1. Main Technical Data:
| System Usage: | Current Transformer Temperature-Rise Testing |
| Max.Output Current: | AC 4000A |
| Operation Model: | Continuous operation |
| Power Supply: | AC 220V±10%, 50Hz |
| Rated Capacity: | 30kVA |
| Control Model of the Testing Power: |
|
| Output Model of the High-Current: | Fixed Terminal Output |
| Time Control Function: | Provided |
| Power supply part: | ||||
| Iuput Voltage: | AC 220V±10%, 50Hz, Single-phase | |||
| Output voltage: | AC 0-250V, 50Hz, Single-phase | |||
| Rated capacity: | 30kVA | |||
| Rated current: | AC 120A | |||
| Power control part: | ||||
| Output Voltage model: | Coarse adjustment (30kVA) & Fine adjustment (0.5kVA) | |||
| Control Model of the Testing Power: | -Automatic adjustment by PC | |||
| -Simulation operation system | ||||
| -Manual adjustment (Up & Down of Coarse adjustment, Up & Down of Fine adjustment ) | ||||
| Regulatory Elements: | Double-servo motor and double voltage regulator | |||
| Other Part: | ||||
Display Function: | Output Voltage, Output Current | |||
| High-Current Display, AC 0-4000.0A, Resolution:0.1A, 0.2CL | ||||
| Timer, Display range:0.01H-99.99H | ||||
| Protection function: | Provides the overcurrent and overvoltage protection | |||
| Cooling: | Forced air cooling | |||
| Accessories: |
| |||
| Input Votlage: | AC 0-250V, 50Hz |
| Rated Capacity: | 20kVA |
Output Model of the High-Current: |
|
Product structure: |
|






Audited Supplier