AD series battery charger Ad-55 13.8V 13.4V 27.6V 26.5V Ad-155 13.8V 5V 13.3V 27.6V 27.1V 54V 53.5V AC to DC switching power supply
Features:
1.Voltage range 88~264VAC 124~370VDC
2. Protections: Short circuit / Overload / Over voltage / Over temperature
3. Working temperature -10 ~ +60ºC
4. Low cost, high reliability
5. 36 months warranty





| Model | AD-155A | AD-155B | AD-155C | |||
| Output Number | CH1 | CH2 | CH1 | CH2 | CH1 | CH2 |
| DC Voltage | 13.8V | 13.3V | 27.6V | 27.1V | 54V | 53.5V |
| Rated Current | 10.5A | 0.5A | 5A | 0.5A | 2.7A | 0.5A |
| Current Range | 0~11.5A | 0~0.5A | 0~5.5A | 0~0.5A | 0~2.7A | 0~0.5A |
| Rated Power | 151.55W | 151.55W | 156.5W | |||
| Ripple & Noise | 150mVp-p | ------ | 150mVp-p | ------ | 240mVp-p | ------ |
| Voltage Tolerance | ±2.0% | ------ | ±1.0% | ------ | ±1.0% | ------ |
| Line Regulation | ±0.5% | ------ | ±0.5% | ------ | ±0.5% | ------ |
| Load Regulation | ±0.5% | ------ | ±0.5% | ------ | ±0.5% | ------ |
| Setup, Rise Time | 1000ms,90ms/230VAC 2000ms,90ms/115VAC at full load | |||||
| Hold up Time | 24ms/230VAC 20ms/115VAC at full load | |||||
| Voltage Range | 88~264VAC 124~370VDC | |||||
| Frequency Range | 47~63Hz | |||||
| Efficiency | 80% | 84% | 84% | |||
| AC Current | 2.5A/115VAC 1.5A/230VAC | |||||
| Inrush Current | Cold start 23A/115VAC 45A/230VAC | |||||
| Over Load | CH1:105% ~ 135% CH2 : 0.51~0.9A rated output power | |||||
| Protection type : AC Charging Mode : Hiccup mode, recovers automatically after fault condition is removed UPS Mode : Protected by intemal fuse | ||||||
| Working Temp | -10 ~ +60ºC (Refer to "Derating Curve") | |||||
| Working Humidity | 20 ~ 90% RH non-condensing | |||||
| Storange Temp.,Humidity | -20 ~ +85ºC, 10 ~ 95% RH | |||||
| Temp Coefficient | ±0.03%/ºC (0 ~ 50ºC) | |||||
| Withstand Voltage | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | |||||
| lsolation Resistance | I/P-O/P, I/P-FG, O/P-FG :100M Ohms / 500VDC/25ºC/70% RH | |||||
| Dimension | 199*110*50mm | |||||
| Weight | 0.76Kg | |||||
| Model | AD-55A | AD-55B | ||
| Output Number | CH1 | CH2 | CH1 | CH2 |
| DC Voltage | 13.8V | 13.4V | 27.6V | 26.5V |
| Rated Current | 3.5A | 0.23A | 1.8A | 0.16A |
| Current Range | 0~4A | ------ | 0~2A | ------ |
| Rated Power | 51.38W | 53.92W | ||
| Ripple & Noise | 100mVp-p | ------ | 100mVp-p | ------ |
| Voltage Tolerance | ±1.0% | ------ | ±1.0% | ------ |
| Line Regulation | ±0.5% | ------ | ±0.5% | ------ |
| Load Regulation | ±0.5% | ------ | ±0.5% | ------ |
| Setup, Rise Time | 800ms,50ms/230VAC 1600ms,50ms/115VAC at full load | |||
| Hold up Time | 80ms/230VAC 16ms/115VAC at full load | |||
| Voltage Range | 88~264VAC 124~370VDC | |||
| Frequency Range | 47~63Hz | |||
| Efficiency | 71% | 74% | ||
| AC Current | 1.6A/115VAC 1A/230VAC | |||
| Inrush Current | Cold start 20A/115VAC 40A/230VAC | |||
| Over Load | 105% ~ 150% rated output power | |||
| Protection type : AC Charging Mode : Hiccup mode, recovers automatically after fault condition is removed UPS Mode : Protected by intemal fuse | ||||
| Working Temp | -10 ~ +60ºC (Refer to "Derating Curve") | |||
| Working Humidity | 20 ~ 90% RH non-condensing | |||
| Storange Temp.,Humidity | -20 ~ +85ºC, 10 ~ 95% RH | |||
| Temp Coefficient | ±0.03%/ºC (0 ~ 50ºC) on CH1 output | |||
| Withstand Voltage | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | |||
| lsolation Resistance | I/P-O/P, I/P-FG, O/P-FG :100M Ohms / 500VDC/25ºC/70% RH | |||
| Dimension | 159*97*38mm | |||
| Weight | 0.49Kg | |||





Q1:Are you a factory or trading company?
A1:We are factory.
Q2:Why choose us?
A2:Our factory has been in operation for 17 years,We have enough experience to meet your needs.
Q3:How can I get the samples?
A3:You can pay for the sample this time, and we will refund the sample fee for the next batch order.
Q4:How to order?
A4:Please contact us online to send you a proforma invoice or send us your purchase order by email.
Q5:How many years warranty of your switching power supply?
A5: Three years.








Audited Supplier