| Max. input power(KW) | 12KW | 12KW | 13KW | 15.6KW |
| Max. DC voltage (V) | 500V | |||
| MPPT voltage range(V) | 120V-500V | |||
| Max.input current of single MPPT(A) | 12A | |||
| MAX. short circuit current(A) | 15A | |||
| Rated output power(KVA) | 7.6KV A | 8KVA | 10KV A | 12KV A |
| Max. output power(KVA) | 8.4KV A | 8.8KV A | 11KV A | 13.2KV A |
| Max. output current(A) | 36.3A | 38.3A | 47.8A | 57.4A |
| Ac output voltage(V) | 220V,230V,240V | |||
| Frequency(HZ) | 50HZ/60HZ(45~55,55~65) | |||
| PF | 0.8lagging-0.8leading | |||
| THDi | <2% | |||
| Rated power (KVA) | 7.6KV A | 8KVA | 10KV A | 12KV A |
| Rated output voltage(V) | 220V,230V,240V | |||
| Rated frequency(HZ) | 50/60HZ | |||
| THDu | <2% | |||
| Battery voltage range(V) | 40V~60V | |||
| Nominal voltage (V) | 48V | |||
| Max. charge/discharge current(A) | 190/190A | 190/190A | 210/210A | 250/250A |
| Battery type | lithium /Lead-acid | |||
| Charging strategy for Li-Ion battery | self-adaption to BMS | |||
| Grounding detection | YES |
| Arc fault protection | optional |
| Island protection | YES |
| Battery reverse polarity | YES |
| Insulation resistor detection | YES |
| Residual current monitoring unit | YES |
| Output over current protection | YES |
| Back-up output short protection | YES |
| Output over voltage/under voltage protection | YES |
| General data | |
| Europe efficiency (PV) | ≥97.8% |
MAX. battery to load effciency | ≥97.2% |
| Ingress protection | IP65 |
| Noise emission(DB) | <38dB |
| Operation temperature | '-25C~60C |
| Cooling | FAN cooling |
| Relative humidity | 0~95%(non-condensing) |
| Altitude | 2,000m (2,000De rating |
| Dimensions W *D *H (MM) | 430*220*710MM |
| Weight(KG) | 41KG |
| Display | LCD, Touch panel(optional) |
| Communication with BMS meter/EMS | RS485, CAN |
| Communication interface | RS485,WLAN,4G (optional) |
| Self-consumption at night | <2.5W(with battery enabling<5W) |
| Certificates | south Africa NRS, IEC62109-1/-2, IEC61000-6-1, IEC61000-6-3 |