DC 100 to 800A PV Circuit Breaker, PV Protector Solar Circuit Breaker

Price $500.00 Compare
Min Order 500 Pieces
Availability In Stock
Shipping From Zhejiang, China
Popularity 425 people viewed
Quantity
+-
 

Yueqing Yisi Electric Co., Ltd.

VIP   Audited Supplier 8 years
Profile Certified by SGS/BV
BAW5DC
Low Voltage Circuit Breakers
Electric Type
High-Speed Circuit Breaker
Air
Fixed
MCCB
3
Circuit Breaker
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection)
ISO9001-2000, CE, CB
PA66
V0
2p 3p
1000V 1500V
63-800A
TELEHAN
Carton Box
China
8536200000
Product Description
TELEHAN new generation DC 250V 500V 750V 1000V 1250V 1500V 100 to 800A PV circuit breaker, PV protector, PV mccb, solar breaker, dc MCCB, DC circuit breaker
Application:
BAW5DC series high-voltage circuit breakers (hereinafter referred to as circuit breakers) are used in DC power grid circuits with rated voltages of 800V, 1000V, 1500V, and rated operating currents of 63A to 800A. This circuit breaker has overload and short circuit instantaneous protection functions, used to distribute electrical energy and protect lines and power equipment from overload, short circuit, and other fault hazards.

Working Conditions and Installation:
Altitude:
The altitude of the installation site shall not exceed 2000m;

Ambient temperature:
The allowable ambient temperature is not higher than+70C and not lower than - 45C; (If the capacity is reduced by more than+40, the details must be negotiated with the manufacturer);

Atmospheric conditions
When the ambient temperature is 40C, the relative humidity of the atmosphere does not exceed 50%, and higher relative humidity is allowed at lower temperatures;
For example, 90% at 20C, taking into account the condensation on the product surface due to temperature changes;

Class of pollution: Class 3
Installation Category: III
Magnetic field for installation:
1, The magnetic field at the installation position shall not exceed 5 times than the geomagnetic field in any direction;
2, In a medium without explosion risk, and without gas and conductive dust sufficient to corrode metal and damage insulation;
3, Where there is no wind or snow erosion:

Installation conditions
Can be installed horizontally and vertically;
The installation site should be free of significant impact and vibration, and should not be installed in flammable and explosive places.

Technical Details:

 
ModelBAM5DC
Breaker Current Frame250315400630800
Rated Current(A) In63 80 100 125 140 160 180 200 225 250250 315 350 400400 500 630630 700 800
Rated Insulation Voltage(V) Ui1500V
Rated Impulse withstand Voltage(KV) Uimp 12
Rated Voltage(V)2P DesignDC250V DC500V DC100V DC1500VDC250V DC500V DC100V DC1500V
3P DesignDC1000V DC1250V DC1500VDC1000V DC1500V
Type of Electric DCPVDCPVDCPVDCPVDCPV
Rated Limit Short Current Breaking Capacity(KA) Icu2P Design15@DC1000V50@DC250 500V15@DC1000V50@DC250 500V25@DC250 500V50@DC250 500V25@DC250 500V50@DC250 500V25@DC250 500V50@DC250 500V
5@DC1500V25@DC750 1000V5@DC1500V25@DC750 1000V15@DC750 1000V25@DC750 1000V15@DC750 1000V25@DC750 1000V15@DC750 1000V25@DC750 1000V
 7.5@DC1500V 7.5@DC1500V10@DC1500V10@DC1500V10@DC1500V10@DC1500V10@DC1500V10@DC1500V
3P Design20@DC1500V25@DC750 1250V20@DC1500V25@DC750 1250V30@DC1000V40@DC1000V30@DC1000V40@DC1000V30@DC1000V40@DC1000V
 25@DC1500V 25@DC1500V25@DC1500V30@DC1500V25@DC1500V30@DC1500V25@DC1500V30@DC1500V
Rated Short Current Breaking Capacity(KA) Ics2P Design100% Icu
3P Design
Isolation FunctionYES
Using Cartegry Cat.A
Mechanism Life (times)2000010000
Electrical Life (times)1500800
Overview Dimension(mm)200*107*135310*182*156


BAM5DC WIRING DIAGRAM:







Overview and Installation Dimeansion:

Model&Spec.DISTANCE (MM)
ABCDEFGHIJ4-φd
BAM5DC-25030303030188138028094532-φ4.5
BAM5DC-315
BAM5DC-400303030301851350320118604-φ4.5
BAM5DC-630
BAM5DC-800



BAW5HU seriers MCCB installation section area:
Current(A)6380100125/140160180/200/225250280/300/315350/400500/630700/800
Section Area(mm2)16253550709520x520x5x240x540x840x5x2


 
Produnction Line Display:


Shippment  and Payment:


 
Brand Strategy:


  • Contact Supplier
Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA  
$5.20 2000 Meters(MOQ)

Fork/Pin Type Copper Bus Bar

Yueqing Yisi Electric Co., Ltd.
$15.00 20000 Meters(MOQ)

Drs Low Voltage Heat Shrink Sleeve, Heat Shrinkable Tubing, Heat Shrinable Tube, Thin Wall Heat Shrinkable Tubing, Insulation Tube

Yueqing Yisi Electric Co., Ltd.
$10.45 1500 Pieces(MOQ)

12/24/36kv Epoxy Resin Sensor/Capacitive Insulator/Cast Resin Insulator with Capacitive Sensor/Insulator Sensor

Yueqing Yisi Electric Co., Ltd.
$500.00 500 Pieces(MOQ)

DC 100 to 800A PV Circuit Breaker, PV Protector Solar Circuit Breaker

Yueqing Yisi Electric Co., Ltd.
$4500.00 1 Piece(MOQ)

Vs1-24 Type Indoor Vacuum Circuit Breaker with Embedded Poles Type Test Report

Jliamigo Electric Power (Yueqing) Co., Ltd.
$10000.00 1 Piece(MOQ)

Indoor Vacuum Circuit Breaker Parts for Vcb Manufacturer

Zhejiang Farady Powertech Co., Ltd.
$50.00 1 Piece(MOQ)

Vacuum Interrupter for indoor load breaking switch VTF31412C

Shaanxi Longxiang Electrical Co., Ltd.
$5.50 2 Pieces(MOQ)

4p 6ka 250V 500V 600V 800V 1000V 1A-63A Solar PV DC MCB Mini Circuit Breaker TUV IEC CE XL7

Zhejiang Leidun Electric Co., Ltd
$21.50 1 Piece(MOQ)

Single Magnetic Circuit Breaker Ndb1ts-63 MCB

Hefei Venus Technology Co., Ltd.
$0.60 1 Piece(MOQ)

Control and Thermal Overload Protection in Household Appliances and Circuit Boards Ksd-01f

CHANGZHOU CZSHINEMOTOR CO., LTD.