Ysav-R80V Vet Medical Equipment Veterinary Anesthesia Ventilator
| Price | Negotiable |
|---|---|
| Min Order | 1 Set |
| Availability | In Stock |
| Shipping From | Guangdong, China |
| Popularity | 542 people viewed |
Model NO.:
YSAV-R80V
out Looking:
Portable
with Ventilator:
Yes
Certificate:
CE, ISO
Scope of Application:
Animal
O2 Sensor Failure:
Fio2 <15% Vol
Silent Alarm:
≤ 120 S
Brand:
Yueshen
Operating Mode:
Vcv, Pcv, Spont, Manual, Demo
Battery Type:
Li-ion, Work Time More Than 2 Hours
Trademark:
YSENMED
Transport Package:
Wooden Case
Specification:
CE certificate
Origin:
China
HS Code:
9018909000
Product Description
YSAV-R80V Veterinary Anesthesia Ventilator
Feature:
Specially user for animal,anesthesia ventilator,could widely apply in vet hospital,animal R&D institute,university laboratory,animal clinic,animal zoo,etc,it can match any brand anesthesia machine to use
- Compact and salve the space.
- Light and easy to move,save animal hospital cost.
- automatically Calculation by weight to the other parameter
- With breathing mode PCV mode, achieve the breathing automatically,
- Assure the animal more comfortable.
- With big animal bellow and small animal bellow,specially for animal use
- The gas source pipeline take the high precious gas source,no leakage forever.
- HD TFT Touch screen,perfect technology,touch at key to Set parameter ,very easy and simple to operate.
- Build in battery could continue two more hours in case of power failure
- Matching with different brand veterinary anesthesia machine
Specification
| Basic description | ||
| Parameter | Description | |
| Display | 9 inch TFT, with touch screen. | |
| Drive gas | Gas type | O2 or Air |
| Inlet pressure | 280-600 kPa. | |
| Max flow | ≤ 120 L / min. | |
| Operating Mode | VCV,PCV,SPONT,Manual,Demo | |
| Waveform | Waveform: Pressure,Flow-rate,Volume Loop:PV loop, PF loop,FV loop | |
| Safety Pressure | System pressure does not exceed 6 KPa. | |
| Battery Type | Li-ion,work time more than 2 hours | |
| Parameters setting range | |
| Parameter | description |
| Tidal volume | Range: 20 - 1500ml; Increment: 1 mL; |
| Respiratory rate | Range: 1 ~ 100 bpm; |
| Inspiratory time | Range: 0.1 ~ 10.0 s |
| Respiratory ratio | Range: 9.9:1 to 1:9.9 |
| Percentage of inspiratory pause | Range: 0 to 50% |
| PEEP | Range: OFF, 3 ~ 20 cmH2O |
| Pressure Support | Range: 0 ~ 60 cmH2O |
| Pressure Control | Range: 5 ~ 60 cmH2O |
| Flow trigger | Range: 0.5 ~ 20L/min |
| Pressure Trigger | Range: -1 ~ -20 cmH2O |
| PSV Insp Termination Level | 25%. |
| Monitored parameters | |
| Parameter | Description |
| Inspiratory tidal volume | Range: 0 ~ 2500 mL |
| Expiratory tidal volume | Range: 0 ~ 2500 mL |
| Minute ventilation | Range: 0 ~ 60 L / min |
| Spontaneous minute ventilation | Range: 0 ~ 60 L / min |
| Respiratory rate | Range: 0 ~ 100 bpm |
| Spontaneous breathing frequency | Range: 0 ~ 100 bpm |
| Respiratory ratio | Range: 9.9:1 to 1:9.9 |
| Peak airway pressure | Range: 0 ~ 100 cmH2O |
| Mean airway pressure | Range: 0 ~ 100 cmH2O |
| PEEP | Range: 0 ~ 100 cmH2O |
| Inspiratory plateau pressure | Range: 0 ~ 100 cmH2O |
| FiO2(optional) | Range: 15 to 100% |
| Alarm settings | ||
| Alarm type | Range | |
| Tidal volume | High | 0 ~ 2000 mL, OFF |
| Low | 0 ~ 1500 mL | |
| Minute ventilation | High | 1 ~ 99 L |
| Low | 0 ~ 98 L | |
| Respiratory rate | High | 1 ~ 100bpm |
| Low | 0 ~ 99 bpm | |
| FiO2(optional) | High | 19 ~ 100% |
| Low | 18 ~ 99% | |
| Airway pressure | High | 6 ~ 99 cmH2O |
| Low | 0 ~ 9 8 cmH2O | |
| FiCO2 (optional) | High | 0.1 to 13.3%; |
| Low | 0 to 13.2% | |
| Continuous Positive Airway Pressure | Airway pressure greater than (PEEP +15) cmH2O, 15 s sustained when an alarm is triggered. | |
| Negative pressure alarm | Airway pressure is less than (-10) cmH 2 O. | |
| Apnea alarm | Setting time is 10 ~ 60 s, in increments of 1 s. | |
| Gas deficiency alarm | Gas pressure is less than 280 kPa. | |
| AC power failure alarm | The mains breaks down or the power cord disconnects | |
| Low battery alarm | Alarm battery time is 20 min. | |
| Alarm battery is exhausted | Alarm battery time is 10 min. | |
| Silent Alarm | ≤ 120 s | |
| O2 sensor failure | FIO2 <15% Vol; | |
We are a company aiming to make one stop shopping for our customers. We equiped hospital
operation room with many kind of items like operation table, orthopedic drill and saw, ECG,
defibrillator etc.
We listed some hospital operation room items basic items for your reference as below:
| operation room | anesthesia machine |
| ventilator | |
| operating lamp | |
| operation table | |
| Pendant | |
| medical drill and saw | |
| ECG | |
| patient monitor | |
| Defibrillator | |
| infusion pump | |
| Electrocoagulation | |
| oxygen generator | |
| electric suction device | |
| autoclave sterilizer |