Model NO.:
ZJ-10Q/275 (KYN1)
Application:
High-voltage
Material:
Epoxy Resin
Structure:
Post Insulator
Type:
Insulator
Usage:
High Voltage Power Transmission, Insulation
Connection Method:
Trough Type
Certification:
ISO9001
Color:
Black
Brand:
Talent
Trademark:
Talent
Transport Package:
Carton
Origin:
China
HS Code:
854710000
Product Description
ZJ-10Q/275 Insulator (Dimension: Φ145*130)
General description
1.This insulator is formed by epoxy with APG technies,it is used for insulation isolation and connection transition of overhead transmission line.
2. Altitude:≤1000m
3. Ambient temperature:+40ºC~10ºC
4. The relative humidity shall not be more than 95% at+20ºC ambient temperature.
5. NO gas ,wapor or dust that may severely affect the insulation of contact box,no explosive or corrosive substance.
6. The coper contact to earth shall withstand power frequency test voltage(effective value )of 42kv for 5 minutes and lightning impulse vpltage (peak value)of 75KV.
7. The temperature of lead-out terminal shall not bemore than 65ºC if the contact box is used for long time in rated current condition.
8. See the attached figure for the outline and installation dimension of insulator.
General description
1.This insulator is formed by epoxy with APG technies,it is used for insulation isolation and connection transition of overhead transmission line.
2. Altitude:≤1000m
3. Ambient temperature:+40ºC~10ºC
4. The relative humidity shall not be more than 95% at+20ºC ambient temperature.
5. NO gas ,wapor or dust that may severely affect the insulation of contact box,no explosive or corrosive substance.
6. The coper contact to earth shall withstand power frequency test voltage(effective value )of 42kv for 5 minutes and lightning impulse vpltage (peak value)of 75KV.
7. The temperature of lead-out terminal shall not bemore than 65ºC if the contact box is used for long time in rated current condition.
8. See the attached figure for the outline and installation dimension of insulator.
- Similar Products
$1000.00
1 Piece (MOQ)
123kv 3150A ANSI/IEEE Gis Transformer Bushing
Dalian Electric International Co., Ltd
$10.00
50 Pieces (MOQ)
33kv 8kN Composite & Polymer Pin Insulator Fpq-33/8
Dalian Electric International Co., Ltd
$30.00
50 Pieces (MOQ)
Polymer Line Post Insulator for Transmission
DALIAN HIVOLT POWER SYSTEM CO., LTD.