranty:
365 Days
Installation:
Portable
Display Mode:
Digital
Accuracy:
0.005%
Theory:
Electronic Meter
Power Source:
AC
Connection Type:
USB
Maximum Scale:
1999999
Range Conversion Type:
AUTO/MAN RANGZ
Additional Measuring Item:
Capacitance
Display:
LCD
Trademark:
TUNKIA
Transport Package:
Aviation Packaging
Origin:
Chn
HS Code:
9030899090
Product Description
TD1880 High-Precision Multi-Product Calibrator
Introduction
Reference
Features
Specification
AC Voltage Output
AC Current Output
DC Voltage Output
DC Current Output
AC/DC Power Output
Capacitance
Resistance
Thermal Resistance (RTD)
Thermocouple (TC)
Pulse
DC Small Signal Measurement (Option)
Introduction
- TD1880, a wide-range, multi-value and high-precision calibrator, can accurately output ultra-precision AC/DC voltage, current, phase adjustment and power, and also has the functions of pulse output and simulating DC resistance, thermocouple (TC), thermal resistance (RTD) and capacitance. Applied to calibrate 6½ and below digits multimeters or other electrical measuring instruments.
Reference
- JJG 124-2005 Verification Regulation of Amperemeters, Voltmeters, Wattmeters and Ohmmeters.
- JJF 1587-2016 Calibration Specification for Multimeters
- JJF 1284-2011 Calibration Specification of Calibrators for Electrical Meters
- JJF 1638-2017 Calibration specification of multifunctional standard source
Features
- Electrical Parameters Output: Voltage is up to 1100 V, current is up to 20.5 A at a frequency 10 Hz ~ 500 kHz.
- Resistance Simulation: Continuously variable range, 1 Ω ~ 1100 MΩ, pulse output range: 1 Hz ~ 2 MHz.
- The output current has high stability (the typical value is better than 10 ppm/h) and high accuracy (the typical value is 50 ppm/a), and its measurement accuracy is higher than the international similar products.
- Value Adjustment Method: Fixed-point, rotary encoder, step and potentiometer (option).
- Output Switch: The output can be turned on/off arbitrarily by one-touch operation.
- TC and RTD simulation: Support for simulation of up to 8 types of TC and 6 types of RTD.
- Strong load capacity of AC, can drive various types of analogue meters and digital meters, so the applicable range of measured instruments is very wide.
- The protection of voltage and current sources ensures high reliability under complex conditions.
- Excellent Human-Computer Interaction: Large LCD touch screen display, touch and button operation modes, easy for users to measure manually.
- Transmitter Measurement (Option): Measure the secondary DC signal of the transmitters.
- Proprietary Software (Option): Support the calibration of the checked meters by semi-automatic or full-automatic, data management and report export.
Specification
AC Voltage Output
| Range | Resolution | Frequency (Hz) | Accuracy (k = 2, ppm*RD +μV) | Max. Load Current (mA) | |
| 90 Days (23 ±5) °C | 1 Year (23 ±5) °C | ||||
| 30 mV | 100 nV | 10 ≤ F≤ 45 | 600 + 6 | 800 + 6 | 50 |
| 45 < F < 400 | 80 + 5 | 100 + 5 | |||
| 400 < F < 10 k | 80 + 10 | 100 + 10 | |||
| 10 k < F < 20 k | 160 + 10 | 200 + 10 | |||
| 20 k < F < 50 k | 800 + 10 | 1000 + 10 | |||
| 50 k < F < 100 k | 2800 + 12 | 3500 + 12 | |||
| 100 k < F < 500 k | 6000 + 50 | 8000 + 50 | |||
| 100 mV | 1 μV | 10 ≤ F≤ 45 | 250 + 8 | 300 + 8 | 50 |
| 45 < F < 400 | 80 + 5 | 100 + 5 | |||
| 400 < F < 10 k | 80 + 10 | 100 + 10 | |||
| 10 k < F < 20 k | 80 + 10 | 200 + 10 | |||
| 20 k < F < 50 k | 280 + 10 | 350 + 10 | |||
| 50 k < F < 100 k | 640 + 10 | 800 + 10 | |||
| 100 k < F < 500 k | 1600 + 70 | 2000 + 70 | |||
| 300 mV | 1 μV | 10 ≤ F≤ 45 | 250 + 8 | 300 + 8 | 100 |
| 45 < F < 10 k | 80 + 10 | 100 + 10 | |||
| 10 k < F < 20 k | 80 + 10 | 200 + 10 | |||
| 20 k < F < 50 k | 280 + 10 | 350 + 10 | |||
| 50 k < F < 100 k | 640 + 10 | 800 + 10 | |||
| 100 k < F < 500 k | 1600 + 70 | 2000 + 70 | |||
1 V | 10 μV | 10 ≤ F≤ 45 | 250 + 50 | 300 + 50 | 100 |
| 45 < F < 400 | 40 + 20 | 50 + 20 | |||
| 400 < F < 10 k | 80 + 20 | 100 + 20 | |||
| 10 k < F < 20 k | 160 + 20 | 200 + 20 | |||
| 20 k < F < 50 k | 280 + 20 | 350 + 20 | |||
| 50 k < F < 100 k | 640 + 20 | 800 + 20 | |||
| 100 k < F < 500 k | 2000 + 600 | 2400 + 600 | |||
| 3 V | 10 μV | 10 ≤ F≤ 45 | 250 + 50 | 300 + 50 | 100 |
| 45 < F < 400 | 40 + 50 | 50 + 50 | |||
| 400 < F < 2 k | 64 + 50 | 80 + 50 | |||
| 2 k < F < 10 k | 80 + 50 | 100 + 50 | |||
| 10 k < F < 20 k | 160 + 50 | 200 + 50 | |||
| 20 k < F < 50 k | 280 + 50 | 350 + 50 | |||
| 50 k < F < 100 k | 640 + 50 | 800 + 50 | |||
| 100 k < F < 500 k | 2000 + 600 | 2400 + 600 | |||
| 10 V | 100 μV | 10 ≤ F≤ 15 | 250 + 30000 | 300 + 30000 | 100 |
| 15 < F < 45 | 250 + 650 | 300 + 650 | |||
| 45 < F < 400 | 40 + 150 | 50 + 150 | |||
| 400 < F < 2 k | 64 + 150 | 80 + 150 | |||
| 2 k < F < 10 k | 80 + 150 | 100 + 150 | |||
| 10 k < F < 20 k | 160 + 150 | 200 + 150 | |||
| 20 k < F < 50 k | 280 + 150 | 350 + 150 | |||
| 30 V | 100 μV | 10 ≤ F≤ 15 | 250 + 80000 | 300 + 30000 | 250 |
| 15 < F < 45 | 250 + 650 | 300 + 650 | |||
| 45 < F < 400 | 40 + 500 | 50 + 500 | |||
| 400 < F < 2 k | 64 + 500 | 80 + 500 | |||
| 2 k < F < 10 k | 80 + 500 | 100 + 500 | |||
| 10 k < F < 20 k | 160 + 500 | 200 + 500 | |||
| 20 k < F < 50 k | 280 + 500 | 350 + 500 | |||
| 100 V | 1 mV | 15 < F < 45 | 250 + 2000 | 300 +2000 | 250 |
| 45 < F < 400 | 40 + 1000 | 50 +1000 | |||
| 400 < F < 2 k | 64 + 1000 | 80 + 1000 | |||
| 2 k < F < 10 k | 80 + 1000 | 100 + 1000 | |||
| 10 k < F < 20 k | 160 + 1000 | 200 + 1000 | |||
| 20 k < F < 50 k | 280 + 1000 | 350 + 1000 | |||
| 300 V | 1 mV | 15 < F < 45 | 250 + 6000 | 300 + 6000 | 100 |
| 45 < F < 400 | 50 + 5000 | 50 + 5000 | |||
| 400 < F < 2 k | 80 + 5000 | 80 + 5000 | |||
| 2 k < F < 10 k | 80 + 5000 | 100 + 5000 | |||
| 10 k < F < 20 k | 160 + 5000 | 200 + 5000 | |||
| 20 k < F < 50 k | 280 + 5000 | 350 + 5000 | |||
| 1000 V | 10 mV | 45 ≤ F≤ 400 | 80 + 10000 | 100 + 10000 | 30 |
| 400 < F < 2 k | 96 + 10000 | 120 + 10000 | |||
| 2 k < F < 10 k | 120 + 10000 | 150 + 10000 | |||
- Output Range: 3 mV ~ 1100 V; Display: 7 digits;
- Distortion: <0.5 %;<1 % @ 10 mV…1 V ranges
- Protection: Short-circuit protection, overload protection.
AC Current Output
| Range | Resolution | Frequency (Hz) | Accuracy (k = 2, ppm*RD +μV) | Max. Load Current (mA) | |
| 90 Days (23 ±5) °C | 1 Year (23 ±5) °C | ||||
| 300 μA | 1 nA | 10 ≤ F≤ 20 | 400 + 0.2 | 500 + 0.2 | 30 |
| 20 < F < 45 | 300 + 0.1 | 350 + 0.1 | |||
| 45 < F < 400 | 240 + 0.1 | 300 + 0.1 | |||
| 400 < F < 2 k | 320 + 0.2 | 400 + 0.2 | |||
| 2 k < F < 10 k | 400 + 0.5 | 500 + 0.5 | |||
| 10 k < F < 20 k | 4000 + 0.6 | 5000 + 0.6 | |||
| 20 k < F < 50 k | 6400 + 0.7 | 8000 + 0.7 | |||
| 1 mA | 10 nA | 10 ≤ F≤ 20 | 400 + 0.5 | 500 + 0.5 | 30 |
| 20 < F < 45 | 200 + 0.1 | 250 + 0.1 | |||
| 45 < F < 400 | 160 + 0.1 | 200 + 0.1 | |||
| 400 < F < 2 k | 160 + 0.2 | 200 + 0.2 | |||
| 2 k < F < 10 k | 240 + 0.5 | 300 + 0.5 | |||
| 10 k < F < 20 k | 2400 + 0.6 | 3000 + 0.6 | |||
| 20 k < F < 50 k | 5600 + 0.7 | 7000 + 0.7 | |||
| 3 mA | 10 nA | 10 ≤ F≤ 20 | 400 + 1.5 | 500 + 1.5 | 30 |
| 20 < F < 45 | 200 + 0.1 | 250 + 0.1 | |||
| 45 < F < 400 | 160 + 0.1 | 200 + 0.1 | |||
| 400 < F < 2 k | 160 + 0.2 | 200 + 0.2 | |||
| 2 k < F < 10 k | 240 + 0.5 | 300 + 0.5 | |||
| 10 k < F < 20 k | 1600 + 0.6 | 2000 + 0.6 | |||
| 20 k < F < 50 k | 4800 + 0.7 | 6000 + 0.7 | |||
| 10 mA | 100 nA | 10 ≤ F≤ 20 | 400 + 5 | 500 + 5 | 30 |
| 20 < F < 45 | 200 + 0.5 | 250 + 0.5 | |||
| 45 < F < 400 | 80 + 0.5 | 100 + 0.5 | |||
| 400 < F < 2 k | 160 + 1 | 200 + 1 | |||
| 2 k < F < 10 k | 400 + 2 | 500 + 2 | |||
| 10 k < F < 20 k | 1600 + 3 | 2000 + 3 | |||
| 20 k < F < 50 k | 4800 + 4 | 6000 + 4 | |||
| 30 mA | 100 nA | 10 ≤ F≤ 20 | 400 + 15 | 500 + 15 | 30 |
| 20 < F < 45 | 200 + 2 | 250 + 2 | |||
| 45 < F < 400 | 80 + 2 | 100 + 2 | |||
| 400 < F < 2 k | 160 + 3 | 200 + 3 | |||
| 2 k < F < 10 k | 400 + 5 | 500 + 5 | |||
| 10 k < F < 20 k | 1600 + 6 | 2000 + 6 | |||
| 20 k < F < 50 k | 4800 + 7 | 6000 + 7 | |||
| 100 mA | 1 μA | 10 ≤ F≤ 20 | 400 + 50 | 500 + 50 | 30 |
| 20 < F < 45 | 200 + 5 | 250 + 5 | |||
| 45 < F < 400 | 40 + 5 | 50 + 5 | |||
| 400 < F < 2 k | 80 + 10 | 100 + 10 | |||
| 2 k < F < 10 k | 160 + 20 | 200 + 20 | |||
| 10 k < F < 20 k | 800 + 30 | 1000 + 30 | |||
| 20 k < F < 30 k | 2400 + 40 | 3000 + 40 | |||
| 30 k < F < 50 k | 5000 + 40 | 6000 + 40 | |||
| 1 A | 10 μA | 10 ≤ F≤ 20 | 400 + 500 | 500 + 500 | 15 |
| 20 < F < 45 | 200 + 20 | 250 + 20 | |||
| 45 < F < 400 | 40 + 50 | 50 + 50 | |||
| 400 < F < 2 k | 50 + 100 | 50 + 100 | |||
| 2 k < F < 10 k | 160 + 500 | 200 + 500 | |||
| 10 k < F < 20 k | 800 + 600 | 1000 + 600 | |||
| 20 k < F < 30 k | 2400 + 700 | 3000 + 700 | |||
| 3 A | 10 μA | 10 ≤ F≤ 20 | 400 + 1500 | 500 + 1500 | 10 |
| 20 < F < 45 | 200 + 100 | 250 + 100 | |||
| 45 < F < 400 | 40 + 100 | 50 + 100 | |||
| 400 < F < 2 k | 80 + 100 | 100 + 100 | |||
| 2 k < F < 10 k | 160 + 500 | 200 + 500 | |||
| 10 A | 100 μA | 45 < F < 400 | 40 + 200 | 50 + 200 | 2.5 |
| 400 < F < 2 k | 80 + 200 | 100 + 200 | |||
| 2 k < F < 10 k | 160 + 500 | 200 + 500 | |||
| 20.5 A | 100 μA | 45 ≤ F≤ 400 | 80 + 600 | 100 + 600 | 2 |
| 400 < F < 2 k | 80 + 600 | 100 + 600 | |||
| 2 k < F < 5 k | 160 + 1500 | 200 + 1500 | |||
- Output Range: 30 μA ~ 20.5 A; Display: 7 digits;
- Distortion: <0.5 %;<1 % @ 300 μA…10 mA ranges
- Protection: Short-circuit protection, overload protection.
DC Voltage Output
| Range | Accuracy (K = 2) (ppm*RD + μV) | Max. Load Current (mA) | Ripple Coefficient (%) | ||
| 24 Hours | 90 Days | 1 Year | |||
| 30 mV | 15 + 2 | 24 + 2 | 30 + 2 | 50 | < 0.5 |
| 100 mV | 12 + 2 | 20 + 2 | 25 + 2 | 50 | < 0.5 |
| 300 mV | 10 + 2 | 16 + 2 | 20 + 2 | 100 | < 0.5 |
| 1 V | 10 + 2 | 16 + 2 | 20 + 2 | 100 | < 0.5 |
| 3 V | 8 + 5 | 12 + 5 | 15 + 5 | 100 | < 0.5 |
| 10 V | 8 + 10 | 12 + 10 | 15 + 10 | 100 | < 0.5 |
| 30 V | 8 + 20 | 12 + 20 | 15 + 20 | 250 | < 0.5 |
| 100 V | 10 + 100 | 16 + 100 | 20 + 100 | 250 | < 0.5 |
| 300 V | 10 + 300 | 16 + 300 | 20 + 300 | 100 | < 0.5 |
| 1000 V | 10 + 1500 | 16 + 1500 | 20 + 1500 | 30 | < 0.5 |
- Output Range: ±(3 mV ~ 1100 V); Resolution: 0.0005 %*RG; Display: 7 digits
- Range Switching: Automatic or Manual.
DC Current Output
| Range | Accuracy (K = 2) (ppm*RD + ppm*RG) | Max. Load Voltage (V) | Ripple Coefficient (%) | ||
| 24 Hours | 90 Days | 1 Year | |||
| 30 μA | 50 + 0.01 | 80 + 0.01 | 100 + 0.01 | 11 | < 0.5 |
| 100 μA | 50 + 0.02 | 80 + 0.02 | 100 + 0.02 | 11 | < 0.5 |
| 300 μA | 50 + 0.02 | 80 + 0.02 | 100 + 0.02 | 11 | < 0.5 |
| 1 mA | 25 + 0.05 | 40 + 0.05 | 50 + 0.05 | 11 | < 0.5 |
| 3 mA | 25 + 0.05 | 40 + 0.05 | 50 + 0.05 | 11 | < 0.5 |
| 10 mA | 25 + 0.2 | 40 + 0.2 | 50 + 0.2 | 11 | < 0.5 |
| 30 mA | 25 + 0.5 | 40 + 0.5 | 50 + 0.5 | 11 | < 0.5 |
| 100 mA | 25 + 1 | 40 + 1 | 50 + 1 | 11 | < 0.5 |
| 1 A | 25 + 20 | 40 + 20 | 50 + 20 | 4 | < 0.5 |
| 3 A | 25 + 50 | 40 + 50 | 50 + 50 | 4 | < 0.5 |
| 10 A | 25 + 200 | 40 + 200 | 50 + 200 | 4 | < 0.5 |
| 20.5 A | 30 + 600 | 48 + 600 | 60 + 600 | 3.5 | < 0.5 |
- Output Range: ±(3 μA ~ 20.5 A); Resolution: 0.0005 %*RG; Display: 7 digits
- Range Switching: Automatic or Manual.
AC/DC Power Output
| DC Power | Range | Combination of DC voltage range and DC current range. |
| Accuracy | DC voltage accuracy + DC current accuracy. | |
| AC Power (45 Hz ~ 65 Hz) | Range | Combination of 30 V...300 V range and 10 mA…30 A range. |
| Accuracy | Range of 10 mA…30 mA: 0.05 %*FS | |
| Range of 100 mA…30 A: 0.02 %*FS | ||
| Power Factor | -1.0000…0.0000…+1.0000 |
- Active Power (|cosφ| ≥0.5), Reactive Power (|sinφ| ≥0.5)
Capacitance
| Range | Accuracy (k = 2) (%*RD+ nF or μF) | Resolution | Allowable Frequency |
| 1.1 nF ~ 3.2999 nF | 0.5 + 0.04 nF | 0.1 pF | 10 Hz ~ 3 kHz |
| 3.3 nF ~ 10.9999 nF | 0.25 + 0.04 nF | 0.1 pF | 10 Hz ~ 1 kHz |
| 11 nF ~ 32.9999 nF | 0.25 + 0.4 nF | 0.1 pF | 10 Hz ~ 1 kHz |
| 33 nF ~ 109.999 nF | 0.25 + 0.4 nF | 1 pF | 10 Hz ~ 1 kHz |
| 110 nF ~ 329.999 nF | 0.25 + 0.3 nF | 1 pF | 10 Hz ~ 1 kHz |
| 330 nF ~ 1.09999 μF | 0.25 + 1 nF | 10 pF | 10 ~ 600 Hz |
| 1.1 μF ~ 3.29999 μF | 0.25 + 3 nF | 10 pF | 10 ~ 300 Hz |
| 3.3 μF ~ 10.9999 μF | 0.25 + 10 nF | 100 pF | 10 ~ 150 Hz |
| 11 μF ~ 32.9999 μF | 0.40 + 30 nF | 100 pF | 10 ~ 120 Hz |
| 33 μF ~ 109.999 μF | 0.45 + 100 nF | 1 nF | 10 ~ 80 Hz |
| 110 μF ~ 329.999 μF | 0.45 + 300 nF | 1 nF | 0 ~ 50 Hz |
| 330 μF ~ 1.09999 mF | 0.45 + 1 μF | 10 nF | 0 ~ 20 Hz |
| 1.1 mF ~ 3.29999 mF | 0.45 + 3 μF | 10 nF | 0 ~ 6 Hz |
| 3.3 mF ~ 10.9999 mF | 0.45 + 10 μF | 100 nF | 0 ~ 2 Hz |
| 11 mF ~ 30 mF | 0.75 + 30 μF | 100 nF | 0 ~ 0.6 Hz |
Resistance
| Range | Allowable Current | Accuracy (k = 2), ppm*RD +Ω | ||
| 24 Hours | 90 Days | 1 Year | ||
| 10 Ω | 1 mA ~ 150 mA | 20 + 0.01 | 32 + 0.01 | 40 + 0.01 |
| 20 Ω | 1 mA ~ 150 mA | 15 + 0.015 | 24 + 0.015 | 30 + 0.015 |
| 100 Ω | 1 mA ~ 80 mA | 12 + 0.015 | 20 + 0.015 | 25 + 0.015 |
| 300 Ω | 1 mA ~ 40 mA | 12 + 0.02 | 20 + 0.02 | 25 + 0.02 |
| 1 kΩ | 1 mA ~ 20 mA | 12 + 0.02 | 20 + 0.02 | 25 + 0.02 |
| 3 kΩ | 0.1 mA ~ 6 mA | 12 + 0.2 | 20 + 0.2 | 25 + 0.2 |
| 10 kΩ | 0.1 mA ~ 2 mA | 12 + 0.2 | 20 + 0.2 | 25 + 0.2 |
| 30 kΩ | 10 μA ~ 600 μA | 15 + 1 | 24 + 1 | 30 + 1 |
| 100 kΩ | 10 μA ~200 μA | 15 + 1 | 24 + 1 | 30 + 1 |
| 300 kΩ | 1 μA ~ 60 μA | 17 + 10 | 28 + 10 | 35 + 10 |
| 1 MΩ | 1 μA ~ 20 μA | 17 + 10 | 28 + 10 | 35 + 10 |
| 3 MΩ | 250 nA ~ 6 μA | 30 + 150 | 48 + 150 | 60 + 150 |
| 10 MΩ | 250 nA ~ 2 μA | 65 + 250 | 104 + 250 | 130 + 250 |
| 30 MΩ | 25 nA ~ 600 nA | 125 + 2.5 k | 200 + 2.5 k | 250 + 2.5 k |
| 100 MΩ | 25 nA ~ 200 nA | 250 + 3 k | 400 + 3 k | 500 + 3 k |
| 300 MΩ | 2.5 nA ~ 60 nA | 1,5 k + 0.1 M | 2.4 k + 0.1 M | 3 k + 0.1 M |
| 1000 MΩ | 1 nA ~ 20 nA | 7.5 k + 0.5 M | 12 k + 0.5 M | 15 k + 0.5 M |
- Output Range of Resistance: 0 Ω ~ 1100 MΩ; Resolution: 0.0004 %*RG; Display: 7 digits
Thermal Resistance (RTD)
| Type | Temperature Range (°C) | Accuracy (k = 2) (°C) | |
| 90 Days | 1 Year | ||
| Pt385, 100 Ω | -200 ~ 0 | 0.05 | 0.05 |
| 0 ~ 300 | 0.08 | 0.08 | |
| 300 ~ 850 | 0.12 | 0.12 | |
| Pt385,200 Ω | -200 ~ 250 | 0.04 | 0.04 |
| 250 ~ 630 | 0.10 | 0.15 | |
| Pt385,500 Ω | -200 ~ -30 | 0.36 | 0.40 |
| -30 ~ 630 | 0.10 | 0.11 | |
| Pt385,1000 Ω | -200 ~ 0 | 0.027 | 0.03 |
| 0 ~ 300 | 0.054 | 0.060 | |
| 300 ~ 600 | 0.063 | 0.070 | |
| CU50 | -50 ~ 150 | 0.09 | 0.09 |
| CU100 | -50 ~ 150 | 0.045 | 0.045 |
Thermocouple (TC)
| Type | Temperature Range (°C) | Accuracy (k = 2) (°C) | |
| 90 Days | 1 Year | ||
| B | 410 ~ 600 | 0.30 | 0.35 |
| 600 ~ 900 | 0.30 | 0.31 | |
| 900 ~ 1800 | 0.26 | 0.30 | |
| E | -200 ~ 0 | 0.10 | 0.11 |
| 0 ~ 600 | 0.07 | 0.08 | |
| 600 ~ 1000 | 0.09 | 0.10 | |
| J | -200 ~ -100 | 0.12 | 0.13 |
| -100 ~ 750 | 0.09 | 0.09 | |
| 750 ~ 1200 | 0.10 | 0.10 | |
| K | -200 ~ -100 | 0.15 | 0.20 |
| -100 ~ 1000 | 0.10 | 0.10 | |
| 1000 ~ 1370 | 0.12 | 0.12 | |
| N | -200 ~ -100 | 0.20 | 0.25 |
| -100 ~ 400 | 0.12 | 0.12 | |
| 400 ~ 1300 | 0.10 | 0.12 | |
| R | -50 ~ 50 | 0.30 | 0.40 |
| 50 ~ 300 | 0.28 | 0.32 | |
| 300 ~ 1000 | 0.22 | 0.23 | |
| 1000 ~ 1750 | 0.25 | 0.25 | |
| S | -50 ~ 50 | 0.30 | 0.40 |
| 50 ~ 300 | 0.31 | 0.34 | |
| 300 ~ 1000 | 0.24 | 0.24 | |
| 1000 ~ 1750 | 0.22 | 0.23 | |
| T | -200 ~ -100 | 0.17 | 0.25 |
| -100 ~ 0 | 0.08 | 0.11 | |
| 0 ~ 400 | 0.08 | 0.08 | |
Pulse
- Frequency Range: 1 Hz ~ 2 MHz, TTL Level
- Resolution: 0.001 %*RG
- Accuracy: ±(0.002 %*RD + 20 μHz)
- Jitter: <20 ns
DC Small Signal Measurement (Option)
- Range: 1 V, 10 V, 2 mA, 20 mA
- Measuring Range: ± (0 ~12 V);± (0 ~ 24 mA)
- Accuracy: ±(0.006 %*RD + 0.004 %*RG)
- Notes: Applied to measure the secondary DC signal of the transmitters.
- Similar Products
Negotiable
50 Pieces (MOQ)
Professional Digital Multimeter with Temperature (MS8268)
Changzhou Skyvictor Import and Export Co., Ltd.
Negotiable
50 Pieces (MOQ)
High Precision 2000 Counts Pocket Digital Multimeter (MS8233AL)
Changzhou Skyvictor Import and Export Co., Ltd.
Negotiable
50 Pieces (MOQ)
Professional 4000 Counts Digital Multimeter (MS8360F)
Changzhou Skyvictor Import and Export Co., Ltd.