We have 10000 square meter production workshop, could produce more than 3000T per year all kinds of steel structure products, including envrionmental protection products, like ESP, various of silo, stock bin, water bin, cyclone dust removal equipment, steel chiminey etc.;








| N0. | Item | Specification | Material | Unit | Quantity |
| , Duct system | |||||
| 1.1 System Inlet duct | |||||
| 1 | High temperature duct | φ2300×6mm,35m | Q355 | t | 17 |
| 2 | Low temperature duct | φ2000×6mm,15m | Q235B | t | 6.5 |
| 3 | By-pass duct | φ2600×6mm,30m | 15CrMoV | t | 16.5 |
| 4 | De-sox by-pass duct | φ2300×6mm,10m | Q355 | t | 5 |
| 5 | High temperature heat exchanger inlet duct | φ2600×6mm,10m | 15CrMoV | t | 5.5 |
| 6 | Heat exchanger cold air duct | φ2000×6mm,20m | Q235B | t | 8.5 |
| 7 | High temperature heat exchanger | Hot side:Flue gas volume 95000Nm³,inlet temperature 550ºC, exit 360ºC,resistance<300pa cold side: air 20ºC Blade material :304 1mm | set | 1 | |
| 8 | Low temperature heat exchanger | Hot side:Flue gas volume 95000Nm³,inlet temperature 360ºC,exit 200ºC,resistance<450pa cold side: air 20ºC Blade material:NDsteel: 1.5mm | set | 1 | |
| 9 | High temperature heat exchanger fan | Flow 73601m³/h, Static pressure 461pa,total pressure 709pa,frequency conversion, Medium normal temperature air | Piece | 2 | |
| 10 | Low temperature heat exchanger fan | Flow 73601m³/h,Static pressure 399pa,total pressure 709pa,frequency conversion, Medium normal temperature air | Piece | 2 | |
| 11 | Duct bracket | Q235B | t | 30 | |
| 12 | Manhole gate | 600×800, double layer | Q355 | Piece | 2 |
| 13 | Metal expansion joint | φ2300(Inner Diameter),(welded),(axial direction)80,(Radial direction )20,2mm | 304 | Piece | 2 |
| 14 | Metal expansion joint | φ2600(Inner Diameter),(welded),(axial direction)80,(Radial direction)20,2mm | 304 | Piece | 2 |
| 15 | System bypass electric baffle door | φ2600,(overturn type),(Flue gas temperature)550ºC,(withstand voltage)±5000pa,(switching mode),(including the local operation) | 15CrMoV | Piece | 1 |
| 16 | De-sox bypass flue baffle door | φ2300,(overturn type),(Flue gas temperature)390ºC,(withstand voltage)±5000pa,(switching mode), (including the local operation) | Q355 | Piece | 1 |
| 17 | High temperature heat exchanger inlet baffle door | φ2600,(overturn type),(Flue gas temperature)550ºC,(withstand voltage)±5000pa,(switching mode),(including the local operation) | 15CrMoV | Piece | 1 |
| 18 | High temperature heat exchanger exit baffle door | φ2300,(overturn type),(Flue gas temperature)390ºC,(withstand voltage)±5000pa,(switching mode),(including the local operation) | Q355 | Piece | 1 |
| 19 | Low temperature heat exchanger inlet baffle door | φ2300,(overturn type),(Flue gas temperature))390ºC,(withstand voltage)±5000pa,(switching mode),(including the local operation) | Q355 | Piece | 1 |
| 20 | Low temperature heat exchanger exit baffle door | φ2000,(overturn type),(Flue gas temperature)350ºC,(withstand voltage)±5000pa,(switching mode),(including the local operation) | Q355 | Piece | 1 |
| 21 | Induced draft fan inlet baffle door | φ2000,(overturn type),(Flue gas temperature)550ºC,(withstand voltage)±5000pa,(switching mode),(including the local operation) | 15CrMoV | Piece | 2 |
| 22 | Induced draft fan outlet baffle door | φ2000,(overturn type),(Flue gas temperature)550ºC,(withstand voltage)±5000pa,(switching mode),(including the local operation) | 15CrMoV | Piece | 2 |
| 23 | De-sox system inlet baffle door | φ2300,(overturn type),(Flue gas temperature)390ºC,(withstand voltage)±5000pa,(switching mode),(including the local operation) | Q355 | Piece | 1 |








Audited Supplier