Good Factory Prices Silent Diesel Generator 100kVA 150kVA 200kVA Power Generation

Price $11000.00 Compare
Min Order 1 set
Availability In Stock
Shipping From Fujian, China
Popularity 280 people viewed
Quantity
+-
 

Fuzhou Genspark Equipment Co., Ltd.

VIP   Audited Supplier 4 years
Profile Certified by SGS/BV
GF/GFS-C120KW
1 Year/1200 Hours
1 Year/1200 Hours
Basic Diesel Generator
Fixed
Four Stroke
Water Cooling
AC Three Phase
Speed
Land Use
Common Units, Standby Unit, Emergency Crew
Automation Type
AC Rotating Exciter
6BTA5.9-G2
Leroy Somer or Equivalent
Open Type/Silent Type/Trailer Type/Container Type
8-9 Hous Fuel Tank
Comap/Smartgen/Deepsea
Installing with ATS
Depends
60Hz
220V/127V 3 Phase
Gspark
Wooden Package
7CBM
Fujian
8502
Product Description
Brief introduction:  Genspark Equipment Co.,Ltd mainly Supply Diesel Generator Set and Gas Generator set,including in Famous brands,Deutz,Doosan,MTU,ShangHai Diesel,YangDong etc,raning from 10KW-2000KW Outputs.Having Open type,Silent type,Container type and trailer type generator models.

With more than 10 years experience on supplying Generator sets,We always offer Most Suitable Products for Customers Abroad.












 





 
60Hz Diesel Generator with Cummins Power
 
Generator Set PerformanceEngine SpecificationSoundproof type
Genset Model60Hz OutputEngine ModelPower(Kw)Fuel Comsuption(100% Load)DimensionWeight
60HzPrime StandbyKWL/HL*W*H(mm)KG
KVAKWKVAKW
GF/GFS-C2727.52232.5264B3.9-G1/G22761950*830*11001250
GF/GFS-C37373041334BT3.9-G1/G24082200*950*12001350
GF/GFS-C4342.53447374BT3.9-G1/G24082200*950*12001350
GF/GFS-C60604866534BTA3.9-G2609.82400*950*13601450
GF/GFS-C68685575604BTA3.9-G260132400*950*13601450
GF/GFS-C85856894756BT5.9-G1/G292-102232700*1100*14501800
GF/GFS-C10010080110886BT5.9-G1/G292-102232700*1100*14501850
GF/GFS-C11310080110886BT5.9-G1/G292-102232700*1100*14501900
GF/GFS-C1251251001371106BTA5.9-G2120232700*1100*14502000
GF/GFS-C1371381101511216BTA5.9-G2120232800*1150*15602100
GF/GFS-C1501501201651326BTAA5.9-G2132262800*1150*15602150
GF/GFS-C1801801441981586CTA8.3-G218033.93100*1100*15102350
GF/GFS-C1871871502061656CTA8.3-G218035.13100*1100*15102400
GF/GFS-C2252251802481986CTAA8.3-G220138.73300*1150*18002550
GF/GFS-C2502502002752206LTAA8.9-G224038.73300*1150*18002700
GF/GFS-C2752752203032436LTAA8.9-G224038.73300*1150*18002750
 




























-------------------------------- -----------------------------------------------------After-Sale Part------------------------------------------------------------------------------------
Helpful tips on Generator Set Fault
When fault occurs during generator set running,could do primary judgement according to following tips.
IconIndicator LightReasonFault Analysis and Solve Method
High Water Temperature AlarmHigh Water Temperature AlarmWhen water Temperature has risen to a level higher than or equal to the sensor setting,the light is on.Normally,it is caused by lack of Water or Oil Shortage,or Overload. ----Should Automatically Shutdown Generator set Immediately.
Low Oil Pressure AlarmLow Oil Pressure AlarmWhen water Temperature has risen to a level higher than or equal to the sensor setting,the light is on.Normally,it is because of lack of Oil or Lubrication System Failure which caused by refueling or replacing the Oil Filter.----- When occurs this fault,should automatically shutdown generator set immediately.
Low Fuel Level AlarmLow Fuel Level AlarmWhen Fuel level has been detected by sensor fitted to the daily tank,the light is off.Normally,it caused by lacking of Water or Oil Shortage,or Overload.-----When occures this Fault,should automatically shutdown Generator set Immediately.
Battery Charger Fault AlarmBattery Charger Fault AlarmThe Charing System has fault while engine still running,the light is off.Battery Charging System Fault Caused.---The light in on at the initial Start,when the charger reaches a certain speed,the light is off.---This Failure will not lead to Automatic Shutdown Generating Unit.
Crank Failure AlarmCrank Failure AlarmWhen Generator set fail three times(or six times) in arow starting,the light is onIt is caused by Oil Supply System or Re-Start System Failure.
Overload or Breaker Tripping AlarmOverload or Breaker Tripping AlarmWhen Overloading or Short Circuit,the light is on. Tripping Circuit Breaker cause generator set load out.For this fault,it needs to load or unload some parts to eliminate short-Circuit,and then re-close the circuit Breaker.


 










  • Contact Supplier
Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA  
$4800.00 1 set(MOQ)

50Hz 380V 3 Phase Open Frame Deutz Power Air Cooled Diesel Geneator 38kVA

Fuzhou Genspark Equipment Co., Ltd.
$95700.00 1 set(MOQ)

60Hz 440V 3 Phase Soundproof Diesel Generator Set 375kVA with ATS Automatic Transfer

Fuzhou Genspark Equipment Co., Ltd.
$105000.00 1 set(MOQ)

Standby Power Weichai Baudouine Engnine Soundproof 1MW Diesel Generator

Fuzhou Genspark Equipment Co., Ltd.
$11000.00 1 set(MOQ)

Good Factory Prices Silent Diesel Generator 100kVA 150kVA 200kVA Power Generation

Fuzhou Genspark Equipment Co., Ltd.
$85000.00 1 Piece(MOQ)

Auto Synchronization System Silent Power Generator with Optimally Designed

Jiangsu xinhuazhong automatic equipment Co.,Ltd
$130000.00 1 set(MOQ)

Brand New Cat 50Hz Standby 780kVA Caterpillar C18 Engine Diesel Power Generator Set

Fujian Sutong Power Technology Co., Ltd.
$85400.00 1 Piece(MOQ)

1000kw 1250kVA Low Fuel Consumption Generator Set with Famous Yuchai Engine

Shandong Supermaly Generating Equipment Co., Ltd
$11199.00 1 Piece(MOQ)

DELLENT : OEM Factory Price 188kVA Cummis 6CTA8.3-G2 Power Generator Customizable OPEN/SLIENT Diesel Generator Set

Fuan Dellent Electric & Machinery Co., Ltd.
Negotiable 1 Piece(MOQ)

250kw Generator Without Diesel Engine, Stamford Technology, with Double Bearings

Kanpor Electrical Machinery Co., Ltd.
$15000.00 1 Piece(MOQ)

High Voltage Volvo 110kw 140kVA Diesel Power Generator with Durable Enclosed Frame Silent Canopy

Baifa Power (Wuxi) Ltd.