Aurora-12s 12.1-Inch Top Multi-Parameters Bedside Capnography ECG Vital Sign Patient Monitor for Hospital Supply with CE

Price $550.00 Compare
Min Order 10 pc
Availability In Stock
Shipping From Jiangsu, China
Popularity 419 people viewed
Quantity
+-
 

Jiangsu Konsung Bio-Medical Science and Technology Co., Ltd.

VIP   Audited Supplier 6 years
Profile Certified by SGS/BV
Aurora-12s
Customized
CE, ISO13485
12.1 Inch
800*600 Pixels
ABS+PC Fireproof Materials
Medical
8.9cm
110V/60Hz or 220V/50Hz
100V-240V~, 1.0-0.5A
ECG, NIBP, SpO2, Resp, Temp, Pr/Hr
Etco2, 2IBP, 12 LED ECG
Konsung
Carton
33cm*33cm*24cm
Danyang
9018193010
Product Description
Product Description
Semi-plug in design. Multiple parameter modules plug and use meet different monitoring needs quickly


There are warning, lamp flashing & tones alarm on patient monitor.



 It offers a comfortable experience because the design of thin, and the thickness is only 8.9cm.




Waterproof import from OMRON company life upon 1,000,000 times. (domestic less than 500,000 times)


Industrial shuttle imported from Japanese ALPS company working life upon 1,000,000 times (domestic less than 100,000 times)



Adopted by design of interface hidden with dust cover, it assures the clean of key parts.



Semi-plug in design. Multiple parameter modules plug and use meet different monitoring needs quickly.



24 kinds of ARR events including sinus arrhythmia, various forms of PVCs, VFIB, VTAC, AFIB, Asystole...


Three blocks, neat and reasonable layout inside, good anti-interference performance and easy maintenance.

3 - 8 rows of display adjustment


Optional Parts:


EtCO2
ETCO2 is the amount of carbon dioxide (CO2) in exhaled air, which assesses ventilation.
A high ETCO2 is a good sign of good ventilation, while low ETCO2 is bad sign that represents hypoventilation.


2IBP
With Template self-adapting technique, which ensure the accuracy in complicated clinic conditions. Solve the problem that NIBP of most brand patient monitor cannot measure stably and accurate when patients have arrhythmia and rapid changing pulse. The anocelia and intracranial will be monitored at same time.



Thermal Printer
Installed on the back of patient monitor, detachable.
Suitable to thermal paper.

Technique Parameters
Standard configuration
Screen
Display Type12.1" color TFT LCD
Resolution800×600 pixels
WaveformsUp to 7
ECG
Input3/5 wire ECG cable
Lead sectionI II III aVR, aVL, aVF, V
Gain selection*0.25, *0.5, *1, *1.2
Sweep speed6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s
Heart rate range15-30bpm
Calibration±1mv
Accuracy±1bpm or ±1% (select the bigger data)
NIBP
Test methodOscillometer
PhilosophyAdult, Pediatric and Neonate
Measurement typeSystolic Diastolic Mean
Measurement parameterAutomatic, Continuous measurement
Measurement method ManualmmHg or ±2%
SPO2
Display TypeWaveform, Data
Measurement range0-100%
Accuracy±3% (between 70%-100%)
Pulse rate range20-300bpm
Accuracy±1bpm or ±2% (select the bigger data)
Resolution1bpm
2-Temperature (Rectal & Surface)
Number of channels2 channels
Measurement range0-50ºC
Accuracy±0.2ºC
DisplayT1, T2, T
Unit ºC/ºF selection
Refresh cycle1s-2s
Respiration (Impedance & Nasal Tube)
Measurement type0-150rpm
Accuracy±1bm or ±5%, select the bigger data
Resolution1rpm
Optional configuration
EtCO2-Plug & Play
Measurement typeSide stream
Measurement range0-10.0%; 0-76mmHg
Accuracy<5.0%, ±0.28kPa; ±2mmHg
>5.0%, ±10%
2-IBP (optional)
Measurement range10~300mmHg
Number of channels1 or 2 channels
Accuracy±1mmHg or ±2%, select bigger data
Pressure tagART, CVT, RVP, LAP, RAP, PAP, ICP, LVP
12 leads ECG (optional)
Input3/5/10 wires ECG cable
Lead sectionI, II, III aVR, aVL, aVF, V(V1-V6)
Heart rate range15-380bpm
Calibration±1mv

FAQ
1.Can the accessories be exchanged between both Aurora and Aurora S series? 
Yes, it is possible to use the same accessories across both Aurora and Aurora S. 

2. Can the monitors display waveforms and numerical data? 
Yes, both monitors of Aurora and Aurora S can display waveforms and numerical data. 

3. How many waveforms can be displayed on the screen? 
The screen can display up to a maximum of 8 waveforms. 

4. Are the batteries a cost option? 
No, the battery is included in the basic price of the system. 

5. What types of batteries are used? 
Both systems use a high capacity built-in rechargeable lithium battery. 

6.Can the monitors connect to printer? 
Aurora series cannot connect to printer, and Aurora S series can connect to printer. 

7. Can the monitors support Wifi? 
Both of Aurora and Aurora S series can support to Wifi?   

8. Which kind of options parts can you offer? 
We can offer touch screen, IBP, 2IBP, EtcO2, Printer, wall mount and trolley.
  • Contact Supplier
Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA  
$6.00 1000 Pieces(MOQ)

Feline Test Kit for Fpv Fhv Fcv Antigens Rapid Test Kits Veterinary

Jiangsu Konsung Bio-Medical Science and Technology Co., Ltd.
$2000.00 1 Piece(MOQ)

Rapid Test Crp Pct Quantitative Time-Resolved Immunofluorescence Analyzer for Laboratory

Jiangsu Konsung Bio-Medical Science and Technology Co., Ltd.
$6.00 200 Pieces(MOQ)

Veterinary Cdv/Cpv/Ehr AG Combo Test Kits Rapid Diagnostic Test for Clinic

Jiangsu Konsung Bio-Medical Science and Technology Co., Ltd.
Negotiable 20 Pieces(MOQ)

Ksop-8 Portable Medical Impurity Intake Dust Air Air Filter for Oxygen Concentrator

Jiangsu Konsung Bio-Medical Science and Technology Co., Ltd.
$759.00 10 Pieces(MOQ)

Hospital Equipment Automatic Micro Intravenous Touch Screen Syringe Pump

Shenzhen Medrena Biotech Co., Ltd.
$1000.00 1 Piece(MOQ)

Healthcare Ric5-9-D Multi-Frequency Real-Time 4D Micro-Convex Ultrasound Transducer Probe Used

CWT TECHNOLOGY HK LIMITED
$1000.00 1 Piece(MOQ)

Internal Paddles 6.0cm Switched M4742A 989803109741 Mrx XL+ M4735A XL Defibrillator

CWT TECHNOLOGY HK LIMITED
$159.00 1 Piece(MOQ)

Sy-I060-1p Portable Home/Medical Use Oxygen Concentrator

GUANGZHOU SUNNYMED LIMITED
$2000.00 1 Piece(MOQ)

Hydraulic Gas Spring Transport Stretcher for Patient Medical Transfer Trolley From Factory

Hefei Spes Technology Co., Ltd
$999.00 1 Piece(MOQ)

Hospital Baby Care Equipment Mobile Infant Incubator

Guangdong Kangyu Medical Instrument Co., Ltd.