Drop-out Fuse Cutout (RW12-33)

Price $50.00 Compare
Min Order 5 Pieces
Availability In Stock
Shipping From Zhejiang, China
Popularity 441 people viewed
Quantity
+-
 

Xiya Electric Equipment Co., Ltd.

VIP   Audited Supplier 13 years
Profile Certified by SGS/BV
RW12-33
High
Current Fuse
High Voltage
XIKAI
CE CCC
Zhejiang China
Product Description
General

Drop-out Fuse Cutout and pull the load drop-out fuse is outdoor high-voltage protection of electrical. It is installed in high-voltage side of the distribution transformer or the Support Link of the distribution line as Transformers and lines short circuit, overload protection, and open, co-load current. Drop-out fuse is made by the insulating bracket and fuse tubes, static contact is installed at both ends of the insulation bracket, Moving contact installed on both ends of fuse tube, Fuse tube is composed by inner arc tube and outer phenolic paper tube or epoxy glass cloth tube. Pull load drop-out fuse can enhance flexibility auxiliary contacts and arc chute for open, co-load current.

When Drop-out Fuse Cutout in the normal operation, the fuse tube with fuse tension to form the closed position. When the system fails, the fault current blown fuse quickly, And form of arc, arc tube by the electric arc burning, Decompose large amounts of gas, formed a high pressure in the tube, and formed vertical wind along the pipeline, The arc was quickly stretch and elongated. After fuse blows, the moving contact lose tension and turned out, locking mechanism, release fuse tube, fuse tube drop, formed breaking Position. When pull the load, use insulating rod to pull the moving contact. At this point, the moving and the static contact is still contact. Continued pull the contact with the insulating rod, the auxiliary contacts are separated. The arc appear between the auxiliary contacts, and was stretch in the hood slit, the arc cover has gas, when the current is 0, the arc goes out.

Use and Standards

This product is used in 10 ~ 35KV distribution lines branching lines and distribution transformers primary side, For overload and short circuit protection Separation and Combination the rated load current.

The product model by JB/T8321-1996Method of type AC high-voltage fuses prepared. Product parameters made by GB15166.3-1994 high voltage fuses Expulsion fusesstandards. The standards are not clearly defined the important parameters and configuration, According to JB/DQ2139-198610 ~ 35KV outdoor high voltage drop fuse interim technology requires correction.

Conditions of Use

Ambient temperature: Not higher than +40 degree, not less than -30 degree

Altitude: Not exceed 1000m (1000m above can be corrected GB311.1-1997)

Power frequency: 50 ± 2Hz

Earthquake intensity: 7 degrees below

Maximum wind speed: 35m/s

Technical Parameters

33KV-35KV
  • Contact Supplier
Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA  
$1.00 1 Piece(MOQ)

Surge Protector Device

Xiya Electric Equipment Co., Ltd.
$1.00 1 Piece(MOQ)

Metal Oxide Arrester

Xiya Electric Equipment Co., Ltd.
$5000.00 5 pieces(MOQ)

Gw23-252D Outdoor AC High Voltage Fuse Switch Disconnector

Xiya Electric Equipment Co., Ltd.
$1.00 1 Piece(MOQ)

Line Post Insulator

Xiya Electric Equipment Co., Ltd.
$12.00 2 Pieces(MOQ)

12kv High Voltage Disconnect Switch for Distribution Line

Zhejiang Haivo Electrical Co., Ltd.
$1000.00 1 Piece(MOQ)

Full Range of Original Bussmann European Standard Square Fuses

Jiangsu Core Drill Age Electronic Technology Co., Ltd
$47.15 1 Set(MOQ)

Xrnm 6kv 12kv 50ka Best Selling High Voltage Current Limiting Fuses for Motor Protection British BS Standards

ZHEJIANG KANGCHUANG ELECTRIC CO.,LTD
$0.90 500 Pieces(MOQ)

0308f Serise Fast-Acting Surface Mount Ceramic Tube Fuse

DELIN COMM LIMITED
$5.00 500 Pieces(MOQ)

Medium Auto Fuse 20A58V UL248 RMS-Atc-Nl/PC-20A (Manufacturer with IATF16949 certified)

Reomax Electronics Co., Ltd.
$9.80 60 Pieces(MOQ)

Reliable 500V 160A Nt00-3p Fuse Holder Surge Protector for Safety

Zhejiang Leiertai Lightning Protection Technology Co., Ltd.