3p. 4p 200A to 6300A High Quality Air Circuit Breaker

Price Negotiable Compare
Min Order 200 Pieces
Availability In Stock
Shipping From Zhejiang, China
Popularity 320 people viewed
Quantity
+-
 

Yueqing Long Road Electric Co., Ltd.

VIP   Audited Supplier 18 years
Profile Certified by SGS/BV
SRW1
Low Voltage Circuit Breakers
Electric Type
High-Speed Circuit Breaker
Air
200A to 6300A,
415V 690V
3p.4p
20,10,10
Long Road/OEM
Carton
China
Product Description

1. Product Introduction:
With a rated current from 200A to 6300A, and rated operational voltage 415V 690V, 50Hz, the NA8G series air circuit breaker (hereinafter referred to as "breaker") is mainly used in the distribution network to distribute electric energy and protect lines and power equipment from being damaged by overload, under voltage, short circuit, single-phase grounding and other failures.
Having art-oriented appearance, high breaking capacity, zero arcover and vanities of intellectualized protection functions, that breaker can be used for selective protection with accurate action, no unnecessary power cut, and better power supply reliability.
The product allows the wire to enter or enter from the lower port, and the open frame (draw-out) circuit breaker has isolation function.
That breaker can be widely used for power stations, factories, mines and modern tall buildings, especially the distribution system in the intelligent building, and also widely used in green projects such as wind and solar power generation.
This product meets the requirements in IEC/EN 60947-2

2.Operation conditions
2..1 When theambientair temperature is-5C - +40 C, the mean value is no greater than +35C within 24 hours.
Note: Ifthe upper limit is higherthan +40C or lower limit lower than -5C in work, discussions shall be made between the user and the manufacture
2.2 Altitude: not higher than 2000m for the installation site.
2.3 When the ambient air temperature is +40C, the relative humidity of the air shall not be higher than 50%;a higher relative humidity is allowed at a lower temperature; for example, forthe wettest month, the maximum relative humidity averaged shall be 90% while the lowest temperature averaged in that month + 20C , and special measures shall betakenforthecondensation occasionally produced due to temperature change.
2.4 Class of pollution: 3
2.5
 The installation category of the breaker' main circuit is IV; when the rated operational voltage of the main circuit is less than or equal to AC400V, The installation category of the control circuit and auxiliary circuit is III, apart from the similarity between the under voltage release coil and the intellectual controller's power transformer primary coil and the breaker;When the rated operational voltage of the major loop is greater than AC400V and less than or equal to AC690V, it is necessary for the control circuit and auxiliary circuit to be isolated from the major loop, and the highest operational voltage of the control circuit and auxiliary circuit is AC400V, the installation category of the control circuit and auxiliary circuit being III.
3. Main technical parameters
Shell grade rated currentInm A160032006300
Rated current In A 200,400,630,800,
1000,1250,1600
1600,2000,2500,
2900,3200
4000,50006300
Nominal insulation voltage UiV69010001000 
Rated operational voltage UeV415 690415 690415 
Rated ultimate short circuit breaking capacity leu kA50 25100 65120 
Rated service short circuit breaking capacity les kA40 2080 65100 
Rated short time withstand current lcw,1s kA40 2080 65100 
Number of poles 3P 4P3P 4P3P 4P3P
Frequency of operation (number of times/h)201010 
 Mechanical life300030002000 
Number of operationsElectrical Life10001000500 
Flashover distance mm 000 
Line incoming pattern Wire to enter from the upper or lower portWire to enter from the upper or lower portWire to enter from the upper or lower port 
 fixed type kg22/26.552.5/66.5- 
Net weight (3 poles/4 poles)draw-out type kg42.5/5598/121210/233233
Size(3 poles/4 poles)fixed type320x(254/324)x258406x(422/537)x329- 
Height x width x depthdraw-out type351 x(282/352)x352439x(435/550)x445439x(835/928)x501439x928x501
Detailed Photos

 

  • Contact Supplier
Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA  
Negotiable 100 Pieces(MOQ)

Bzmj Series Self-Healing Low-Voltage Shunt Capacitor

Yueqing Long Road Electric Co., Ltd.
$8.15 500 Pieces(MOQ)

Electronic Motor Over Current Protector

Yueqing Long Road Electric Co., Ltd.
$1.10 1000 Pieces(MOQ)

230/400v Ac Mini Circuit Breaker

Yueqing Long Road Electric Co., Ltd.
$23.63 20 Pieces(MOQ)

Made in China CE Certificate B Type 32A 63A 100A ELCB RCD RCBO Residual Current Circuit Breaker

Yueqing Long Road Electric Co., Ltd.
$0.85 12 Pieces(MOQ)

Chint Nxb-63 MCB 1p 2p 3p 4p C1 C2 C3 C4 C6 C10 C16 C20 C25 C32 C40 C50 C63 B1 B2 B3 B4 B6 B10 B16 B20 B25 B32 B40 B50 B63 Chnt Mini Circuit Breaker

Anshan Fenghui Continuous Caster Manufacture Co., Ltd.
$1.61 1 Box(MOQ)

Circuit Breaker Wsb1-125 Miniature Moulded Case Air AC 27mm Width Breaking Capacity 6ka 10ka Vacuum Electrical Switch Miniature Circuit Breaker

Zhejiang Westhomes Electric Co., Ltd.
$1000.00 1 Piece(MOQ)

New and Original a-Bb S204m-C40 Miniature Circuit Breaker - 4p - C - 40 a 2CDS274001r0404

Shenzhen Aimiqu Technology Co., Ltd.
$48.86 120 Pieces(MOQ)

Breaker 6-40A AFCI Arc Fault Interrupters AfCI Breaker

Taimu Electrical (Hangzhou)Co., Ltd.
$7.00 12 Pieces(MOQ)

Ewelink Tuya Zigbee WiFi Smart Energy Meter Voltage Current Protector Circuit Breaker

Zhejiang Shanmeng Electric Co., Ltd.
$230.00 1 Piece(MOQ)

Air Conditioner Overvoltage and Underoltage Smart Auto Recloser 3p 4p MCCB Circuit Breaker

Yuming Electric Co., Ltd