Menu
Global B2B sourcing platform
Verified suppliers and manufacturers

ZW32-12 Outdoor Vacuum Circuit Breaker with ISO9001-2000//Recloser

Price $2000.00
Min Order 1 Set
Availability In Stock
Shipping From Shaanxi, China
Popularity 449 people viewed
Model NO.:
ZW32-12
Breaking Capacity:
High Voltage Circuit Breakers
Operation:
Electric Type
Speed:
Normal Type Circuit Breaker
Arc-extinguishing Medium:
Oil-immersed Type
Installation:
Fixed
Structure:
MCCB
Poles Number:
3
Type:
Circuit Breaker
Function:
Conventional Circuit Breaker, Overcurrent Protection, OVP(Overvoltage Protection)
Certification:
ISO9001-2000, CE, CCC
Rated Voltage:
12kv
Phase:
Three-Phase AC
Rated Frequency:
50(60)Hz
Rated Current:
630A
with CT:
Yes / 3
Weight:
About 100kg
Trademark:
Longxiang Electric
Transport Package:
Non-Solid Wooden Case
Specification:
IEC: M2-E2-C2
Origin:
Baoji, Shaanxi China
HS Code:
85389000
Product Description
ZW32-12 Type Outdoor HV Vacuum Circuit Breaker      
             

General Description
ZW32-12type outdoor high voltage vacuum circuit breaker is three-phase AC, 50(60)Hz outdoor power distribution equipment with the rated 
voltage of 12kV. It is mainly used to break and close the load current, over load current, and short circuit current in the electric power system.

It fits to be used to protect and control the circuit in substation, mining and industrial enterprises. It also can be used in the frequently operation places such as the rural power network.
The product is accordance with GB1984-2003 standard.

The ZW32-12G VCB-Isolating switch combination consists of Vacuum circuit breaker body and isolating switch.

Applying ambient conditions
1.Ambient temperature:-30~+40;
2.The height above sea level:<1000m;(besides the special requirements)
3.Relative humidity:the average humidity of a day should be no more than 95%; the average humidity of a month should be no more than 90%.
4.Saturated vapor pressure:the average pressure of a day should be no more than 2.2kPa; the average pressure of a month should be no more than 1.8kPa.
5.Earthquake intensity:not exceed 8degrees.
6.Wind pressure should be no more than 700pa(it is equivalent to wind speed of 34m/s).
7.The air filthy should be within III degrees.
8.It should be used in the places without fire, explosion, serious filth, chemical erosion and violent vibration.              
                                                                                                              




   



Welcome for enquiry and factory visit!  
  • Similar Products