Small size,high accuracy,good consistency,for voltage and power measurement

Front view Bottom view
Model | ZMPT107-1 |
Rated input current | 2mA |
Rated output current | 2mA |
Turns ratio | 1000:1000 |
Phase angle error | ≤45'(input 2mA,sampling resistor 50Ω) |
Linear range | 0~1000V 0~10mA(sampling resistor 50Ω) |
Linearity | ≤ 0.2%(20% dot~120%dot) |
Permissible error | -0.6% ≤ f ≤0%(input 2mA,sampling resistor 50Ω) |
Isolation voltage | 3000V(AC) |
Application | voltage and power measurement |
Encapsulation | Epoxy |
Installation | PCB mounting(Pin Length>3mm) |
Operating temperature | -40ºC~+85ºC(PBT shell) |
Shell Material | PBT (Note: PBT shell is available for wave soldering) |

Figure I Figure II
2. The product can be directly through the resistance sampling , easy to use ( Figure II).