2.Technical Specification:
- Rated Temperature: 850ºC
- Max. Temperature:1000ºC
- Chamber Dimensions: 600mm×600mm×600mm(D×W×H)
- Effective Dimensions: 400mm×400mm×400mm(D×W×H)
- Chamber Insulation Material: Aluminosilicate Ceramic Fiber
- Heating Elements: Resistance Coils in Ceramic Fiber Block
- Thermcouple: Type K
- Temperature Control Point: 4 Points
- Pre-Heating: 4 Inlets
- 3 Stages Pre-Filtering of air: 1- dust, 2 - water drops, 3 - oil vapor
- Temperature Control Precision≤ ±1ºC
- Temperature Control Mode: Temperature controller imported from Japan
- Heating-up Steps: Default 20 Steps
- Temperature Record: IPC makes a real-time sampling record of the chamber temperature and the gas heating temperature
- Heat-up Rate ≤6ºC/min
- Chamber Temperature Uniformity:400mm×400mm×400mm (D×W×H) area is better than ± 3ºC
- Furnace Surface Temperature ≤ RT+35ºC
- Lift System: the equipment lifting operation system adopts three-point control, automated hearth extension,which can be stopped at any time, with stable and reliable operation
- Maximum Lifting Trip: 800mm
- Loading Weight ≤ 150Kg ( including products and setters )
- Total Power: 52kW ( Max Heating Power:40kW, Max Gas Preheating Power:4×3kW )
- Outline Dimensions: 1520×1520×2250mm(D×W×H)
- Weight: about 1000kg

Item | Description | Qty | |
Basic Components | Furnace | 1SET | |
inspection certificate | Certificate of major outsourced components | 1SET | |
Technical Documents | Instructions, technical documents of the major outsourced parts, etc | 1SET | |
Key Components | Heating Elements | Resistance Coils Heating Plate | 1SET |
Flowmeter | Azbil/Dwyer/TOFCO/YINHUAN | 1SET | |
Differential Pressure | Dwyer/TOFCO/DUWEI | 1SET | |
Thermocouple | Watlow/THERMOWAY | 1SET | |
Lifting System | Customized | 1SET | |
Temp. Controller | Azbil | 1SET | |
PLC | SIEMENS | 1SET | |
Touch Screen | MCGS ( based on Linux) | 1SET | |
Spare Parts | Solid State Relay | XIMADEN | 1PC |
Heating Elements | Resistance Coils Heating Plate | 1 PC |
- Atmosphere Conditions: dry, clean, oil-free compressed air, working pressure of 0.2- 0.4MPa, gas consumption of 25-70 m3/h
- Environmental Conditions: temperature: 0~40ºC, humidity≤80%RH, no corrosive gas, no strong airflow disturbance
- Ventilation System: non-contact access to the user pumping system, pumping capacity is greater than 100 m3/h
- Ground Requirements: horizontal, no obvious vibration, load-bearing>500 kg/m2;
- Power: capacity> 70KVA, 3-phases 5-lines, voltage 220 / 380V, frequency 50Hz. Fire line: yellow, green, red, Zero line: blue, Ground line: yellow-green;
- Installation Site:3500mm×3000mm×3000mm(D×W×H), with an installation area greater than 11m2.