Model NO.:
VS1-12/1250-25
Breaking Capacity:
High Voltage Circuit Breakers
Operation:
Manual Type
Speed:
High-Speed Circuit Breaker
Arc-extinguishing Medium:
Vacuum
Installation:
Fixed
Structure:
ACB
Poles Number:
3
Type:
Circuit Breaker
Function:
Conventional Circuit Breaker, Overcurrent Protection, OVP(Overvoltage Protection)
Certification:
VDE, ISO9001-2000, CE, CCC
Rated Voltage:
12kv
Poles:
3
Trademark:
Longxiang Electric
Transport Package:
Non-Solid Wooden Case
Specification:
IEC: M2-E2-C2
Origin:
Baoji, Shaanxi China
HS Code:
85389000
Product Description
VS1-12/630-25 Indoor Vacuum Circuit Breaker VCB with Better Price
General Description
ZN63A(VS1)-12 series of indoor vacuum circuit breaker is used for indoor 12kv switchgear, it is suitable to control and protect transmission
and distribution system such as electric network equipment and industrial&minning industry etc as their protection and control unit.
It can match with KYN28(GZS1),XGN and GG1-A series of switchgears.
The products meet standards of GB1984-2003.
This series of products include:VCB truck, isolation truck and fuse truck etc.
1.This series of VCB is used integrated design for operating mechanism and VCB body with reasonable, beautiful and compact arrangement.
2.This series of VCB adopted vertical insulation house against impact due to different weather,it can effectively prevent VIS against damage by exterior factors.
3.With two kinds of installation unit:fixed type and withdrawable type,it can meet different assembling requirements between switchgear and breaker.
Applying ambient conditions
1.Ambient temperature:-10ºC~+40ºC.
2.The height above sea level:≤1000m(besides the special requirements).
3.Relative humidity:the average humidity of a day should be no more than 95%; the average humidity of a month should be no more than 90%.
4.Saturated vapour pressure:the average pressure of a day should be no more than 2.2kPa; the average pressure of a month should be no more than 1.8kPa.
5.Earthquake intensity:not exceed 8 degrees.
6.It should be installed in the places without fire, explosion, serious filth, chemical erosion and violent vibration.
Main Technical Specification
Note:1. No.11&12 are provided when needed.
2. Switchgear should with cold wind when the rated current is 4000A.
Our Factory
Packing & Delivery
Welcome for enquiry and factory visit!
General Description
ZN63A(VS1)-12 series of indoor vacuum circuit breaker is used for indoor 12kv switchgear, it is suitable to control and protect transmission
and distribution system such as electric network equipment and industrial&minning industry etc as their protection and control unit.
It can match with KYN28(GZS1),XGN and GG1-A series of switchgears.
The products meet standards of GB1984-2003.
This series of products include:VCB truck, isolation truck and fuse truck etc.
1.This series of VCB is used integrated design for operating mechanism and VCB body with reasonable, beautiful and compact arrangement.
2.This series of VCB adopted vertical insulation house against impact due to different weather,it can effectively prevent VIS against damage by exterior factors.
3.With two kinds of installation unit:fixed type and withdrawable type,it can meet different assembling requirements between switchgear and breaker.
Applying ambient conditions
1.Ambient temperature:-10ºC~+40ºC.
2.The height above sea level:≤1000m(besides the special requirements).
3.Relative humidity:the average humidity of a day should be no more than 95%; the average humidity of a month should be no more than 90%.
4.Saturated vapour pressure:the average pressure of a day should be no more than 2.2kPa; the average pressure of a month should be no more than 1.8kPa.
5.Earthquake intensity:not exceed 8 degrees.
6.It should be installed in the places without fire, explosion, serious filth, chemical erosion and violent vibration.
Main Technical Specification
| S.N | Name | Unit | Data | |||||||
| 1 | Rated voltage | kV | 12 | |||||||
| 2 | Rated frequency | Hz | 50 | |||||||
| 3 | Rated insulation level | Rated power frequency withstand voltage | kV | 42 | ||||||
| Rated lighting impulse withstand voltage | kV | 75 | ||||||||
| 4 | Rated current | A | 630 | 1250 | 1600 | 2000 | 2500 | 3150 | 4000 | |
| 5 | Rated short circuit breaking current Rated thermal stability current (effective value) | kA | 20 | 20 | ||||||
| 25 | 25 | 25 | ||||||||
| 31.5 | 31.5 | 31.5 | 31.5 | |||||||
| 40 | 40 | 40 | 40 | 40 | 40 | |||||
| 50 | ||||||||||
| 6 | Rated short circuit making current Dynamic stability rated current | kA | 50 | 50 | ||||||
| 63 | 63 | 63 | ||||||||
| 80 | 80 | 80 | 80 | |||||||
| 100 | 100 | 100 | 100 | 100 | 100 | |||||
| 125 | ||||||||||
| 7 | Breaking operations of rated short circuit breaking current | Cycle | 50,30(above 40kA) | |||||||
| 8 | Rated short-circuit duration | s | 4 | |||||||
| 9 | Rated operating sequence | 0-0.3s-CO-180S-CO/0-180s-CO-180s-CO(above 40kA) | ||||||||
| 10 | Mechanical endurance | Cycle | 30000 | |||||||
| 11 | Rated breaking current of single capacitor bank | A | 630 | |||||||
| 12 | Rated breaking current of back to back capacitor bank | A | 400 | |||||||
| 13 | DC component | 50% | ||||||||
2. Switchgear should with cold wind when the rated current is 4000A.
Our Factory
Packing & Delivery
Welcome for enquiry and factory visit!
- Similar Products
$1500.00
1 Piece (MOQ)
7.2-12kv Indoor Vacuum Circuit Breaker Vcb Handcart Type
Shanghai Kaiji Power Equipment Co., Ltd
$4.20
240 Pieces (MOQ)
High Quality MCB 1p 2p 3p 4p D16 Mini Circuit Breaker MCB
Xiamen Ninewan Trade Co., Ltd
Negotiable
100 Pieces (MOQ)
Motor Protection Circuit Breaker Gv2-Series
Yueqing Long Road Electric Co., Ltd.