Swipe or use the arrows to view product images.
Xbd-Hy Constant Pressure Booster Fire Fighting Water Pumps
| Price | $1999.00 |
|---|---|
| Min Order | 1 Piece |
| Availability | In Stock |
| Shipping From | Shanghai, China |
| Popularity | 248 people viewed |
Model NO.:
XBD-HY
Material:
Cast Iron
Structure:
Single-stage Pump
Power:
Electric
Type:
Blade Pump
Application:
Clarified Water Pump
Industry:
Pump
Media:
Water
Performance:
Wear Pump
Theory:
Centrifugal Pump
Flow:
5-80L/S
Pressure:
0.3~2MPa
Motor Power:
3-315kw
Inlet/Outlet Caliber:
Dn50-Dn150mm
Rotating Speed:
1500-3000rpm
Trademark:
KAIYUAN
Transport Package:
Wooden Box
Specification:
ISO9001, GB6345-2006, GSG, TUV
Origin:
Shanghai
HS Code:
8413709990
Product Description
Product overview:
XBD-HY constant pressure fire pump is new, reliable, top quality special pump for firefighting, which has been developed by our technicians based on the market needs for water supply in high building fire system and living water system. Its performance, technique standards are in accordance with state standard: GB6345-2006, the performance requirements and test method of fire pump.
XBD-HY has the feature of variable flow and constant pressure. That is in the full flow range, the head has little or no variation, which can be within the rate of 5%, when pump rises from zero flow to maximum flow. And the pressure stays in normal when in zero or least flow, and the water stays constant when in maximum flow, which can improve the efficiency of the fire-distinguisher and guarantee the safety and function of the fire equipments and firefighter. Combined the characteristics of the fire pump with our technical advantages, the pump is with open-type pump impeller, less axial force, to avoid rust and stuck, cast iron pump body and cover, impeller at clients choice several materials, such as ductile cast iron, bronze, stainless steel etc.
Applications:
XBD-HY is mainly used for the water supply for fire system (fire plug distinguisher, auto spray system, and water spraying system)in industry, civil building. Besides it can be used as water supply system for fire system or living water system in building, city, mines, boiler etc.
Working conditions:
Rotating speed: 1500/3000mir
Flow range: 5-80L/S
Medium temperature: ≤ 80C (fresh water)
Head range: 0.3-2.0mpa
Model Meaning:
XB: Fire pump mark of engineering-oriented application
D: Fire pump mark of electric-driven engine
12: Fire pump mark of rated head (m)
60: Fire pump mark of rated flow (L/S)
HY: Fire pump code of constant pressure featur
XBD-HY constant pressure fire pump is new, reliable, top quality special pump for firefighting, which has been developed by our technicians based on the market needs for water supply in high building fire system and living water system. Its performance, technique standards are in accordance with state standard: GB6345-2006, the performance requirements and test method of fire pump.
XBD-HY has the feature of variable flow and constant pressure. That is in the full flow range, the head has little or no variation, which can be within the rate of 5%, when pump rises from zero flow to maximum flow. And the pressure stays in normal when in zero or least flow, and the water stays constant when in maximum flow, which can improve the efficiency of the fire-distinguisher and guarantee the safety and function of the fire equipments and firefighter. Combined the characteristics of the fire pump with our technical advantages, the pump is with open-type pump impeller, less axial force, to avoid rust and stuck, cast iron pump body and cover, impeller at clients choice several materials, such as ductile cast iron, bronze, stainless steel etc.
Applications:
XBD-HY is mainly used for the water supply for fire system (fire plug distinguisher, auto spray system, and water spraying system)in industry, civil building. Besides it can be used as water supply system for fire system or living water system in building, city, mines, boiler etc.
Working conditions:
Rotating speed: 1500/3000mir
Flow range: 5-80L/S
Medium temperature: ≤ 80C (fresh water)
Head range: 0.3-2.0mpa
Model Meaning:
XB: Fire pump mark of engineering-oriented application
D: Fire pump mark of electric-driven engine
12: Fire pump mark of rated head (m)
60: Fire pump mark of rated flow (L/S)
HY: Fire pump code of constant pressure featur
(L/S) | (m) | r/min | KW | ||||
| XBD3/5-HY | 5 | 30 | 2900 | Y100L-2 | 3 | 50 | 40 |
| XBD4/5-HY | 5 | 40 | 2900 | Y132S1-2 | 5.5 | ||
| XBD5/5-HY | 5 | 50 | 2900 | Y132S2-2 | 7.5 | ||
| XBD6/5-HY | 5 | 60 | 2900 | Y132S2-2 | 7.5 | ||
| XBD4/10-HY | 10 | 40 | 2900 | Y132S2-2 | 7.5 | 65 | 50 |
| XBD5/10-HY | 10 | 50 | 2930 | Y160M1-2 | 11 | ||
| XBD6/10-HY | 10 | 60 | 2930 | Y160M1-2 | 11 | ||
| XBD7/10-HY | 10 | 70 | 2930 | Y160M2-2 | 15 | ||
| XBD8/10-HY | 10 | 80 | 2930 | Y160L-2 | 18.5 | ||
| XBD9/10-HY | 10 | 90 | 2940 | Y180M-2 | 22 | 80 | 65 |
| XBD4/15-HY | 15 | 40 | 2930 | Y160M1-2 | 11 | ||
| XBD5/15-HY | 15 | 50 | 2930 | Y160M2-2 | 15 | ||
| XBD6/15-HY | 15 | 60 | 2940 | Y160M2-2 | 15 | ||
| XBD7/15-HY | 15 | 70 | 2940 | Y160L-2 | 18.5 | ||
| XBD8/15-HY | 15 | 80 | 2940 | Y180M-2 | 22 | ||
| XBD9/15-HY | 15 | 90 | 2950 | Y200L1-2 | 30 | ||
| XBD10/15-HY | 15 | 100 | 2950 | Y200L1-2 | 30 | ||
| XBD11/15-HY | 15 | 110 | 2950 | Y200L2-2 | 37 | ||
| XBD12/15-HY | 15 | 120 | 2970 | Y225M-2 | 45 | ||
| XBD13/15-HY | 15 | 130 | 2970 | Y225M-2 | 45 | ||
(L/S) | (m) | r/min | KW | ||||
| XBD4/20-HY | 20 | 40 | 2930 | Y160M2-2 | 15 | 80 | 65 |
| XBD5/20-HY | 20 | 50 | 2940 | Y160L-2 | 18.5 | ||
| XBD6/20-HY | 20 | 60 | 2950 | Y180M-2 | 22 | ||
| XBD7/20-HY | 20 | 70 | 2950 | Y180M-2 | 22 | ||
| XBD8/20-HY | 20 | 80 | 2950 | Y200L1-2 | 30 | ||
| XBD9/20-HY | 20 | 90 | 2950 | Y200L2-2 | 37 | ||
| XBD10/20-HY | 20 | 100 | 2950 | Y200L2-2 | 37 | ||
| XBD11/20-HY | 20 | 110 | 2950 | Y200L2-2 | 37 | ||
| XBD12/20-HY | 20 | 120 | 2970 | Y225M-2 | 45 | ||
| XBD13/20-HY | 20 | 130 | 2970 | Y225M-2 | 45 | ||
| XBD14/20-HY | 20 | 140 | 2970 | Y250M-2 | 55 | ||
| XBD15/20-HY | 20 | 150 | 2970 | Y250M-2 | 55 | ||
| XBD4/20-HY | 30 | 40 | 1480 | Y200L-4 | 30 | 100 | 80 |
| XBD5/30-HY | 30 | 50 | 1480 | Y200L-4 | 30 | ||
| XBD6/31-HY | 30 | 60 | 2950 | Y200L-2 | 37 | ||
| XBD7/32-HY | 30 | 70 | 2950 | Y200L-2 | 37 | ||
| XBD8/33-HY | 30 | 80 | 2970 | Y225M-2 | 45 | ||
| XBD9/34-HY | 30 | 90 | 2970 | Y225M-2 | 45 | ||
| XBD10/35-HY | 30 | 100 | 2970 | Y250M-2 | 55 | ||
| XBD11/36-HY | 30 | 110 | 2970 | Y250M-2 | 55 | ||
(L/S) | (m) | r/min | KW | ||||
| XBD12/30-HY | 30 | 120 | 2970 | Y280S-2 | 75 | 100 | 80 |
| XBD13/30-HY | 30 | 130 | 2970 | Y280S-2 | 75 | ||
| XBD14/30-HY | 30 | 140 | 2970 | Y280S-2 | 75 | ||
| XBD15/30-HY | 30 | 150 | 2970 | Y280S-2 | 75 | ||
| XBD16/30-HY | 30 | 160 | 2970 | Y280M-2 | 90 | ||
| XBD17/30-HY | 30 | 170 | 2970 | Y280M-2 | 90 | ||
| XBD18/30-HY | 30 | 180 | 2970 | Y280M-2 | 90 | ||
| XBD19/30-HY | 30 | 190 | 2980 | Y315S-2 | 110 | ||
| XBD20/30-HY | 30 | 200 | 2980 | Y315S-2 | 110 | ||
| XBD4/40-HY | 40 | 40 | 1480 | Y225S-4 | 37 | 125 | 100 |
| XBD5/40-HY | 40 | 50 | 1480 | Y225M-4 | 45 | ||
| XBD6/40-HY | 40 | 60 | 1480 | Y250M-4 | 55 | ||
| XBD7/40-HY | 40 | 70 | 1480 | Y250M-4 | 55 | ||
| XBD8/40-HY | 40 | 80 | 2970 | Y280S-2 | 75 | ||
| XBD9/40-HY | 40 | 90 | 2970 | Y280S-2 | 75 | ||
| XBD10/40-HY | 40 | 100 | 2970 | Y280S-2 | 75 | ||
| XBD11/40-HY | 40 | 110 | 2970 | Y280M-2 | 90 | ||
| XBD12/40-HY | 40 | 120 | 2970 | Y280M-2 | 90 | ||
| XBD13/40-HY | 40 | 130 | 2970 | Y280M-2 | 90 | ||
| XBD14/40-HY | 40 | 140 | 2970 | Y280M-2 | 90 | ||
| XBD15/40-HY | 40 | 150 | 2980 | Y315S-2 | 110 | ||
| XBD16/40-HY | 40 | 160 | 2980 | Y315S-2 | 110 | ||
| XBD17/40-HY | 40 | 170 | 2980 | Y315S-2 | 110 | ||
| XBD18/40-HY | 40 | 180 | 2980 | Y315M-2 | 132 | ||
| XBD19/40-HY | 40 | 190 | 2980 | Y315M-2 | 132 | ||
| XBD20/40-HY | 40 | 200 | 2980 | Y315L1-2 | 160 | ||
| XBD4/50-HY | 50 | 40 | 1480 | Y225M-4 | 45 | 125 | 100 |
| XBD5/50-HY | 50 | 50 | 1480 | Y225M-4 | 45 | ||
| XBD6/50-HY | 50 | 60 | 1480 | Y225M-4 | 55 | ||
| XBD7/50-HY | 50 | 70 | 1480 | Y225M-4 | 55 | ||
| XBD8/50-HY | 50 | 80 | 1480 | Y280S-4 | 75 | ||
| XBD9/50-HY | 50 | 90 | 2970 | Y280S-2 | 75 | ||
| XBD10/50-HY | 50 | 100 | 2970 | Y280M-2 | 90 | ||
| XBD11/50-HY | 50 | 110 | 2980 | Y315S-2 | 110 | ||
| XBD12/50-HY | 50 | 120 | 2980 | Y315S-2 | 110 | ||
| XBD13/50-HY | 50 | 130 | 2980 | Y315S-2 | 110 | ||
| XBD14/50-HY | 50 | 140 | 2980 | Y315M-2 | 132 | ||
| XBD15/50-HY | 50 | 150 | 2980 | Y315M-2 | 132 | ||
| XBD16/50-HY | 50 | 160 | 2980 | Y315L1-2 | 160 | ||
| XBD17/50-HY | 50 | 170 | 2980 | Y315L1-2 | 160 | ||
| XBD18/50-HY | 50 | 180 | 2980 | Y315L1-2 | 160 | ||
| XBD19/50-HY | 50 | 190 | 2980 | Y315L2-2 | 200 | ||
| XBD20/50-HY | 50 | 200 | 2980 | Y315L2-2 | 200 | ||
| XBD4/60-HY | 60 | 40 | 1480 | Y225M-4 | 45 | 150 | 125 |
| XBD5/60-HY | 60 | 50 | 1480 | Y225M-4 | 45 | ||
| XBD6/60-HY | 60 | 60 | 1480 | Y225M-4 | 55 | ||
| XBD7/60-HY | 60 | 70 | 1480 | Y280S-4 | 75 | ||
(L/S) | (m) | r/min | KW | ||||
| XBD8/60-HY | 60 | 80 | 1480 | Y280S-4 | 75 | 150 | 125 |
| XBD9/60-HY | 60 | 90 | 1480 | Y280M-4 | 90 | ||
| XBD10/60-HY | 60 | 100 | 2980 | Y315S-2 | 110 | ||
| XBD11/60-HY | 60 | 110 | 2980 | Y315S-2 | 110 | ||
| XBD12/60-HY | 60 | 120 | 2980 | Y315S-2 | 110 | ||
| XBD13/60-HY | 60 | 130 | 2980 | Y315M-2 | 132 | ||
| XBD14/60-HY | 60 | 140 | 2980 | Y315L1-2 | 160 | ||
| XBD15/60-HY | 60 | 150 | 2980 | Y315L2-2 | 160 | ||
| XBD16/60-HY | 60 | 160 | 2980 | Y315L2-2 | 200 | ||
| XBD17/60-HY | 60 | 170 | 2980 | Y315L2-2 | 200 | ||
| XBD18/60-HY | 60 | 180 | 2980 | Y315L2-2 | 200 | ||
| XBD19/60-HY | 60 | 190 | 2980 | Y355M-2 | 250 | ||
| XBD20/60-HY | 60 | 200 | 2980 | Y355L1-2 | 280 | ||
| XBD4/70-HY | 70 | 40 | 1480 | Y250M-4 | 55 | 150 | 125 |
| XBD5/70-HY | 70 | 50 | 1480 | Y250M-4 | 55 | ||
| XBD6/70-HY | 70 | 60 | 1480 | Y280S-4 | 75 | ||
| XBD7/70-HY | 70 | 70 | 1480 | Y280M-4 | 90 | ||
| XBD8/70-HY | 70 | 80 | 1480 | Y280M-4 | 90 | ||
| XBD9/70-HY | 70 | 90 | 1490 | Y315S-4 | 110 | ||
| XBD10/70-HY | 70 | 100 | 1490 | Y315S-4 | 110 | ||
| XBD11/70-HY | 70 | 110 | 2980 | Y315S-2 | 110 | ||
| XBD12/70-HY | 70 | 120 | 2980 | Y315M-2 | 132 | ||
| XBD13/70-HY | 70 | 130 | 2980 | Y315M-2 | 132 | ||
| XBD14/70-HY | 70 | 140 | 2980 | Y315M-2 | 160 | ||
| XBD15/70-HY | 70 | 150 | 2980 | Y315L1-2 | 160 | ||
| XBD16/70-HY | 70 | 160 | 2980 | Y315L1-2 | 200 | ||
| XBD17/70-HY | 70 | 170 | 2980 | Y315L2-2 | 200 | ||
| XBD18/70-HY | 70 | 180 | 2980 | Y315L2-2 | 250 | ||
| XBD19/70-HY | 70 | 190 | 2980 | Y355M-2 | 250 | ||
| XBD20/70-HY | 70 | 200 | 2980 | Y355M-2 | 280 | ||
| XBD4/80-HY | 80 | 40 | 1480 | Y355L-2 | 55 | 150 | 125 |
| XBD5/80-HY | 80 | 50 | 1480 | Y250M-4 | 75 | ||
| XBD6/80-HY | 80 | 60 | 1480 | Y280S-4 | 90 | ||
| XBD7/80-HY | 80 | 70 | 1480 | Y280M-4 | 90 | ||
| XBD8/80-HY | 80 | 80 | 1490 | Y280M-4 | 110 | ||
| XBD9/80-HY | 80 | 90 | 1490 | Y315S-4 | 132 | ||
| XBD10/80-HY | 80 | 100 | 1490 | Y315M-4 | 132 | ||
| XBD11/80-HY | 80 | 110 | 1490 | Y315M-4 | 160 | ||
| XBD12/80-HY | 80 | 120 | 1490 | Y315L1-4 | 160 | ||
| XBD13/80-HY | 80 | 130 | 2980 | Y315L1-4 | 200 | ||
| XBD14/80-HY | 80 | 140 | 2980 | Y315L2-2 | 200 | ||
| XBD15/80-HY | 80 | 150 | 2980 | Y315L2-2 | 250 | ||
| XBD16/80-HY | 80 | 160 | 2980 | Y355M-2 | 250 | ||
| XBD17/80-HY | 80 | 170 | 2980 | Y355M-2 | 280 | ||
| XBD18/80-HY | 80 | 180 | 2980 | Y355M-2 | 280 | ||
| XBD19/80-HY | 80 | 190 | 2980 | Y355L-2 | 315 | ||
| XBD20/80-HY | 80 | 200 | 2980 | Y355L-2 | 315 |