Model and specification | Explosion proof sign | Light source | Lamp type | Power (W) | Luminous flux (Lm) | Color temperature (K) | Weight (kg) |
BYS- | Ex db eb mb IIC T5 Gc Ex tb IIIC T80 Db | LED | I | 1x9 2x9 3x9 | 589 1165 1740 | 3000~5700 | 2.5 |
BCJ52- | AC380V | II | 1x18 2x18 3x18 | 1156 2312 3432 | 6 |
Rated voltage/frequency | Inlet thread | Cable outer diameter | Emergency charging time | Emergency starting time | Emergency lighting time | Degree of protection | Anti corrosion grade |
220V/50Hz | G3/4 | Φ7~Φ10mm | 24h | ≤0.3s | ≥90min | IP65/66 | WF2 |

2. Labyrinth structure is adopted for the shell, which is characterized by good dust-proof, waterproof and strong corrosion resistance;
3. The built-in ballast is a special explosion-proof ballast with a power factor ≥ 0.95. The built-in disconnecting switch automatically cuts off the power supply when the product is opened to improve the safety performance of the product; It also has short circuit and open circuit protection functions. It is equipped with prevention circuits for the aging effect and air leakage of the lamp tubes, so that the lamps can work normally, with high efficiency and energy saving. It has wide voltage input range, constant power output and other characteristics;
4. Equipped with well-known brand fluorescent tubes, with long service life and high luminous efficiency;
5. Emergency devices can be configured according to user requirements. When the external power is cut off, the lamps will automatically switch to the emergency lighting state;
6. Steel pipe or cable wiring is acceptable.
Applicable Scope: Zone 1, Zone 2, Zone 21,Zone 22;IIA, IIB,IIC Explosive Gas Environments
Security Level:WF2,Ex db eb mb IIC T5 Gc,Ex tb IIIC T80ºC Db
Field of utilization:Industry,Gas Station,Refinery,Spray Booth,Hazardous Locations
Alias:Explosion Proof Linear Light,Explosion Proof Fluorescent Light, Explosion Proof Strip Light,Explosion Proof Tube Light
Mounting Style:Bracket Type,Boom Type,Wall Type,Guardrail Type,Flange Type
Emergency Lighting Time:≥90min












2. It is applicable to the places in Zone 21 and 22 of combustible dust environment;
3. Suitable for IIA, IIB and IIC explosive gas environment;
4. Applicable to T1~T6 temperature groups;
5. It is applicable to work and scene lighting in dangerous environments such as petroleum exploitation, oil refining, chemical industry and gas station;
6. It is applicable to places with high protection requirements, humidity and corrosive gases.