EPCZ Series Variable Frequency AC Resonance Test System
EPCZ Series AC Resonance Test System is specially designed for AC withstand test for electric equipments of substation at 10kV~500kV or below.
Applications:
- Transformer
- Cables
- GIS System
- Insulator
- CT/PT
- Generator
- Other electric devices
Features:
- Small size, portable for operating.
- Screen to show the test data, status and display operation step by real-time.
- Small temperature rising at rated load. Dry-type epoxy cast, high mechanical strength and good insulation ability.
- 220V or 380V single phase power source is suitable for on-site sourcing.
- Different type reactors for optional realize the multipurpose.
- With over current, over voltage, IPM and discharge protection function.
- Test result can be printed.
Rated output voltage: 0~500kV or below
Output frequency: 20 -300Hz.
Resonant voltage waveform: sine wave, waveform Distortion rate ≤ 1%.
Full load working time: continuous working time 60mins.
Quality factor: max. load ≥ 20.
Frequency adjustment: fineness 0.1Hz, instability ≤ 0.01%.
Power supply: 220V or 380V single-phase.
Common Configuration:
Model | Test Object | Main Configurations: | |||
AC power source | Exciting Transformer | Reactor | Capacitive Voltage Divider: | ||
EPCZ-27/54/108-108 Test Frequency: 20~300Hz | 31500kVA/35kV Power Transformer | 10KW 1 unit | 10KW 1 unit | 27kV/1A 4 Units Frequency: 20-300Hz | 120kV |
35kV circuit breaker, busbar, insulator | |||||
10kV(300mm2) cable 2000m | |||||
35kV(300mm2) cable 500m | |||||
EPCZ-54/108/216-216 Test Frequency: 20~300Hz | 110kV Circuit breaker and busbar | 15kW 1 unit | 15kW 1 unit | 54kV/1A 4 Units Frequency: 20-300Hz | |
110kV GIS ≤ 10 intervals | |||||
35kV (300mm2) cable 1500m | |||||
10kV (300mm2) cable 3000m | |||||
110kV Full Insulated Transformer | |||||
EPCZ-65/130/260-520 Test Frequency: 20~300Hz | 110kV Circuit Breaker and busbar | 30kW 1 Unit | 30kW 1 Unit | 65kV/2A 4 Units Frequency: 20-300Hz | 300kV |
110kV GIS ≤ 10 intervals | |||||
110kV (300mm2) cable 800m | |||||
35kV (300mm2) cable 3000m | |||||
10kV(300mm2) cable 200m | |||||
110kV Full Insulated Transformer | |||||
EPCZ-45/90/135/180/270-270 Test Frequency: 20~300Hz | 110kV Insulator, switchgear, GIS and etc. | 20kW 1 unit | 20kW 1 unit | 45kV/1A Six Units Frequency: 20-300Hz | 200kV |
50MW/110kV Full Insulated Transformer | |||||
110kV (300mm2) cable 200m | |||||
35kV Power Transformer, switchgear, CT/PT, cable, etc. | |||||
20MW hydrogenator | |||||
10kV power transformer, switchgear, CT/PT, cables etc. | |||||
EPCZ18/36/54 Test Frequency: 20~300Hz | 10kV (300mm2) cable 2000m | 5kW 1 Unit | 5kW 1 unit | 27kV/1A 2 units or 18kV/1A 3 units Frequency: 20-300Hz | 60kV |
35kV (300mm2) cable 500m | |||||
10kV power transformer, switchgear, CT/PT etc. |
Note:
- Model EPCZ-27/54/108-108, EPCZ is the model of series, 27/54/108 is: voltage of one reactor (kV)/voltage of two reactors in series connection/voltage of four reactors in series connection. 108 is the total capacity (kVA).
- The test object is the common configuration for reference only. For details, please contact with us.
- If the capacity of your equipment is small and voltage is too low, can add more reactors to increase the capacity, and add more divider to increase the test voltage.