DC Leakage Current Sensor
A new type of current sensor developed by applying the principle of magnetic modulation. The primary current is compensated by the current generated by the internal oscillator to achieve the balance of the magnetic field. At this time, the secondary voltage can accurately reflect the primary current.
Product Features
Small current measurement performance is stable
Excellent accuracy, good linearity
Wide measuring range and strong overload capacity
Perforated structure, no insertion loss
Scope of Application
The signal system
Line detection
Leakage Monitoring System
Current difference measurement
Technical Parameter | |||||
Specification | 10mA/5V | 50mA/5V | 200mA/5V | Unit | |
IPN | Primary Rated Input Current (DC) | 10 | 50 | 200 | mA |
IP | Primary Current Measurement Range | 0~15 | 0~75 | 0~300 | mA |
VSN | Secondary rated output voltage(DC) | 5 | V | ||
VC | The Power Supply Voltage | ±12~15(±5%) | V | ||
IC | Current Consumption | <30 | mA | ||
Vd | Insulation Voltage | Between primary and secondary circuits:2.5kV/50Hz/1min | |||
εL | Linearity | <1 | %FS | ||
X | Precision | TA=25ºC:≤±0.5 | % | ||
V0 | Offset Voltage | TA=25ºC:≤±50 | mV | ||
VOT | Offset Voltage Temperature Drift | Ip =0 TA =-40~+80ºC:≤±1.5 | mV/ºC | ||
Tr | Response Time | ≤120 | mS | ||
TA | Working Temperature | -40~+80 | ºC | ||
TS | Storage Temperature | -45~+85 | ºC | ||
RL | Load Resistance | TA=25ºC:≥10 | kΩ |
Can be made according to user requirementsProduct dimensions


+ :Positive 12V/15V power supply
- :Negative 12V/15V power supply
M :Secondary signal output
G :Power ground
OFS:Zero adjustment