| Items | Data |
| Biogas genset | |
| Brand | Yuchai |
| Genset Model | AYG1000 |
| Structure Form | Separate type |
| Rated Power ( kW/kVA ) | 1000/1250 |
| Continuous power ( kW ) | 800 |
| Rated Current ( A ) | 1640 |
| Rated Voltage ( kV ) | 440/240 |
| Rated Frequency ( Hz ) | 60 |
| Rated Power Factor | 0.8(LAG) |
| Noise ( dB ( A ) ) | < 102 |
| Exhaust Emission Targets | Meet the standard GB/T 22343-2008 oil industry uses biogas internal combustion generator. |
| Rated Condition Max. Gas Consumption ( m3/h based on 21.6M/Nm3 ) | 427 |
| Fuel Consumption Rated ( Nm3/kW.h ) | 0.36 |
| Genset Dimensions ( L×W×H ) ( mm ) | 5380×1650×2426 |
| Gneset Net Weight ( kg ) | 14000 |
| Output Power Dynamic Performance Index | |
| No-load Voltage Setting Range | 95% - 105% |
| Steady-state Voltage Regulation | ≤ ±1% |
| Transient Voltage Regulation | ≤ -15% - +20% |
| Voltage Recovery Time | ≤ 3s |
| Voltage Fluctuation Rate | ≤ ±0.5% |
| Transient Frequency Adjustment Rate | ≤ ±10% |
| Frequency Stabilization Time | ≤ 5s |
| Line Voltage Waveform Sinusoidal Distortion Rate | ≤ 2.5% |
| Biogas Engine | |
| Brand | Austria AVL tech Yuchai engine |
| Structure Type | V type, water cooled, 4 stroke, turbocharge, inter-cooling |
| Model | NY792D120TL |
| Cylinder No. Bore * Stroke - Displacement | V12-200×210-79.2 |
| Rated Power ( kW ) | 1100 |
| Rated Speed ( r/min ) | 1500 |
| Speed Type | American woodward integrated electronic throttle automatic speed adjustment |
| Combustion & Ignition Mode | American woodward electric control rarefied combustion |
| Gas Intake Method | Water cooled exhaust gas turbocharged, inter-cooling |
| Starting Method | 24VDC |
| Overhaul Period ( h ) | ≥30000 |
| Brush-less Alternator | |
| Brand / Model | Xingnuo/XN6G |
| Structure Form | Single bearing, brush-less / with automatic |
| Rated Capacity ( kW/kVA ) | 1000/1250 |
| Rated Voltage ( kV ) | 400/230 |
| Rated Current ( A ) | 1800 |
| Rated Frequency ( Hz ) | 50 |
| Power Factor | 0.8(LAG) |
| Connecting Wire Method | 3 phase 4 wires |
| Insulation Class | H |
| Protection Class | IP23 |
| Gneset Management & Control System | |
| Operation Mode | Automatic / Manual |
| Engine Control System | American Woodward |
| Genset Control System | Comap |
| Genset Operation Date Display | Large screen liquid crystal display |
| Digital Government System | American Woodward |
| Automatic Fuel Regulation & Control System | |
| Natural Gas Quality | Meet the II class biogas requirements of GB 17820-2012 bioGas |
| Natural Gas Flow Control | Automatic adjustment of fuel control valve |
| Gas Mixer | Venturi Mixer |
| Gas pressure Regulator | Italy Fiorentini Minireg diaphragm type gas pressure regulator |
| Fuel Control Method | Close loop control, lean burn |
| Gas Maximum Inlet Pressure | <50kPa |
| Gas Minimum Inlet Pressure | ≥5kPa |
| Maximum Fuel Gas Temperature | ≤40ºC |











Audited Supplier