Electronic Motor Over Current Protector

Price $8.15 Compare
Min Order 500 Pieces
Availability In Stock
Shipping From Zhejiang, China
Popularity 477 people viewed
Quantity
+-
 

Yueqing Long Road Electric Co., Ltd.

VIP   Audited Supplier 18 years
Profile Certified by SGS/BV
HTHY-21
Motor Overcurrent Protector
Electronic Type
Overcurrent Protecting Relay
Relay
DIN-Rail
Electronic
Relay
Overcurrent Protection, Phase Loss and Phase Failure and Locked Rotor
ISO9001-2000, CE, CB, CCC
6A,30A,60A
90~260VAC
05, 30, 60
180~440VAC
LONGROAD/OEM
Exporting Carton
China
Product Description
Product Generalizes:
   HTHY-21 Motor Overcurrent Electronic Protector is a super small overcurrent relay with definite time action characteristics. Using the main circuit phase line to pass through two transformers (CTs) to obtain the current sensing signal. When the load is abnormal, cut off the power supply of the control circuit through the action of the internal relay to protect the load. The utility model has the advantages of small size, light weight, anti-interference, noiseless, reliable performance, strong protection function,
convenient installation and use, etc. It is mainly applicable to overload protection of motors, equipment, etc.
  1.Function introduction:
  1.1 It has overcurrent, phase loss, locked rotor protection functions.
  1.2. Three different models (05, 30, 60) can be used to achieve protection in the range of 0.5~60A.
If it exceeds 60A (maximum 800A), external transformer shall be used together.
  1.3. Start delay, action delay and overload values can be set separately.
  1.4. The working power supply are single phase 90~260VAC, three phase 180~440VAC, (24V, 36V,
110V, 660V power supply can be customized for production).
  1.5. The two indicator lights (LED) respectively display the power status (green) and action status
(red).
  1.6. After the relay acts, it can be reset manually (press RESET button) and by power off.
  1.7. This product has three different current models 05(0.5-6A), 30(3.0~30A),60(5.0~60A)
  2.Setting method
  After the wiring is completed according to the typical wiring diagram, the relay shall be set as
necessary to ensure the normal operation of the relay. The methods are as follows:
  2.1 Before starting the motor, according to the actual starting time of the motor, set the D-TIME knob
to this value (it is better to add 2~3 seconds more). If it cannot be determined, set the knob to the
maximum value.
  2.2 Adjust the action delay knob (O-TIME) and overcurrent setting knob (LOAD) to the maximum
value.
  2.3 Start the motor, and after the motor runs stably (i.e. exceeding the D-TIME value of the starting
delay time), slowly turn the overcurrent setting (LOAD) counterclockwise until the red indicator light (LED) lights up, which is 100% of the actual running current value. Then turn the knob clockwise to the point where the red indicator just went out (within the setting time of the action delay O-TIME). This point is 103% of the actual operating current value. Continue to turn the overcurrent setting button (LOAD) clockwise to set it at a proper overcurrent value. (The recommended over-current value is between 110% and 125% of the actual operating current value)
  2.4 Recalibrate the starting delay time (D-TIME) according to the normal starting operation of the
motor. Generally, the set value is 2~3 seconds larger than the actual value.
  2.5 Reset the action delay (O-TIME) time according to the actual situation.
  2.6 After setting, press TEST button to check the setting result
  3. Indicator status description
  3.1 When the relay is powered on, the green indicator (LED) lights up, indicating that it has entered
the normal state.
  3.2 If the red indicator light is on during operation, it means that the protection function of the relay acts.
Rated Current6A,30A,60A
working power supply are single phase90~260VAC
working power supply are three phase180~440VAC
models180~440VAC
  4.Instructions for using the test button
The relay shall be tested regularly during operation. The method is as follows: Under no load
condition, press the test button (TEST) and do not let go.
The red indicator is on. After the start delay and action delay time, a relay action sound of "Da" can
be heard. At this time, release the test button (TEST), and the red indicator light is always on, indicating that the relay is working normally. After completing the above work, press the RESET button to reset and enter the normal working state.
 
5. Wiring diagram
6.Installation Dimensions
 



generalizesgeneralizesgeneralizes
  • Contact Supplier
Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA  
Negotiable 500 Pieces(MOQ)

Tgymb-Ii Type Fireproof Plastic Single Phase Prepaid Meter Box (TGYMB-II)

Yueqing Long Road Electric Co., Ltd.
$9.07 2 Pieces(MOQ)

Mini Automatic Transfer Dual Power Supply 4p 10A~125A ATS

Yueqing Long Road Electric Co., Ltd.
Negotiable 500 Pieces(MOQ)

Motor Phase Failure&Phase Sequence&Over-Voltage&Under-Voltage Protective Relay

Yueqing Long Road Electric Co., Ltd.
$0.80 1000 Pieces(MOQ)

Moulded Case Circuit Breaker Srb5-63

Yueqing Long Road Electric Co., Ltd.
$6.58 100 Pieces(MOQ)

3p 16A 20A 25A 32A 50A 63A RCBO Leakage Miniature Circuit Breaker

Paiya Intelligent Electric Appliance (Yueqing) Co., Ltd.
Negotiable 2 Pieces(MOQ)

Acb 1140V 2500A 3p/4p Customizable Fixed Withdrawable High Voltage Air Circuit Breaker

Zhejiang Leidun Electric Co., Ltd
$2000.00 1 Piece(MOQ)

Single Phase Pole Mounted Vacuum Circuit Recloser ACR

Jliamigo Electric Power (Yueqing) Co., Ltd.
$622.00 1 Piece(MOQ)

Molded Case Disconnecting Switch Ndm3g-250/250V/400/400V/630/800

Hefei Venus Technology Co., Ltd.
$1500.00 5 Pieces(MOQ)

630A 12kv Vcb Panel Drawer Handcart Vacuum Circuit Breaker

Zhejiang Xianghu Technology Co., Ltd.
$0.16 10 Pieces(MOQ)

MCB Solenoid Tripping System (XMC45M-19) Circuit Breaker Spare Parts

Zhejiang Ximu Intelligent Technology Co., Ltd.