Specification:
| Item | S1100VG | |
| Basic function | Maximum frequency | 400H |
| Input frequency | Digital setting: 0.01Hz | |
| resolution | Analog setting: maximum frequency ×0.1% | |
| Control mode | V/F control | |
| Vector flux control 1 | ||
| Vector flux control 2 | ||
| Startup torque | G modle: 0.5Hz/180%(Open loop Vector flux control) | |
| P model: 0.5Hz/120%(Open loop Vector flux control) | ||
| Speed adjustment | 1:200(Open loop Vector flux control) | |
| range | ||
| Speed stabilization | Open loop Vector flux control:≤±0.5% | |
| precision | ||
| Speed stabilization | Open loop Vector flux control:≤±0.3% | |
| precision | ||
| Torque response | ≤40ms(Open magnetic flux vector control) | |
| Overload capacity | G model: 150% rated current 60s; 180% rated current 3s | |
| P model: 130% rated current 60s; 150% rated current 3s | ||
| Torque hoist | Automatic torque hoist; manual torque hoist 0.1% to | |
| 30.00% | ||
| V/F curve | Linear V/F, Multi-point V/F, and Square V/F | |
| Speed-up and | Straight line or S curve speed-up and speed-down | |
| Speed-down curve | mode;Two kinds of speed-up and speed-down | |
| time;Speed-up and speed-down time ranges between 0.0s | ||
| to 3000.0min. | ||
| DC brake | DC brake frequency:0.00Hz to maximum frequency; brake time:0.0s to 36.0s,and brake current value: 0.0% to 100.0%. | |
| Jog control | Jog frequency range:0.00Hz to 50.00Hz;jog | |
| speed-up/speed-down time: 0.0s to 3000.0s. | ||
| Simple PLC and MS speed running | It can realize a maximum of 16 segments speed running | |
| via the built-in PLC or control terminal. | ||
| Built-in PID | It is easy to realize process-controlled close loop control | |
| system. | ||
| (AVR)Auto | It can keep constant output voltage automatically in case of change of mains voltage. | |
| voltage regulation | ||
| Torque limit and control | "Shovel" characteristics, the runtime automatic torquelimit, prevent frequent over-current trip; closed loop vectormodel can realize the torque control | |
| Individua-lized function | Peripherals self-detection upon | It can conduct safety detections on the peripherals upon power-on, including earth and short circuit detections. |
| power-on | ||
| Shared DC bus | It can realize the function that multiple inverters share the DC bus. | |
| function | ||
| JOG key | Programmable key: Select the command channel switching/forward and reverse rotations/jog operation. | |
| Display | LED display | The machine has the LED keyboard,and realize parameter settings,status monitoring function. |
| and | ||
| Keyboard | LCD display | Optional, / English prompts content |
| Operation | Parameter Copy | Keyboard can be copied using the parameters to achive the rapid replication parameter. |