Radiator | module | display panel | copper bar | communication | packing | Coil transformer LOGO |
300*200*65 | MTC300A/1600V | Full series unification | 7000series 75~110KW (thin) | Profibus/RS485 | 274*160*408 mm | Recci |

18 MOTOR PROTECT FUNCTIONS | Suitable for all kinds of bad environments |
1.Start overload protection | 2.Running overload protection |
3.Starting overcurrent protection | 4.Running over current proterction |
5. Overvoltage protection | 6.Under voltage protection |
7.Three-phase unbalance protection | 8.Start timeout protection |
9.Jog timeout protection | 10.Underioad Protection |
11.Soft start overheating Protection | 11.Soft start overheating Protection |
13.Phase-to-phase short circuit Protection | 14.Ground Fault Protection |
15.Phase sequence protection | 16.Thyristor breakdown protection |
17.External fault protection | 18.Frequency protection |




Model | Overall dimension(mm) | Install dimension(mm) | Drawing | ||||||||
A | C | E | B | D | d | ||||||
75KW~115KW | 440 | 530 | 290 | 320 | 530 | M8 | 3 |

QUICK SETUP
thearameters related to the application and recommends tvpical settines. Yo can adjust each parameter according to your actual needs.Always set parameter A, the rated cul rent of the mptor to match the rated current indicated on the motor plate.The recommended valu is the minimum rated current of the starter
Feature List | Optional soft start curve | Adaptive control |
Constant current | ||
Current ramp | ||
Optional soft stop curve | Taxi stop | |
Timed voltage ramp soft stop | ||
Adaptive control | ||
Brake | ||
Extended input and output options | Remote control input (3 fifixed inputs, 2 programmable inputs) | |
Relay output (1 fifixed output, 3 programmable outputs) | ||
Analog output | ||
Built-in PT100 RTD input | ||
Optional expansion card | ||
Easy-to-read display shows comprehensive feedback | Removable operation panel | |
Multilingual feedback | ||
Event record with date and time stamp | ||
Working counter (starting times, running hours,kilowatt hours) | ||
Performance monitoring (current, voltage, power factor, kilowatt hours) | ||
User-programmable monitoring screen | ||
Customizable protection | Motor overload | |
Start-up timeout | ||
Under current | ||
Transient overcurrent | ||
Current imbalance | ||
Power frequency | ||
Input trip | ||
Motor thermistor | ||
Power circuit | ||
Phase sequence | ||
Models that meet all your connectivity needs | 23A-1600A (rated) | |
200VAC-440VAC | ||
380VAC-690VAC | ||
Internal bypass selection | ||
Star connection or delta connection | ||
Advanced application optional features | Input / output extension | |
RTD and ground fault protection | ||
DeviceNet, Modbus, Profifibus, Ethernet (Ethernet IP, Modbus TCP, Profifinet) or USB communication module |






We are pleasure to provide these to you for reference,you can cotact me,give me your emails ID.
Can you send me a sample?
It's my honor to send a sample to you,but you need to pay the sample fee and shipping cost
What's about your delivery time?
All type we have stock,after we receive payment,we will send you within two days.
How to pay it?
You can pay it to Alibaba,Paypal,bank.
How about your warrantly time?