1310nm, and optionally 1550nm, are the most widely used fibers.
Performance Highlights
1.Wider wavelength range, suitable for high-speed network.
2. Accurate mode field diameter (MFD) characteristics ensure low splice loss and good compatibility.
Application scenarios
1. 100G and B100G high-speed long-distance long-span backbone network.
2. Large-bandwidth metropolitan area network and access network.
| characteristic | condition | unit | Numerical value |
| Optical properties |
| attenuation | 1310nm | dB/km | ≤ 0.350 |
1383nm | dB/km | ≤ 0.350 | |
1550nm | dB/km | ≤ 0.210 | |
1625nm | dB/km | ≤ 0.240 |
| Relative wavelength attenuation change | 1310nm VS. 1285-1330nm | dB/km | ≤ 0.04 |
1550nm VS. 1525-1575nm | dB/km | ≤ 0.03 |
| zero dispersion wavelength | nm | 1300 - 1324 |
| Zero dispersion slope | ps/(nm2·km) | 0.073 - 0.092 |
| Dispersion | 1550nm | ps/(nm·km) | 13.3 - 18.6 |
1625nm | ps/(nm·km) | 17.2 - 23.7 |
| Polarization Mode Dispersion Coefficient (PMD) | -- | ps/√km | ≤ 0.2 |
| Cable cut-off wavelength λcc | nm | ≤ 1260 |
| Mode Field Diameter (MFD) | 1310nm | μm | 9.2±0.4 |
| 1550nm | μm | 10.4±0.5 |
| decay discontinuity | 1310nm | dB | ≤ 0.03 |
| 1550nm | dB | ≤ 0.03 |
| Attenuated bidirectional end difference | 1310nm | dB/km | ≤ 0.04 |
| 1550nm | dB/km | ≤ 0.04 |
| geometric properties | ||
| Cladding diameter | μm | 125±0.7 |
| Cladding out-of-roundness | % | ≤ 1.0 |
| Core/Pack Concentricity Deviation | μm | ≤ 0.6 |
| Coating diameter | μm | 242±7 |
| Cladding/Coating Concentricity Deviation | μm | ≤ 12 |
| Warpage | m | ≥ 4 |
| Environmental characteristics (1550nm, 1625nm) | |||
| Temperature Cycling Additional Attenuation | -60ºC to +85ºC | dB/km | ≤ 0.03 |
| damp heat aging additional attenuation | 85ºC,RH85%,30 days | dB/km | ≤ 0.03 |
| Water immersion aging with additional attenuation | 23ºC,30 days | dB/km | ≤ 0.03 |
| Dry Heat Aging Additional Attenuation | 85ºC,30 days | dB/km | ≤ 0.03 |
| Mechanical properties | |||
| Tension Screening * | -- | GPa | |
kpsi | |||
| average value | peak | N | 1.3 - 8.9 |
| average value | N | 1.0 - 5.0 | |
| tensile strength | Weber probability 50% | GPa | ≥ 4.00 |
| Weber probability 15% | GPa | ≥ 3.20 | |
| Dynamic fatigue parameter Nd | -- | -- | ≥ 20 |
| macrobending loss | |||
| Ø60mm×100 turns | 1550nm | dB | ≤ 0.05 |
| 1625nm | dB | ≤ 0.05 | |
* Higher screening tension products are available | |||