Dengue Rapid Test Diagnostic Kit of Ns1 Antigen or Igg/Igm Antibody Combo

Price $0.80 Compare
Min Order 5000 Pieces
Availability In Stock
Shipping From Guangdong, China
Popularity 307 people viewed
Quantity
+-
 

Dewei Medical Equipment Co., Ltd

VIP   Audited Supplier 3 years
Profile Certified by SGS/BV
DEN
IVD Reagent
Rapid Test + Buffer + Pipettes
Whole Blood, Serum, Plasma
Within 15 Mins
2~30 º C
24 Months
CE ISO
Dewei
40tests/Box
40tests/box
China
Product Description

INTENDED USE

The Dengue Rapid Test Cassette (Whole Blood/Serum/Plasma) is a rapid chromatographic immunoassay for the qualitative detection of IgG and IgM antibodies to Dengue virus in human whole blood, serum, or plasma as an aid in the diagnosis of primary and secondary Dengue infections.
 

Storage2~30 º C
SpecimenWhole Blood/Serum/Plasma
ComponentRapid Test + Buffer + Pipettes
PrincipleColloidal gold rapid tests
Reading Within 15mins
Package40tests/box
TrademarkDewei
OriginChina

 

INTRODUCTION

Dengue is a flavivirus, transmitted by Aedes aegypti and Aedes albopictus mosquitoes. It is widely distributed throughout the tropical and subtropical areas of the world,1 and causes up to 100 million infections annually. Classic Dengue infection is characterized by a sudden onset of fever, intense headache, myalgia, arthralgia and rash. Primary Dengue infection causes IgM antibodies to increase to a detectable level in 3 to 5 days after the onset of fever. IgM antibodies generally persist for 30 to 90 days. Most Dengue patients in endemic regions have secondary infections, resulting in high levels of specific IgG antibodies prior to or simultaneous with IgM response. Therefore, the detection of specific anti-Dengue IgM and IgG antibodies can also help to distinguish between primary and secondary infections.

The Dengue Rapid Test Device (Whole Blood/Serum/Plasma) is a rapid test that utilizes a combination of Dengue antigen coated colored particles for the detection of IgG and IgM Dengue antibodies in human whole blood, serum, or plasma.

 

MAIN CONTENTS

• A reaction test Cassette with desiccant.

• Buffer

• Disposable pipettes.

• Instructions for use.

 

STORAGE AND STABILITY

• Store at 2 ~ 30 º C in the sealed pouch for 24 months.

 

PRECAUTIONS

• For in vitro diagnostic use only.

• Do not use after expiration date.

• The test Cassette should remain in the sealed pouch until use.

• The used test Cassette should be discarded according to local regulations.

 

DIRECTION OF USE

Allow the test device, specimen, buffer, and/or controls to reach room temperature (15~30°C) prior to testing.

1. Bring the pouch to room temperature before opening. Remove the test device from the sealed pouch and use it as soon as possible.

2. Place the test device on a clean and level surface.

For Serum or Plasma Specimens:

Hold the dropper vertically, draw the specimen up to the Fill Line (approximately 5 uL), and transfer the specimen to the specimen well (S) of the test device, then add 3 drops of buffer (approximately 90 mL) and start the timer. See illustration below. Avoid trapping air bubbles in the specimen well (S).

For Whole Blood (Venipuncture/Fingerstick) Specimens:

To use a dropper: Hold the dropper vertically, draw the specimen 0.5-1 cm above the Fill Line, and transfer 1 drop of whole blood (approximately 10 µL) to the specimen well (S) of the test device, then add 3 drops of buffer (approximately 90 uL) and start the timer. See illustration below.

To use a micropipette: Pipette and dispense 10 µL of whole blood to the specimen well (S) of the test device, then add 3 drops of buffer (approximately 90 µL) and start the timer. See illustration below.

3. Wait for the colored line(s) to appear. Read results at 10 minutes. Do not interpret the result after 20 minutes.

INTERPRETATION

POSITIVE: Two colored bands appear on the membrane. One band appears in the control region (C) and another band appears in the test region (T).

NEGATIVE: Only one colored band appears, in the control region (C). No apparent colored band appears in the test region (T).

INVALID: Control band fails to appear. Results from any test which has not produced a control band at the specified read time must be discarded. Please review the procedure and repeat with a new test. If the problem persists, discontinue using the kit immediately and contact your local distributor.

PRODUCT IMAGES 


R&D TEAM

PRODUCTION LINE

CERTIFICATES

EXHIBITIONS 

SHIPMENTS 

 

  • Contact Supplier
Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA  
$1.50 5000 Pieces(MOQ)

Dewei Medical Rapid Test Cholera O1/O139 Combo Rapid Test

Dewei Medical Equipment Co., Ltd
$50.00 50 Sets(MOQ)

Hematology Analyzer Reagents on Sysmex Mindray Dymind Abx Horiba Nihon Kohden

Dewei Medical Equipment Co., Ltd
$0.60 5000 Pieces(MOQ)

Human Papilloma Virus (HPV) for Vaginal Swab Antigen Rapid Test Kit with CE

Dewei Medical Equipment Co., Ltd
$0.62 1000 Pieces(MOQ)

CE Prostate Specific Antigen (PSA) Rapid Test Kit Tumor Marker

Dewei Medical Equipment Co., Ltd
$1.50 500 Pieces(MOQ)

Hsv2 CE Herpes Simplex Virus 2 Igg Antibody Rapid Test Kits for Hospital Use

Evancare Medical ( Nantong) Co., Ltd.
$1.40 1000 Pieces(MOQ)

OEM Customized Home Safety Inspection High-Precision HIV Self Testing Kit

Jinqin (Beijing) Health Technology Co., Ltd
$6000.00 1 Unit(MOQ)

Kehua Biotech ST-960 Automatic ELISA Microplate Reader

Shanghai Kehua Bio-Engineering Co., Ltd.
$2.00 1000 Pieces(MOQ)

Testsealabs FLU A/B+C-19/MP+RSV/Adenp+HMPV Combo test kit

HangZhou Testsea biotechnology Co., Ltd.
Negotiable 3000 Pieces(MOQ)

Fast C-O-R-O-N-a 2019 Novel Virus Igg/Igm Antibody Test Kit

Jiangsu Medomics Medical Technology Co., Ltd.
$1.00 5000 Pieces(MOQ)

Home Used Human Immunodeficiency Virus (HIV 12) Aids Rapid Test Kit

Dewei Medical Equipment Co., Ltd