Load bank HS code: 9030899090
Electronic Load Bank Function and Features
1. The power density of RATAFE series electronic load is twice that of traditional load.
2. It has wider current range and extremely high dynamic frequency, which effectively increases the test ability and application range.
3. The powerful instantaneous overload capacity can reach more than 2 times of the rated power, which greatly improves the reliability of the load and effectively reduces the test cost.
4. It has rich working modes and adjustable slope of voltage and current.
Electrical Load Bank Application
1. RATA electronic load can be used for discharge test of power cell, lead-acid cell and fuel cell;
2. BMS and battery protection device test;
3. Test of power electronic devices such as DC charging pile and charging module;
4. High power switching power supply, UPS power supply, communication power supply,
5. Supply power supply test and solar cell array, industrial motor virtual load test.
Electronic Load Bank Specification
Model | Power | Voltage | Current | Model | Power | Voltage | Current |
RT2500-3U | RT5000-6U | ||||||
RT2500-28-80 | 2.5kW | 28 | 80 | RT5000-28-160 | 5kW | 28 | 160 |
RT2500-60-40 | 60 | 40 | RT5000-60-80 | 60 | 80 | ||
RT2500-80-30 | 80 | 30 | RT5000-80-60 | 80 | 60 | ||
RT2500-150-20 | 150 | 20 | RT5000-150-40 | 150 | 40 | ||
RT2500-300-10 | 300 | 10 | RT5000-300-20 | 300 | 20 | ||
RT2500-500-6 | 500 | 6 | RT5000-500-12 | 500 | 12 | ||
RT2500-600-5 | 600 | 5 | RT5000-600-10 | 600 | 10 | ||
RT2500-750-3 | 750 | 3 | RT5000-750-7 | 750 | 7 | ||
RT2500-1000-3 | 1000 | 3 | RT5000-1000-6 | 1000 | 6 | ||
RT7500-7U | RT10000-8U | ||||||
Model | Power | Voltage | Current | Model | Power | Voltage | Current |
RT7500-28-240 | 7.5kW | 28 | 240 | RT10000-28-320 | 10kW | 28 | 320 |
RT7500-60-120 | 60 | 120 | RT10000-60-160 | 60 | 160 | ||
RT7500-80-90 | 80 | 90 | RT10000-80-120 | 80 | 120 | ||
RT7500-150-60 | 150 | 60 | RT10000-150-80 | 150 | 80 | ||
RT7500-300-30 | 300 | 30 | RT10000-300-40 | 300 | 40 | ||
RT7500-500-18 | 500 | 18 | RT10000-500-24 | 500 | 24 | ||
RT7500-600-15 | 600 | 15 | RT10000-600-20 | 600 | 20 | ||
RT7500-750-10 | 750 | 10 | RT10000-750-14 | 750 | 14 | ||
RT7500-1000-8 | 1000 | 8 | RT10000-1000-12 | 1000 | 12 | ||
RT15000-10U | RT24000-13U | ||||||
RT15000-28-480 | 15kW | 28 | 480 | RT24000-28-770 | 24kW | 28 | 770 |
RT15000-60-240 | 60 | 240 | RT24000-60-390 | 60 | 390 | ||
RT15000-80-180 | 80 | 180 | RT24000-80-300 | 80 | 300 | ||
RT15000-150-120 | 150 | 120 | RT24000-150-200 | 150 | 200 | ||
RT15000-300-60 | 300 | 60 | RT24000-300-96 | 300 | 96 | ||
RT15000-500-36 | 500 | 36 | RT24000-500-60 | 500 | 60 | ||
RT15000-600-30 | 600 | 30 | RT24000-600-48 | 600 | 48 | ||
RT15000-750-20 | 750 | 20 | RT24000-750-35 | 750 | 35 | ||
RT15000-1000-16 | 1000 | 16 | RT24000-1000-30 | 1000 | 30 |
Note: all parameters are for reference only and can be customized | ||
Voltage | According to customer needs | |
Current | According to customer needs | |
Power | According to customer needs | |
Current Resolving power | 1.4mA | 14mA |
Current Accuracy | 0.05% + 0.05% F.S. | |
Voltage Resolving power | 2mV | 10mV |
Voltage Accuracy | 0.025% + 0.025% F.S. | |
Resistance Range | 0.015Ω~2kΩ | |
Resistance Accuracy | Vin divided by RSET multiplied by (0.2%) plus 0.2% F.S. | |
Power Accuracy | 0.2% plus 0.2% F.S. | |
T1&T2 | 10us~60s | |
Resolving power | 2us | |
Power Accuracy | 1us + 20PPM | |
Gradient | 1mA/us~8A/us | |
Rated voltage | AC 220V | |
Rated frequency | 50~60Hz | |
Temperature | 0-50ºC |