Model  | SUN-5K  -SG04LP3-EU | SUN-6K -SG04LP3-EU  | SUN-8K -SG04LP3-EU  | SUN-10K -SG04LP3-EU  | SUN-12K -SG04LP3-EU  | 
Battery Input Data  | |||||
Battery Type  | Lead-acid or Li-lon  | ||||
Battery Voltage Range (V)  | 40~60  | ||||
Max. Charging Current (A)  | 120  | 150  | 190  | 210  | 240  | 
Max. Discharging Current (A)  | 120  | 150  | 190  | 210  | 240  | 
External Temperature Sensor  | Yes  | ||||
Charging Curve  | 3 Stages / Equalization  | ||||
Charging Strategy for Li-Ion Battery  | Self-adaption to BMS  | ||||
PV String Input Data  | |||||
Max. DC Input Power (W)  | 6500  | 7800  | 10400  | 13000  | 15600  | 
Rated PV Input Voltage (V)  | 550 (160~800)  | ||||
Start-up Voltage (V)  | 160  | ||||
MPPT Voltage Range (V)  | 200-650  | ||||
Full Load DC Voltage Range (V)  | 350-650  | ||||
PV Input Current (A)  | 13+13  | 26+13  | |||
Max. PV ISC (A)  | 17+17  | 34+17  | |||
Number of MPPT / Strings per MPPT  | 2/1+1  | 2/2+1  | |||
AC Output Data  | |||||
Rated AC Output and UPS Power (W)  | 5000  | 6000  | 8000  | 10000  | 12000  | 
Max. AC Output Power (W)  | 5500  | 6600  | 8800  | 11000  | 13200  | 
AC Output Rated Current (A)  | 7.6  | 9.1  | 12.1  | 15.2  | 18.2  | 
Max. AC Current (A)  | 11.4  | 13.6  | 18.2  | 22.7  | 27.3  | 
Max. Continuous AC Passthrough (A)  | 45  | ||||
Peak Power (off grid)  | 2 time of rated power, 10 S  | ||||
Power Factor  | 0.8 leading to 0.8 lagging  | ||||
Output Frequency and Voltage  | 50/60Hz; 3L/N/PE 220/380, 230/400Vac  | ||||
Grid Type  | Three Phase  | ||||
DC injection current (mA)  | THD<3% (Linear load<1.5%)  | ||||
Protection  | |||||
PV Input Lightning Protection, Anti-islanding Protection, PV String Input Reverse Polarity Protection, Insulation Resistor Detection, Residual Current Monitoring Unit, Output Over Current Protection, Surge protection  | |||||
Certififications and Standards  | |||||
Grid Regulation  | CEI 0-21, VDE-AR-N 4105, NRS 097, IEC 62116, IEC 61727, G99, G98,  VDE 0126-1-1, RD 1699, C10-11  | ||||
Safety EMC / Standard  | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2  | ||||
General Data  | |||||
Operating Temperature Range (ºC)  | -45~60ºC, >45ºC derating  | ||||
Cooling  | Smrat cooling  | ||||
Noise (dB)  | <45 dB  | ||||
Communication with BMS  | RS485; CAN  | ||||
Weight (kg)  | 33.6  | ||||
Size (mm)  | 422W x 699.3H x279D  | ||||
Protection Degree  | IP65  | ||||
Installation Style  | Wall-mounted  | ||||
Warranty  | 5 years  | ||||



















  
  Audited Supplier
 