| Model:HYLV-100-C |
| Specification |
| Items | Parameters | Remark |
| Rated Voltage | 51.2V | |
| Rated Cpacity | 5.12kWh | |
| Rated Power | 5000W | |
| Life Cycles | ≥4000 Times @1C/25ºC | |
| Life Span | 10 Years | |
| Efficiency | 93% | |
| Charge cut-off voltage | 58.4V | |
| Discharge cut-off voltage | 44.8V | After 30S of over-discharge protection, it still can't be recovered, it will enter the low power consumption mode |
| Continuous charging and discharging current | 1C/100A | |
| Charge overcurrent protection | 110A | 10 consecutive occurrences will be locked and no longer automatically released |
| Discharge overcurrent protection | 110A | 10 consecutive occurrences will be locked and no longer automatically released |
| Equalisation Function | Passive Equilibrium | Open differential pressure 30mA |
| Protection function | Over- and under-voltage of the system as a whole, over- and under-voltage of a single unit, over-current of charging and discharging, high and low temperature of charging, high and low temperature of discharging, short-circuit protection, and insulation failure protection. | |
| Charging operating temperature | 0ºC~55ºC | Optimum working temperature: 15ºC~35ºC |
| Discharge operating temperature | -20ºC~55ºC |
| Storage temperature | 0ºC~35ºC | With one Year |
| Allowable relative humidity | 10%~95% Non-Condensing | |
| SOC Estimate | ≤5% | |
| Self-Discharge | Every Month≤3% | |
| Communication Method | CAN/RS485 | |